Add to Cart
How to use (installation)
There are 12 steps required to install the sanitary metal tube
rotameter.
1. Clean the welding slag and debris in the pipeline before
installing the flow meter;
2. The installation inclination of the upright part of the
calibration flowmeter perpendicular to the ground shall not exceed
5°. Otherwise, the measurement accuracy will be affected.
3. Position In order to ensure the measurement accuracy of the flow
meter, a straight pipe section of no less than 10xDN should be
added to the inlet end of the flow meter, and a straight pipe
section of no less than 5xDN should be added to the outlet end. The
regulating control valve should be installed at the flow meter
during measurement. downstream.
4. Model If the measured medium is a large pulsating flow or
two-phase flow, a buffer should be installed upstream of the flow
meter to reduce or weaken the pulsation to ensure that the flow of
the medium is single-phase stable. At the same time, it is
recommended to use a damping type flow meter. .
5. Measuring medium When the measuring medium is dirty or contains
magnetically conductive particles, it is recommended to install a
filter or magnetic filter upstream of the flow meter.
6. The installation of the support flow meter should be able to
properly support the vibration of the pipeline or reduce the axial
load of the flow meter. Otherwise, the support of the fixed flow
meter should be added.
7. Maintenance In order to facilitate the maintenance and repair of
the flow meter, the cleaning of the magnetic filter and the regular
maintenance of the user's pipelines, it is recommended to use the
bypass pipeline as shown in the figure.
8. Stability When the flow meter is used for gas measurement, it
should be ensured that the working pressure in the pipeline is not
less than 5 times the pressure loss of the flow meter, so that the
flow meter can operate stably and normally.
9. Before using the electric remote transmission and the flow meter
with alarm limit switch, open the instrument cover and connect the
wires correctly according to the wiring diagram.
10. According to the warning plate on the indicator of the meter,
take out the damping piece that prevents the float from vibrating
during transportation, and then use the meter after restoring it.
11. If the flow meter is turned on, because there is no pressure in
the pipeline or the system has not reached the normal working
pressure of the instrument, slowly open the control valve until the
system is normal before the instrument can be used. Otherwise, it
is easy to cause the pointer to jump or the float to suddenly move.
A rose damaged by impact.
12. User use: When the user uses it, if the density of the measured
fluid is different from that of water, or the parameters and
working status of the measured gas are different from the
manufacturer's regulations, the flow meter indication reading
should be converted. The conversion method is shown in the
appendix.
Features
1. Strong all-metal structure design.
2. Suitable for gas and liquid measurement in various industries.
3. The new case structure design can be used in high temperature
environment without adding parts.
4. Specially designed cone measuring tube, wider measuring range,
better measuring linearity.
5. Can provide flange, clamp, thread and other process connection
methods, suitable for most factory application needs.
6. Measurement part of the material optional: stainless steel,
titanium, Hastelloy, PTFE, FEP and other materials.
7. The specially designed magnetic coupling system can
significantly improve the measurement accuracy and stability.
Specification
Measuring range | Water (20℃) 16~150000 l/h | LCD | Instantaneous flow rate display value range : 0.000~99999 |
Gas(0.1013MPa 20℃) 0.5~4000 m3/h | Cumulative flow display value range: 0.00~99999999 | ||
Jacket pressure rating | 1.6MPa | Electrical Interface | M20×1.5,PG11,1/2”NPT Or user provides specifications |
Medium temperature | Standard type -80℃~+220℃ | overall height | Standard type:250mm(For other installation methods, see the relevant table) |
High temperature type | 300℃ | Protection level | IP65/IP67 |
Lined FEP type | ≤85℃ | Explosion-proof signs | Intrinsically safe:ExiaIICT3~6 |
Explosionproof type:ExdIICT4~6 | |||
ambient temperature | -40℃~+120℃(C9≤85℃) (Remote transmission type with LCD display≤70℃) | Medium viscosity | DN15: ≤5mPa.s |
≤30mPa.s) | |||
DN25: ≤250mPa.s | |||
DN50~DN150:≤300mPa.s | |||
Range ratio | 10:1(Special type20:1) | output | Standard signal: two-wire system 4~20mA (can be equipped with HART communication) |
Standard signal: three-wire system 0~10mA | |||
Alarm signal: 1. Two relay outputs (limit value 125VAC/0.25A) | |||
2. One or two proximity switches (switch requirements are based on customer requirements) | |||
Pulse signal output: 0-1KHz isolated output (output level Vpp>4.5V) | |||
Accuracy level | 2.5(Special type1.5%or 1.0%) | powered by | Standard type: 24VDC±20% |
AC type: 220VAC (85~265VAC) (need to be customized) | |||
Battery type: 3.7@4.4-5.2AH lithium battery. According to different usage conditions, each group can be used (3 to 12 months), and the two groups can be used interchangeably. | |||
work pressure | DN15~DN50 PN16MPa (Special type 25MPa) | Connection method | Standard type: HG20592 flange |
DN80~DN150 PN10MPa (Special type 16MPa) | Special type: user provides flange standard | ||
Threaded connection type: user specified |
Precautions
Precautions when using the sanitary metal tube rotor flowmeter.
1. Metal rotor flowmeter, metal tube float flowmeter, and Verabar
flowmeter with high temperature resistance up to 450°C.
2. Suitable for measuring small diameter and low flow rate gas,
liquid and steam flow.
3. High-voltage resistant magnetic coupling principle, no leakage
and high pressure resistance.
4. Measure the flow rate. When the flow rate exceeds 100m3/h water
flow rate, the pressure loss will be large. .
5. The measuring range is mostly used for process control
instruments, with an accuracy of 1%, usually 1.5%, and a range
ratio of 10:1.
6. Suitable for occasions, including intrinsically safe
explosion-proof and explosion-proof types, suitable for dangerous
occasions.
7. Installation method The appropriate installation method is
vertical installation with bottom in and top out.
Manufacturer strength
Smart instrument direct supply manufacturer
The company has complete production and processing equipment. The
electronics workshop has a modern SMT assembly line and a complete
electronic design and development laboratory. The machinery
workshop has multiple precision CNC lathes, ordinary lathes,
processing, fully automatic circumferential seam welding machines,
drilling machines and other equipment. The calibration workshop has
two liquid calibration test lines and a small and medium flow gas
calibration test line to ensure that each product is tested
according to actual conditions. Calibration and verification to
ensure product quality.
Standard dimensions and weight
Jacket type overall dimensions and weight
Lined FEP type overall dimensions and weight
Dimensions and weight of top-in and bottom-out type
Side-in and side-out type: overall dimensions, weight and pressure loss
Bottom entry and side exit type: overall dimensions, weight and pressure loss
Horizontal installation type: overall dimensions, weight and pressure loss
FAQ
1. Q: What information need to be provided to choose the suitable
model?
A: Application field, Nominal pressure ,Medium & medium
temperture , Power supply , Output,
Flow range, Accuracy, Connection and other parameters.
2. Q: Are you a trade company or a manufacturer?
A: We are an ISO approved manufacturer specialized in level and
flow measuring instruments.
OEM & ODM service are available. Welcome to visit us in China.
3. Q: What is your MOQ?
A: To start our cooperation, sample order is acceptable.
4. Q: What is your delivery date for the Intelligent Mini Micro
Turbine Fuel Oil Diesel Flow Meter?
A: The delivery date is about 3-15 working days after receipt of
payment.
5. Q: What is your payment terms?
A: We support T/T, PayPal ,Western Union.
For mass production order, it is 30% deposit in advance and 70%
balance before shipment.
6. Q: Do you have a warranty for the Flow Meter?
A: Yes, we have the warranty of 12 months.