Features of ultrasonic level meter
Displays liquid level, distance, echo waveform, and historical
curve.
Automatically detects on-site electrical interference and
suppresses interference.
Internally integrated temperature sensor to perform temperature
compensation for sound velocity in real time.
Provides alarm current output to prevent the liquid level from
entering the blind area or exceeding the range.
Comes with 4-20mA current simulation, liquid level simulation,
RS485 communication test and other functions.
Built-in buttons can be used to set parameters on site; remote
parameter setting can also be performed via RS485.
Chinese and English display can be selected; meters and feet can
also be selected; HART interface is optional;
All input and output lines have overvoltage and overcurrent
protection.
Non-contact measurement, long life.
Description
Ultrasonic liquid level gauge is a digital liquid level instrument controlled by a microprocessor. In the measurement, the ultrasonic pulse is emitted by the sensor (transducer). The sound wave is reflected by the liquid surface and is received by the same sensor or ultrasonic receiver. It is converted into an electrical signal through a piezoelectric crystal or magnetostrictive device, and is transmitted and received by the sound wave. time to calculate the distance from the sensor to the surface of the liquid being measured. Due to the non-contact measurement, the measured medium is almost unlimited and can be widely used to measure the height of various liquid and solid materials.
Multi-pulse low-voltage multi-point transmitting circuit,
double-balanced noise suppression multi-point receiving circuit
It improves the reliability of the instrument, solves the problem
of inaccurate measurement of uneven material levels, and greatly
enhances the anti-interference ability, allowing it to work stably
near the transmission tower of the substation.
Automatic power adjustment, gain control, temperature compensation.
Yingling's detection technology and rich software functions are
suitable for various complex environments.
Waveform calculation technology improves the measurement accuracy
of the instrument.
The interference echo suppression function ensures the authenticity
of the measurement data.
16-bit D/A conversion improves the accuracy and resolution of
current output.
The sensor is made of tetrafluoroethylene material and can be used
in various corrosive situations.
Multiple output forms: programmable relay output, high-precision
4-20mA current output, Rs-485 digital communication output, split
ultrasonic liquid level probe.
Specification
Main parameters of integrated ultrasonic liquid level meter
Measuring range | 0-3, 5, 8, 10, 15, 20, 30, 40, 50 100m |
Accuracy | 0.25% |
blind spot | 0.15-0.7m |
Operating temperature | -20℃-+60℃ |
pressure range | -1-16kg |
power supply | 24VDC, 220VAC |
output | 4-20mA, Rs-485 |
control | Two-way relay |
Protection level | IP68 |
Display method | 12864 dot LCD display |
Main parameters of corrosion-resistant sensor housing type split-type ultrasonic liquid level meter
Measuring range | 0-3, 5, 8, 10, 15, 20m, 30, 40, 50, 60, 70m |
Accuracy | 0.25% |
blind spot | 0.15-1.2m |
Operating temperature | Transmitter-20℃-55℃ Sensor-25℃-80℃ |
pressure range | -1-16kg |
power supply | 24VDC, 220VAC |
output | 4-20mA, Rs-485 |
control | Four way relay |
Protection level | IP68 |
Display method | 12864-dot LCD display, corrosion-resistant sensor housing made of tetrafluoroethylene |
Technical indicators
Measuring range | 0.3~5m, 0.3~8m, 0.5~12m |
blind spot | <0.3m,<0.5 m |
launch angle | 12° Small display resolution: 1mm |
Accuracy | ±0.3%×range |
show | Four digits and eight segments: 0.5-inch LED |
working frequency | 20 KHz ~ 43.0KHz (varies depending on model specifications) |
Site settings | Calibration is completed through the level meter button: factory calibration, can be calibrated on site |
Analog output signal | 4~20mA load>300Ω; 0~5V; 1~5V |
digital output | RS485 (supports Modbus) NPN switch output |
Operating Voltage | DC12—24V power consumption<1.5W |
Dimensions | Φ83×145×M65 |
shell material | PP |
weight | 272g(5m); 410g(12m) |
Installation method | External straight pipe thread M65×1.5 |
Protection level | IP65 |
temperature | -10℃~60℃ |
Installation principle
When the ultrasonic liquid level meter is working, high-frequency
pulse sound waves are emitted by the transducer (probe) and are
reflected by the surface of the measured object (water surface).
The refracted reflected echo is received by the same transducer
(probe) and converted into an electrical signal. . The time between
pulse transmission and reception (the movement time of the sound
wave) is proportional to the distance from the transducer to the
object surface. The relationship between the sound wave
transmission distance S, the sound speed C and the transmission
time T can be expressed by the formula: S= CⅩT /2
When installing an ultrasonic liquid level meter, the blind zone
problem of the ultrasonic liquid level meter must be considered.
When the liquid level enters the blind zone, the ultrasonic
transmitter cannot measure the liquid level. Therefore, when
determining the measuring range of the ultrasonic liquid level
meter, a margin of 50 cm must be left. When installing, the
transmitter probe must be higher than the maximum liquid level. The
position is about 50 centimeters. Only in this way can the accurate
monitoring of the liquid level and the safety of the ultrasonic
liquid level meter be ensured.
In actual use, due to poor installation considerations, the liquid
level gauge was submerged in water, causing the liquid level gauge
to be completely damaged.
Features of SGM ultrasonic level meter
Low price, small size and light weight, it can be used for
non-contact level measurement of liquids and bulk solids in food,
chemical, semiconductor and other industries, and can be used for
remote level monitoring and pump control.
Attention should be paid to mechanical installation: the
installation should be perpendicular to the surface of the object
to be measured, avoid being used to measure foam objects, and avoid
being installed at a distance less than the blind zone distance
from the surface of the measured object (blind zone: each product
will have a standard, which will be known with the product) , it
should be considered that the beam avoids blocking materials and
does not meet the filling mouth and container wall. When detecting
large solid objects, the probe orientation should be adjusted to
reduce measurement errors.
Catalog
BTSL7100 | Ultrasonic level gauge | |||
model | A | One-piece two-wire system | ||
B | Integrated three-wire system | |||
C | Integrated four-wire system | |||
D | Split four-wire streamlined type | |||
E | Split four-wire standard type | |||
Range ratio | 4 | L=4m | ||
6 | L=6m | |||
8 | L=8m | |||
10 | L=10m | |||
12 | L=12m | |||
15 | L=15m | |||
20 | L=20m | |||
30 | L=30m | |||
40 | L=40m | |||
custom | L=…..m | |||
voltage | D | DC24V LCD liquid crystal display | ||
E | DC24V LED digital tube display | |||
A | AC220V LCD liquid crystal display | |||
Probe extension | **mm |
Packing & Delivery
FAQ
1. Q: What information need to be provided to choose the suitable
model?
A: Application field, Nominal pressure ,Medium & medium
temperture , Power supply , Output,
Flow range, Accuracy, Connection and other parameters.
2. Q: Are you a trade company or a manufacturer?
A: We are an ISO approved manufacturer specialized in level and
flow measuring instruments.
OEM & ODM service are available. Welcome to visit us in China.
3. Q: What is your MOQ?
A: To start our cooperation, sample order is acceptable.
4. Q: What is your delivery date for the Intelligent Mini Micro
Turbine Fuel Oil Diesel Flow Meter?
A: The delivery date is about 3-15 working days after receipt of
payment.
5. Q: What is your payment terms?
A: We support T/T, PayPal ,Western Union.
For mass production order, it is 30% deposit in advance and 70%
balance before shipment.
6. Q: Do you have a warranty for the Flow Meter?
A: Yes, we have the warranty of 12 months.