Flange Type Electromagnetic Flowmeter accuracy high

Brand Name:BEITE
Certification:CE ISO
Minimum Order Quantity:1 Piece/Pieces
Delivery Time:5 working days after payment
Payment Terms:T/T, Western Union
Place of Origin:CHINA
Contact Now

Add to Cart

Verified Supplier
Location: Suzhou Jiangsu China
Address: No. 66, Changwang Road, Dongqiao Town, Xiangcheng District, Suzhou City, Jiangsu Province
Supplier`s last login times: within 34 hours
Product Details Company Profile
Product Details

working principle

According to Faraday's electromagnetic induction principle, a pair of detection electrodes are installed on the tube wall perpendicular to the axis of the measuring tube and the magnetic field lines. When the conductive liquid moves along the axis of the measuring tube, the conductive liquid cuts the magnetic field lines to generate an induced electric potential. This induced electric potential is composed of two The detection electrode detects that the numerical value is proportional to the flow rate, and its value is:
E=KBVD

In the formula:
E - induced electric potential;
K - coefficient related to magnetic field distribution and axial length;
B - magnetic induction intensity;
V - average flow velocity of conductive liquid;
D - electrode distance; (measuring tube inner diameter)


Electromagnetic flowmeter installation requirements
1. For horizontal and vertical flow directions, the electromagnetic flowmeter should be installed at the lower part of the horizontal pipe and the vertical upward part, and avoid installing it at the highest point and vertical downward part of the pipe;

2. When the flow direction is inclined, the electromagnetic flowmeter should be installed at the rising point of the pipe;

3. When opening the discharge pipe, the electromagnetic flowmeter should be installed at the lower part of the pipe;

4. When the pipeline drop exceeds 5 meters, an exhaust valve should be installed downstream of the electromagnetic flowmeter;

5. The control valve and cut-off valve on the pipeline should be installed downstream of the electromagnetic flowmeter and should not be installed upstream of the sensor;

6. The electromagnetic flowmeter cannot be installed at the inlet of the pump, but should be installed at the outlet;

7. How to install electromagnetic flowmeter in the measuring well;


Features
1. Measurement is not affected by the variation of flow density, viscosity, temperature, pressure and conductivity. High accuracy measurement is guaranteed according to the linear measurement principle.
2. No obstacle in the pipe, no pressure-loss and lower requirement for straight pipeline.
3. DN 6 to DN2000 covers a wide range of pipe size. A variety of liners and electrodes are available to satisfy different flow characteristic.
4. Programmable low frequency square wave field excitation, improving measurement stability and reducing power consumption.
5. Implementing 16 bits MCU, providing high integration and accuracy; Full-digital processing, high noise resistance and reliable measurement; Flow measurement range up to 1500:1.
6. High definition LCD display with backlight.
7. RS485 or RS232 interface supports digital communication.
8. Intelligent empty pipe detection and electrodes resistance measurement diagnosing empty pipe and electrodes contamination accurately.
9. SMD component and surface mount technology (SMT) are implemented to improve the reliability.


Main Applications

TQMF electromagnetic flowmeter can be used to measure the volume flow of conductive fluid in a closed pipeline. It is widely applied in the flow measurement and control in the fields of chemical and petroleum industry, metallurgy industry, water and waste water, agriculture and irrigation, paper making, food and beverage industry and pharmaceutical industry. 1.3Ambient Conditions Ambient temperature: sensor: -25℃ to + 60℃; converter: -25℃ to + 60℃. Relative humidity: 5% to 90%; 1.4Working Conditions Maximum fluid temperature: Compact type: 60℃ Remote type: Teflon 150℃ Neoprene 80℃; 120℃ Polyurethane 70℃ Fluid conductivity: ≥ 5S/cm


L.F. Cutoff and Cutoff Enble
Low flow cutoff is set in percentage relative to flow range. If Cutoff is enabled and flow is lower than the set value, the display of flow rate, speed and percentage and signal outputs are forced to nil. If the item is disabled, no action is taken.


Measuring Principles

The measuring principle of electromagnetic flowmeter is based on the electromagnetic induction law of Farady. The sensor is mainly composed of measuring tube with isolate lining, a pair of electrodes installed by penetration of the measuring tube wall, a pair of coils and iron core to produce working magnetic field. When the conductive fluid flows through the measuring tube of the sensor, the voltage signal in direct proportion to the average flow velocity of the fluid will be inducted on the electrodes. The signal is amplified and treated by the transmitter to realize various display functions.

Converter Circuit Schematic

The converters supplies a stable exciting current to the coil in the sensor of electronetic flowmeters to get B constant and amplifies the electromotive force and convert it into standard signals of current or frequency so that the signals can be used for displaying, controlling and processing. The schematic of converter circuit is shown in Fig. 2.1.


Table of Parameter Setting Menu

The converter setting menu consists of 45 items. Many of them are set up by manufacturer before shipping. It is not necessary to change them when applying. There are only a few of them to be set by user according to the application. The menu items are listed in the table below:

Item No.Menu DisplaySetting MethodPassword LevelValue Range
1LanguageOption1Chinese/English
2Sensor SizeOption13 - 3000mm
3Flow RangeModify10 - 99999
4Auto Rng ChgOption1ON / OFF
5DampingOption10 - 100 s
6Flow Dir.Option1Fwd/ Res
7Flow ZeroModify1+/-0.000
8L.F. CutoffModify10 - 99%
9Cutoff EnbleOption1ON / OFF
10Rate-Of-ChngModify10 - 30%
11Limit TimeModify10 - 20 s
12Total UnitOption10.0001L - 1 m3
13Flow DensityModify10.0000 - 3.9999
14Current TypeOption14-20mA/0-10mA
15Pulse OutputOption1Frq/ Pulse
16Pulse FactorOption10.001L - 1 m3
17Freq MaxModify11 - 5999 Hz
18Comm AddressModify10 - 99
19BaudrateOption1600 - 14400
20EmpPipe Det.Option1ON / OFF
21EmpPipe AlmModify1200.0 KΩ
22Hi ALM EnbleOption1ON / OFF
23Hi Alm LimitModify1000.0 - 199.9%
24Lo Alm EnbleOption1ON / OFF
25Lo Alm LimitModify1000.0 - 199.9%
26RevMeas.EnblOption1ON/OFF
27Sensor S/NModify2000000000000-999999999999
28Sensor Fact.Modify20.0000 - 3.9999
29Field ModeOption2Mode 1,2,3
30MultiplyingModify20.0000 - 3.9999
31F. Total SetModify30000000000 - 9999999999
32R.Total SetModify30000000000 - 9999999999
33Input ContrlOption3Disable/Stop Tot/Reset Tot
34Clr TotalizrPassword300000 - 59999
35Clr Tot. KeyModify300000 - 59999
36Date –y/m/d *Modify399/12/31
37Time-h/m/s *Modify323/59/59
38Password L1Modify30000 - 9999
39Password L2Modify30000 - 9999
40Password L3Modify30000 - 9999
41Current ZeroModify40.0000 - 1.9999
42Current MaxModify40.0000 - 3.9999
43Meter FactorModify40.0000 - 3.9999
44Convtr S/NModify40000000000-9999999999
45Sys ResetPassword4

Scenario application:


FAQ
1. Q: What information need to be provided to choose the suitable model?
A: Application field, Nominal pressure ,Medium & medium temperture , Power supply , Output,
Flow range, Accuracy, Connection and other parameters.
2. Q: Are you a trade company or a manufacturer?
A: We are an ISO approved manufacturer specialized in level and flow measuring instruments.
OEM & ODM service are available. Welcome to visit us in China.
3. Q: What is your MOQ?
A: To start our cooperation, sample order is acceptable.
4. Q: What is your delivery date for the Intelligent Mini Micro Turbine Fuel Oil Diesel Flow Meter?
A: The delivery date is about 3-15 working days after receipt of payment.
5. Q: What is your payment terms?
A: We support T/T, PayPal ,Western Union.
For mass production order, it is 30% deposit in advance and 70% balance before shipment.
6. Q: Do you have a warranty for the Flow Meter?
A: Yes, we have the warranty of 12 months.

China Flange Type Electromagnetic Flowmeter accuracy high supplier

Flange Type Electromagnetic Flowmeter accuracy high

Inquiry Cart 0