30 To 366 Nominal Tons Induced Draft Crossflow Closed Loop Cooling Tower

Model Number:GHM Series
Place of Origin:Jiangsu, China
Product Name:Induced Draft Crossflow Cooling Tower
Casing Material:special Mg-Al-Zn alloy coated steel or stainless steel
Capacity:30 to 366 nominal tons
Feature:high efficiency
Contact Now

Add to Cart

Verified Supplier
Location: Wuxi Jiangsu China
Address: Building A3, Tianan Smart City, Xinwu District, Wuxi City, Jiangsu Province
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

30 To 366 Nominal Tons Induced Draft Crossflow Cooling Tower Closed Loop Cooling Tower


Working Principle:


Induced draft cross-flow cooling towers use an induced draft fan, usually located at the top or side of the cooling tower, to draw air from the inside of the cooling tower.
This type of cooling tower is cross-flow, meaning that the cooling water flows relatively perpendicular to the air flow direction, which helps increase the heat exchange surface area and improve cooling efficiency.


Structural Features:


Induced draft cross-flow cooling towers usually have induced fans, fill layers and water collectors at the top or side.
Cooling water flows in from the top of the tower, passes through the fill layers, and exchanges heat with the rising air. The heat in the hot water is transferred to the air, thereby cooling the water temperature.


Advantages:


The design of the induced draft cross-flow cooling tower increases the contact area between the cooling water and the air, which helps improve the heat exchange efficiency.
The cross-flow design can reduce fill resistance, improve cooling effect, and reduce fan power consumption.


Application Fields:


Induced draft cross-flow cooling towers are widely used in various industrial fields, especially in power plants, chemical plants and other industrial processes that require a lot of cooling.
These cooling towers can help maintain normal operating temperatures for industrial equipment and reduce the heat generated during production processes.


Product Specification:


Model

No

Nominal

Flow Rate

(Ton)

FanCirculating PumpConnectig Pipe(mm)OverallDimensions(mm)Weight

Power

(kw)

Air volumn(m3/s)

Power

(kw)

Air volumn(m3/h)inlet/outlemake updrainageLWH

NET

(kg)

Running
(kg)
GHM-225301.1×23.7×21.545DN80DN25DN402540940220010201820
GHM-230371.1×23.7×21.545DN80DN25DN402960940220010502020
GHM-235431.1×23.7×21.545DN80DN25DN4029601940220011002100
GHM-340491.1×33.7×32.260DN80DN25DN4033601940220013102540
GHM-350611.1×33.7×32.260DN80×2DN25DN4033601940273014503080
GHM-365791.5×35.1×32.260DN80×2DN25DN4033601940273015203200
GHM-380981.5×45.1×42.2114DN80×2DN25DN4042202240268020504920
GHM-3901101.5×451x2.2114DN80×2DN25DN4042202240268021005000
GHM-31001221.5×45.1×42.2114DN80×2DN25DN4042202240284021505100
GHM-31101341.5×45.1×42.2114DN80×2DN25DN4042202240284022505250
GHM-51251521.5×45.1×43.7140DN100×2DN40DN4047402240291028006800
GHM-51501832.2×46.3×43.7140DN100×2DN40DN4054402240291032007820
GHM-51752132.2×46.3×43.7140DN125×2DN40DN4054402240291033008000
GHM-72002444x416.7×45.5160DN125×2DN40DMao58402900326050009000
GHM-72252744x416.7×45.5160DN125×2DN40DN4o584029003470550010000
GHM-72503054x416.7×45.5160DN150×2DN40DN40642029003470650011500
GHM-72753354×416.7×45.5160DN150×2DN40DN40642029003470680011800
GHM-73003664×416.7×45.5160DN150×2DN40DN40642029003470700012000

NOTE

Nominal Tons are based upon temp.drop 35~29.5℃/95~85°F,WBT 25.5℃/78°F,and 0.681 m³/hr/ton.



China 30 To 366 Nominal Tons Induced Draft Crossflow Closed Loop Cooling Tower supplier

30 To 366 Nominal Tons Induced Draft Crossflow Closed Loop Cooling Tower

Inquiry Cart 0