Terminal Connection Yc1891d-6 Single Phase Meter Test System for Accurate Measurements

Specifications:

Application Conditions and Requirement
EnvironmentPower RequirementSafety
OperationHumidityAltitudeVoltage SupplyIP ClassConformity
Temperature
-10°C--+40°C35%--85%< 2500m3x220/380v±10%(or customized)IP 30CE conformity
50/60Hz±2Hz
TypeYC1891D-6YC1891D-12YC1891D-24YC1891D-48
Number of meter positions6122448
Accuracy0.05
Power SourceYC8-101-250YCS-101-600YCS-101-1200YCS-101-2500
Standard MeterSZ-01A-K3
MSTVHJ200G-6HJ200G-12HJ200G-24HJ200G- 48
Scanning HeadYCG-2-series
Voltage
Test voltage output (Phase-Neutral)24V-300V(or customized)
Power of the voltage outputMax.100VAMax.250VAMax.500VAMax.1000VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h(integration time 150 s)
Load regulation from O-max.loadBetter than 0.01%
Distortion factorBetter than 0.3% for linear resistance load
Harmonics2nd - 41st free programmable
Current
Test current output1mA-120A/200A
Power of the current outputMax.250VA Max.500VA Max.1000VA Max.2000VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h(integration time 150 s)
Load regulation from O-max.loadBetter than 0.01%
Distortion factorBetter than 0.3% for linear resistance load
Harmonics2nd - 41st free programmable
Phase angle
Phase angle0°-360°
Resolution0.01°
Setting accuracy0.1°
Frequency
Range45Hz-65Hz
Resolution0.01Hz
Error display
Type of error displayRed LED
Resolution of the error displays8 digits

Description:

1. The meter test system can measure mechanical meter, electronic mechanical meters and electronic meter by ways of automatic, semi-automatic or manual operation.

2. Meters under testing: 1P2W

3. Testing mode: active power, reactive power, cross connected reactive power

4. With MSVT, can test single-phase meters with closed links between the current and voltage measuring circuits (I-P links)

5. With current output switch, can calibrate 2 element meter(optional)

6. Simultaneously measure meters with same specifications but different meter constants

7. Automatic positioning rotor mark of disc of mechanical meter, with more efficiency.

8. Starting test and creeping test

9. With the protection function of overload, short voltage circuit and open current circuit.

10. The swing together of the scanning heads simplifies the control.

11. Aluminum alloy material, light and strong and corrosion resistant

12. The testing software with friendly Windows 2000 /XP /7 /8 /10 operation system, includes functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test etc,.

Applications:

1. Nation-level utility companies

2. Governmental bureaus of metrology

3. Big energy meter manufacturers

Primary Competitive Advantages:

1. High quality product

2. Over 18 months long warranty

3. High accuracy class: 0.05

4. 3~48 Single Phase Electric Energy Meter Test bench

5. Extremely high power stability

6. Neutral current test(optional)

7. Timing error test

8. Influence test of voltage, frequency, and harmonic

9. Installing RS232, Ethernet communication port in each meter position.

10. Tilt impact test (optional)