Add to Cart
Can test one meter or two meters at the same time.
Automatic test sequence using the scanning head for electronic and electromechanical meters
Can synchronously calculate all data and display on the interface include full wave
Can test active and reactive energy accuracy of full wave meter
Can simultaneously test two channel pulses whose pulse constant
Wiring identification is available when no load.
Electric energy accumulation function can measure the electric energy meter when it has not pulse output.
Dial test function
Display vector diagram
Can identify wrong wiring (48 types connections)
Instrument can be simulate the scene of variety of wiring and get corresponding the result of wiring and revised parameter in office without access to voltage or current signal situation
Harmonic functions
Test Voltage (Full Wave & Fundamental Wave) | |
Range | 0~500V |
Error | ±0.05% (0.1%) |
Harmonic | 2nd ~ 51st |
Test Current (Full Wave & Fundamental Wave) | |
Range (direct connection) | 0.025A ~ 12A (Ie=5A) |
Range (100AClamp CT) | 0.5~120A (Ie=100A,usage range=0.01Ie~2.4Ie) (Optional: Ie=5A, 500A, 1000A) |
Error (direct connection) | ±0.05% (0.1%) |
Error (100AClamp CT) | ±0.2%(5A,100A) ±0.5% (other) |
Harmonic | 2nd ~ 51st |
Starting current | 0.05%Ie |
Power Measure Error (Full Wave & Fundamental Wave) | |
Active Power (Direct connection) | ±0.05% |
Active Power (100A ClampCT) | ±0.2%(5A,100A) ±0.5% (other) |
Reactive Power (Direct connection) | ±0.1% |
Reactive Power (100A ClampCT) | ±0.5%(5A,100A) ±1.0% (other) |
Energy Measure Error (Full Wave & Fundamental Wave) | |||
Active Energy (Direct connection) | ±0.05% (±0.1%) | ||
Active Energy (100A ClampCT) | ±0.2%(5A,100A) ±0.5% (other) | ||
Reactive Energy (Direct connection) | ±0.1% | ||
Reactive Energy (100A ClampCT) | ±0.5%(5A,100A) ±1.0% (other) | ||
Error (Harmonic Wave) | |||
Direct Connection | kWh,U, I, P, Q, S | ±0.2%H (H=1+0.01k, k=2~51) | |
Clamp CT 5A/100A | kWh,U, I, P, Q, S | ±0.5%H (H=1+0.01k, k=2~51) | |
Cycle Output Current for 5A CCT’s Self Calibration | 0.05A,0.1A,0.25A,0.5A,1A,2.5A,5A | ||
Error of 5ACCT’s Self Calibration (linear and phase error) | ±0.1% | ||
Clamp CT 500A/1000A | kWh,U, I, P, Q, S | ±1.0%H (H=1+0.01k, k=2~51) | |
Error - Others | |||
Ratio Measurement | ±0.5% | ||
Voltage Influence | <±0.01% | ||
Frequency Influence | <±0.01% | ||
Temperature Influence | <±0.01%/℃ | ||
24h Accuracy Influence | <±0.01% | ||
Harmonic Influence | <±0.01% | ||
Phase angle | |||
Range | - 180°~ 180° | ||
Error | <±0.1° | ||
Frequency | |||
Range | 45 ~ 65Hz | ||
Error | ±0.01Hz | ||
Pulse output | |||
Inner High frequency (CH) | Direct connection | 1.8x109 P/kWh | |
Clamp CT | 1.8x109 *(5/Ie)P/kWh | ||
Low frequency output | Direct connection | 3600P, 36000P, 360000P/kWh(kvarh, kVAh) | |
Clamp CT | 3600P, 36000P, 360000P *(5/Ie)P/kWh(kvarh, kVAh) |
Pulse ratio | 1:1 | ||
Output level | +5V (can be adjusted according to request) | ||
Pulse input | |||
Input Channel | 2 | ||
Input level | 5 ~ 10V | ||
Max Pulse Input frequency | Max. 10kHz | ||
Display | |||
Resolution | 7’’TFT Touch Screen | ||
System | Windows CE | ||
Other | |||
Voltage supply mode | External power, Tested circuit, Battery | ||
Working power supply | AC 55~600V | ||
Voltage Withstand | 4.0kV (voltage ¤t terminals, power supply & low voltage terminals) | ||
EFT(Electrical Fast Transient) | 2.0kV | ||
IP Level | IP51 | ||
Surge | 2.0kV (common mode), 2.0kV (different mode) | ||
Power on Stability Time | < 3mins | ||
Chargeable battery | 11.1V 3000mAh | ||
Power Consumption | <9W | ||
Operation Temperature | Temperature -20℃ ~ +55℃, humidity 40% ~ 95% | ||
Storage Temperature | Temperature -40℃ ~ +80℃, humidity 40% ~ 95% | ||
Dimension (mm) (W×H×D) | Main | 245×150×50 | |
Carry case | 425×336×196 | ||
Weight (kg) | Main | 2 | |
Whole set | 10 |