Add to Cart
Warning and Caution
Description
For pressure/differential pressure transmitters, there are two
mounting brackets available, and the installation method is the
typical installation method. Secure the pressure transmitter to the
mounting bracket with the 4 bolts provided. Then fix the
pipe-mounted bracket (B1) and the transmitter on a horizontal or
vertical pipe of about φ50mm through U-shaped bolts or fix the
panel-mounted bracket (B2) on the instrument panel with M10 bolts
(prepared by the user). To facilitate the connection of the flange
or transition joint with the pressure piping, the direction of the
transmitter can be rotated. If the flange remains vertical after
rotation, there will be no change in the zero point. If the flange
is turned to a horizontal position, the resulting change in zero
point is equal to the liquid level difference caused by the change
in position.
Check whether the power supply of the differential pressure
transmitter is connected reversely and whether the positive and
negative poles of the power supply are connected correctly. Measure
the power supply of the transmitter to see if there is 24V DC
voltage; it must be ensured that the power supply voltage supplied
to the transmitter is ≥12V (that is, the voltage at the input
terminal of the transmitter power supply is ≥12V). If there is no
power supply, check whether the circuit is disconnected, whether
the detection instrument is selected incorrectly (input impedance
should be ≤250Ω), etc. If the pressure transmitter is equipped with
a meter head, you need to check whether the meter head is damaged
(you can short-circuit the two wires of the meter head first. If
the short circuit is normal, it means the meter head is damaged).
If the meter head is damaged, you need to Replace the header. If
there is a problem with the differential pressure transmitter, you
can connect an ammeter in series to the 24V power supply circuit to
check whether the current is normal. If it is normal, it means the
transmitter is normal. At this time, you should check whether other
instruments in the loop are normal. Check whether the power supply
is connected to the power input end of the transmitter, and connect
the power cord to the power connection port.
Specification
● Wide measuring range: 0-0.2kpa~41.37Mpa;
● The accuracy is better than 0.075 level, and the range ratio is
better than 100:1;
● It truly realizes electrical isolation, reduces the impact of
grounding, and improves anti-interference performance.
● Enhanced anti-interference design, strong on-site
anti-interference ability.
● The core circuit of the smart transmitter is all built-in sensors
and encapsulated as a whole, making the transmitter highly
reliable.
● Minimal temperature drift: When performing temperature
compensation on the transmitter, the circuit board and sensor
perform unified temperature compensation in the same temperature
field, so the compensation effect is better and the temperature
drift is further reduced;
● Zero point and span adjustment do not affect each other;
● Powerful on-site configuration functions: zero point, full scale,
display, unit, upper and lower range limits, damping, etc. are
adjustable.
● High-brightness backlit LCD display for easy reading in dark
environments. The display head can be rotated 360° to facilitate
on-site observation;
● The sensor has non-volatile memory;
● Good stability, high precision, adjustable damping, and strong
one-way overload resistance;
● Two-wire system, compliant with HART® protocol.
● No mechanical transmission parts, less maintenance work, strong
and vibration-resistant;
● The diaphragm material contacting the medium is optional, and the
explosion-proof shell is optional;
Pressure Range | |
Nominal Range | -100kPa, 35kPa, 70kPa, 100kPa, 160kPa, 250kPa, 400kPa, 600kPa,
1MPa, 1.6MPa, 2.5MPa, 4MPa, 6MPa, 10MPa, 16MPa, 25MPa, 40MPa, 60MPa, 100MPa |
Pressure Reference | Gauge pressure | Absolute pressure | Sealed gauge pressure |
Overpressure | 300%F.S.(≤70kPa) | 200%F.S.(<25MPa) | 150%F.S(≥25MPa) |
Output Signal | |
Output | 4 to 20mA + Hart protocol | 4 to 20mA + RS485-MODBUS |
Specification | |
Accuracy (linearity, hysteresis and repeatability) | ±0.5%F.S.(typical) |
Supply | 24VDC(typical) |
Compensated Temp. | -10ºC - 70ºC(typical) |
Medium Temp. | -30ºC - 100ºC |
Ambient Temp. | -40ºC - 85ºC |
Storage Temp. | -40ºC - 125ºC |
Zero Temp. Coefficient | ±1.5%F.S.max.(@-20ºC - 85ºC) |
Sensitivity Temp. Coefficient | ±1.5%F.S.max.(@-20ºC - 85ºC) |
Housing material | Copper aluminum alloy |
Sensor material | Stainless steel 316L |
Protection | IP65 |
Weight | Approx.(1500g) |
Packing & Delivery
FAQ
1. Q: What information need to be provided to choose the suitable
model?
A: Application field, Nominal pressure ,Medium & medium
temperture , Power supply , Output,
Flow range, Accuracy, Connection and other parameters.
2. Q: Are you a trade company or a manufacturer?
A: We are an ISO approved manufacturer specialized in level and
flow measuring instruments.
OEM & ODM service are available. Welcome to visit us in China.
3. Q: What is your MOQ?
A: To start our cooperation, sample order is acceptable.
4. Q: What is your delivery date for the Intelligent Mini Micro
Turbine Fuel Oil Diesel Flow Meter?
A: The delivery date is about 3-15 working days after receipt of
payment.
5. Q: What is your payment terms?
A: We support T/T, PayPal ,Western Union.
For mass production order, it is 30% deposit in advance and 70%
balance before shipment.
6. Q: Do you have a warranty for the Flow Meter?
A: Yes, we have the warranty of 12 months.