Concentrated sulfuric acid flow meter PTFE lined battery operated electromagnetic flow meter

Brand Name:BEITE
Certification:CE ISO
Minimum Order Quantity:1 Piece/Pieces
Delivery Time:5 working days after payment
Payment Terms:T/T, Western Union
Place of Origin:CHINA
Contact Now

Add to Cart

Verified Supplier
Location: Suzhou Jiangsu China
Address: No. 66, Changwang Road, Dongqiao Town, Xiangcheng District, Suzhou City, Jiangsu Province
Supplier`s last login times: within 34 hours
Product Details Company Profile
Product Details

Characteristics of electromagnetic flowmeter
The working principle of the electromagnetic flowmeter is based on the law of electromagnetic induction. It is a flow meter with classic measurement principles, mature technology, good temporary stability, and low maintenance. It is also used in water diversion projects, water plants, and sewage treatment plants. The most commonly used flow meter is the inlet and outlet water flow measurement. Electromagnetic flowmeter has the following characteristics:

1. No moving parts, high reliability, good long-term stability and low maintenance;

2. No additional resistance. This is particularly important for large-diameter flowmeters;

3. High measurement accuracy. Typical product accuracy can reach ±0.5%R

4. Large measuring range. The range of guaranteed accuracy can generally reach 40:1v=0.08m/hour, and the basic error can still be less than ±2%R

5. The requirements for straight pipe sections are relatively low. This is also important when it comes to large diameter pipes. There are many kinds of flow meters that require the front and rear straight pipe sections to reach 5D3D

6. Large-diameter electromagnetic flowmeter and ultrasonic flowmeter products are available for design and selection. The largest electromagnetic flowmeter in China provides DN3200 products. Ultrasonic flowmeters can reach larger diameters, thereby meeting the needs for large diameter and large flow water flow measurement;

7. Complete range. There are integrated IP65 and split submersible IP68 products;

8. The disadvantage is that the conductivity of the fluid being measured must be greater than 5μs and the price of the instrument increases as the diameter increases.


Features
1. Measurement is not affected by the variation of flow density, viscosity, temperature, pressure and conductivity. High accuracy measurement is guaranteed according to the linear measurement principle.
2. No obstacle in the pipe, no pressure-loss and lower requirement for straight pipeline.
3. DN 6 to DN2000 covers a wide range of pipe size. A variety of liners and electrodes are available to satisfy different flow characteristic.
4. Programmable low frequency square wave field excitation, improving measurement stability and reducing power consumption.
5. Implementing 16 bits MCU, providing high integration and accuracy; Full-digital processing, high noise resistance and reliable measurement; Flow measurement range up to 1500:1.
6. High definition LCD display with backlight.
7. RS485 or RS232 interface supports digital communication.
8. Intelligent empty pipe detection and electrodes resistance measurement diagnosing empty pipe and electrodes contamination accurately.
9. SMD component and surface mount technology (SMT) are implemented to improve the reliability.

Main Applications

TQMF electromagnetic flowmeter can be used to measure the volume flow of conductive fluid in a closed pipeline. It is widely applied in the flow measurement and control in the fields of chemical and petroleum industry, metallurgy industry, water and waste water, agriculture and irrigation, paper making, food and beverage industry and pharmaceutical industry. 1.3Ambient Conditions Ambient temperature: sensor: -25℃ to + 60℃; converter: -25℃ to + 60℃. Relative humidity: 5% to 90%; 1.4Working Conditions Maximum fluid temperature: Compact type: 60℃ Remote type: Teflon 150℃ Neoprene 80℃; 120℃ Polyurethane 70℃ Fluid conductivity: ≥ 5S/cm


Measuring Principles

The measuring principle of electromagnetic flowmeter is based on the electromagnetic induction law of Farady. The sensor is mainly composed of measuring tube with isolate lining, a pair of electrodes installed by penetration of the measuring tube wall, a pair of coils and iron core to produce working magnetic field. When the conductive fluid flows through the measuring tube of the sensor, the voltage signal in direct proportion to the average flow velocity of the fluid will be inducted on the electrodes. The signal is amplified and treated by the transmitter to realize various display functions.

Converter Circuit Schematic

The converters supplies a stable exciting current to the coil in the sensor of electronetic flowmeters to get B constant and amplifies the electromotive force and convert it into standard signals of current or frequency so that the signals can be used for displaying, controlling and processing. The schematic of converter circuit is shown in Fig. 2.1.


Table of Parameter Setting Menu

The converter setting menu consists of 45 items. Many of them are set up by manufacturer before shipping. It is not necessary to change them when applying. There are only a few of them to be set by user according to the application. The menu items are listed in the table below:

Item No.Menu DisplaySetting MethodPassword LevelValue Range
1LanguageOption1Chinese/English
2Sensor SizeOption13 - 3000mm
3Flow RangeModify10 - 99999
4Auto Rng ChgOption1ON / OFF
5DampingOption10 - 100 s
6Flow Dir.Option1Fwd/ Res
7Flow ZeroModify1+/-0.000
8L.F. CutoffModify10 - 99%
9Cutoff EnbleOption1ON / OFF
10Rate-Of-ChngModify10 - 30%
11Limit TimeModify10 - 20 s
12Total UnitOption10.0001L - 1 m3
13Flow DensityModify10.0000 - 3.9999
14Current TypeOption14-20mA/0-10mA
15Pulse OutputOption1Frq/ Pulse
16Pulse FactorOption10.001L - 1 m3
17Freq MaxModify11 - 5999 Hz
18Comm AddressModify10 - 99
19BaudrateOption1600 - 14400
20EmpPipe Det.Option1ON / OFF
21EmpPipe AlmModify1200.0 KΩ
22Hi ALM EnbleOption1ON / OFF
23Hi Alm LimitModify1000.0 - 199.9%
24Lo Alm EnbleOption1ON / OFF
25Lo Alm LimitModify1000.0 - 199.9%
26RevMeas.EnblOption1ON/OFF
27Sensor S/NModify2000000000000-999999999999
28Sensor Fact.Modify20.0000 - 3.9999
29Field ModeOption2Mode 1,2,3
30MultiplyingModify20.0000 - 3.9999
31F. Total SetModify30000000000 - 9999999999
32R.Total SetModify30000000000 - 9999999999
33Input ContrlOption3Disable/Stop Tot/Reset Tot
34Clr TotalizrPassword300000 - 59999
35Clr Tot. KeyModify300000 - 59999
36Date –y/m/d *Modify399/12/31
37Time-h/m/s *Modify323/59/59
38Password L1Modify30000 - 9999
39Password L2Modify30000 - 9999
40Password L3Modify30000 - 9999
41Current ZeroModify40.0000 - 1.9999
42Current MaxModify40.0000 - 3.9999
43Meter FactorModify40.0000 - 3.9999
44Convtr S/NModify40000000000-9999999999
45Sys ResetPassword4

Scenario application:


FAQ
1. Q: What information need to be provided to choose the suitable model?
A: Application field, Nominal pressure ,Medium & medium temperture , Power supply , Output,
Flow range, Accuracy, Connection and other parameters.
2. Q: Are you a trade company or a manufacturer?
A: We are an ISO approved manufacturer specialized in level and flow measuring instruments.
OEM & ODM service are available. Welcome to visit us in China.
3. Q: What is your MOQ?
A: To start our cooperation, sample order is acceptable.
4. Q: What is your delivery date for the Intelligent Mini Micro Turbine Fuel Oil Diesel Flow Meter?
A: The delivery date is about 3-15 working days after receipt of payment.
5. Q: What is your payment terms?
A: We support T/T, PayPal ,Western Union.
For mass production order, it is 30% deposit in advance and 70% balance before shipment.
6. Q: Do you have a warranty for the Flow Meter?
A: Yes, we have the warranty of 12 months.

China Concentrated sulfuric acid flow meter PTFE lined battery operated electromagnetic flow meter supplier

Concentrated sulfuric acid flow meter PTFE lined battery operated electromagnetic flow meter

Inquiry Cart 0