Fluke 1630-2 FC Earth Ground Clamp Fluke 1630 Ground Resistance Meter F1630-2 F1630

Brand Name:Fluke
Certification:CCCI
Model Number:Fluke 1630-2 FC Earth Ground Clamp Fluke 1630 Ground Resistance Meter F1630-2 F1630
Minimum Order Quantity:1
Delivery Time:7-10days
Payment Terms:Western Union, T/T
Contact Now

Add to Cart

Site Member
Location: Wuhu Anhui China
Address: No7 .Baizhuangkuajie zhanghe road, Yijiang zone, Wuhu City,Anhui Province,China 241000
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Specifications: Fluke 1630-2 FC Earth Ground Clamp

Electrical Specifications
Maximum voltage to earth ground1000 V
Battery typeAA alkaline IEC/EN LR6 (x4)
Battery lifeMore than 15 hours*
* In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off
Frequency range40 Hz to 1 kHz
Ingress protectionIEC/EN 60529: IP30 with jaw closed
LCDDigital reading9999 counts
Refresh rate4 per second
Operating temperature-10 °C to + 50 °C
Storage temperature-20 °C to + 60 °C
Operating humidityNon condensing (<10 °C) (< 50 °F)
≤90% RH (at 10 °C to 30 °C [50 °F to 86 °F])
≤75% RH (at 30 °C to 40 °C [86 °F to 104 °F])
≤45% RH (at 40 °C to 50 °C [104 °F to 122 °F])
(Non condensing)
Operating altitude2000 m (6561 feet)
Storage altitude12 000 m (39,370 feet)
Reference temperature23 °C ±5 °C (73 °F ±9 °F)
Temperature coefficient0.15% x (specified accuracy)/ °C (<18 °C or >28 °C [<64.4 °F or >82.4 °F])
Overload indicationOL
Data logging capacityMinimum of 32,760 measurements
Data logging interval1 second to 59 minutes and 59 seconds
Display reading specification with standard loop resistance
Input (Ω)MinimumMaximum
0.4740.4170.531
0.50.4430.558
109.5510.45
10096104
Safety
GeneralIEC/EN 61010-1: Pollution Degree 2 IEC/EN 61557-1
MeasurementIEC/EN 61010-2-032: CAT IV 600 V / CAT III 1000 V
Current clamp for leakage current measurementsIEC/EN 61557-13: Class 2, ≤30 A/m
Resistance to earthIEC/EN 61557-5
Effectiveness of thepProtective measuresIEC/EN 61557-16
Electromagnetic compatibility (EMC)InternationalIEC/EN 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class B, IEC/EN 61326-2-2
Korea (KCC)Class A equipment (Industrial Broadcast & Communications Equipment)
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Wireless Radio
Frequency range2412 MHz to 2462 MHz
Output power<10 mW
Radio frequency certificationFCC ID:T68-FBLE IC:6627A-FBLE
General Specifications
Conductor size40 mm (1.57 in) approximately
Dimensions (L x W x H)283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in)
Weight880g (31 oz)
WarrantyOne year
Earth Ground Loop Resistance
RangeAccuracy1 ± (% of reading + Ω)
0.025 Ω to 0.249 Ω1.5% + 0.02 Ω
0.250 Ω to 0.999 Ω1.5% + 0.05 Ω
1.000 Ω to 9.999 Ω1.5% + 0.10 Ω
10.00 Ω to 49.99 Ω1.5% + 0.30 Ω
50.00 Ω to 99.99 Ω1.5% + 0.50 Ω
100.0 Ω to 199.9 Ω3.0% + 1.0 Ω
200.0 Ω to 399.9 Ω5.0% + 5.0 Ω
400 Ω to 599 Ω10.0% + 10 Ω
600 Ω to 1500 Ω20.00%
1 Loop resistance with no inductance, conductor centered and perpendicular to jaw
Earth ground leakage current mA
Autorange 50/60 Hz, True rms, crest factor CF ≤3
RangeResolutionAccuracy1 ± (% of reading + mA)
0.200 mA to 3.999 mA1 μA2.0% + 0.05 mA
4.00 mA to 39.99 mA10 μA2.0% + 0.03 mA
40.0 mA to 399.9 mA100 μA2.0% + 0.3 mA
0.400 A to 3.999 A1 mA2.0% + 3 mA
4.00 A to 39.99 A10 mA2.0% + 30 mA

1 Applies to signal frequency

  • 40 Hz to 1 kHz with filter set to OFF
  • 40 Hz to 70 Hz with filter se t

China Fluke 1630-2 FC Earth Ground Clamp Fluke 1630 Ground Resistance Meter F1630-2 F1630 supplier

Fluke 1630-2 FC Earth Ground Clamp Fluke 1630 Ground Resistance Meter F1630-2 F1630

Inquiry Cart 0