

Add to Cart
Product Description
This electro-proportional, direct-acting reducer/reliever valve
reduces a high primary pressure at the inlet (port 2) to a constant
reduced pressure at port 1, with a full flow relief function from
port 1 to tank (port 3). The valve is biased to the relieving mode.
Energizing the coil connects port 2 to port 1. Increasing the
current to the coil will proportionally increase the reduced
pressure at port 1. If pressure at port 1 exceeds the setting
induced by the coil, pressure at port 1 is relieved to port 3. This
valve is closed in the transition between reducing and relieving
resulting in very low consumption of oil. Optional full manual
control is available.Maximum pressure at port 3 should be limited
to 3000 psi (210 bar).
Pressure at port 3 is directly additive to the valve setting at a
1:1 ratio and should not exceed 3000 psi (210 bar).Leakage
specified in Technical Data is out of port 3 with a supply pressure
of 2000 psi (140 bar) and the valve set at mid range. This leakage
is directly proportional to pressure differential and inversely
proportional to viscosity expressed in centistokes.The transition
from reducing to relieving is closed. The result is very low
leakage. However, there is a transitional step increase in pressure
between reducing and relieving modes. This step equals about 5% of
the high end of the adjustment range, independent of the valve
setting.
For optimum performance, an amplifier with current sensing and
adjustable dither should be used. Dither should be adjustable
between 100 - 250 Hz.Handknob control for this valve is available
in kit form only and can not be ordered from the factory in this
configuration. See kits 991-211 and 991-034.NOTE: There is no upper
limit to the pressure setting when using the M control. The more
force you exert on the manual override, the higher the resulting
pressure.The 'E' manual control assembly has a mechanical life
expectancy of approximately 7,000 cycles.The momentary/twist
override option "E" allows the operator to shift the valve by
twisting the manual override clockwise 90 degrees.
Cartridges configured with EPDM seals are for use in systems with
phosphate ester fluids. Exposure to petroleum based fluids, greases
and lubricants will damage the seals.Suitable for accumulator
circuits since the absence of pilot control flow results in reduced
secondary circuit leakage.
Direct acting concept provides highly reliable operation in
contaminated systems, especially at dead headed conditions.All
three-port pressure reducing and reducing/relieving cartridges are
physically interchangeable (i.e. same flow path, same cavity for a
given frame size). When considering mounting configurations, it is
sometimes recommended that a full capacity return line (port 3) be
used with reducing/relieving cartridges.
Brand | SUN |
Model | PRDP-MDN |
Solenoid Tube Diameter | 75 in. |
Valve Hex Size | 7/8 in. |
Valve Installation Torque | 30 - 35 lbf ft |
Adjustment Screw Internal Hex Size | 5/32 in. |
Locknut Hex Size | 9/16 in. |
Locknut Torque | 80 - 90 lbf in. |
Model Weight (with coil) | 1.20 lb |
Model Weight | 0.73 lb. |
FAQ
Q1: Wonder if you accept small orders?
A1: Do not worry. Feel free to contact us .in order to get more
orders and give our clients more convener ,we accept small order.
Q2: Can you send products to my country?
A2: Sure, we can. If you do not have your own ship forwarder, we
can help you.
Q3: What's your payment terms ?
A3: By T/T,LC AT SIGHT,100% full payment.
Q4: How long is your production lead time?
A4:It depends on product and order qty. Normally, it takes us 15
days for an order with MOQ qty.
Q5: When can I get the quotation ?
A5: We usually quote you within 24 hours after we get your inquiry.
If you are very urgent to get the quotation.Please call us or tell
us in your mail, so that we could regard your inquiry priority.