Add to Cart
Model No. | YC99T-3C |
Meter Position / Accuracy | 3 / 0.05 |
AC Voltage output | |
Range | 57.7V,100V, 220V, 380V 660 |
Adjustment Range | (0-120)%RG (RG is Range) |
Adjust Resolution | 0.01%RG, 0.1%RG, 1%RG, 10%RG |
Stability | 0.01%/2min (0.05cl), 0.02%/2mim(0.1cl) |
Distortion | 0.2% (Non capacitive load) |
Max Output load | 20VA/phase |
Measurement Accuracy | %0.05%RG(0.05cl), %0.1%RG(0.1cl) |
AC Current output | |
Range | 0.05A 0.2A 1A 5A 16.67A 50A |
Adjust Range | (0-120)%RG (RG is Range) |
Adjust Resolution | 0.01%RG, 0.1%RG, 1%RG, 10%RG |
Stability | 0.01%/2min (0.05cl), 0.02%/2mim(0.1cl) |
Distortion | 0.2% (Non capacitive load) |
Max Output load | 50VA(50A range) |
Measurement Accuracy | %0.05%RG(0.05cl), %0.1%RG(0.1cl) |
Power output | |
Stability | 0.01%/2min(0.05cl), 0.02%/2min(0.1cl) |
Active, Reactive power accuracy | %0.05%RG |
Phase output | |
Output adjusting range | 0 ~ 359.99 |
Output adjusting power | 10°,1°,0.1°,0.01°optional |
Resolution | 0.01 |
Measurement accuracy | %0.05 |
Power factor output | |
Adjusting range | -1~0~+1 |
Measuring resolution | 0.0001 |
Measurement accuracy | %0.0005 |
Frequency output | |
Adjusting range | 40Hz – 70Hz |
Output adjusting resolution | 1Hz, 0.1Hz, 0.01Hz, 0.001Hz optional |
Resolution | 0.001Hz |
Accuracy | %0.002Hz |
Harmonic setting | |
Harmonic order | 2nd~63rd |
Harmonic amplitude | 0~40% |
Harmonic angle | 0 ~359.00 |
Harmonic set error | 2nd ~ 31st : %0.1%, 32nd~63rd: %0.2% |
Energy error measurement | |
Active energy basic error limit | %0.05%RD(voltage30V~660V,current0.02A~60A,PF 0.5) |
Reactive energy basic error limit | %0.1%RD(voltage30V~660V,current0.02A~60A,PF 0.5) |
Standard crystal | |
Frequency accuracy | %0.5ppm (leave factory@25 ) |
Frequency stability | %0.1ppm,-20 ~+70 |
Energy pulse input | |
Number of energy pulse input | 3 channels active, 3 channels reactive |
General parameters | |
Power supply | AC220V%15% or 110V%15% |
Frequency | 50Hz~60Hz |
Consumption | 60VA~1000VA |
Environment condition | 20 ~ 30 relative humidity |
Storage environment | -20 ~50 |
Size & Weight | 600mm(L) 400mm(W) 266mm(H), 30kg |
Model No. | YC99T-5C |
Meter Position / Accuracy | 3 / 0.05cl |
AC Voltage output | |
Range | 57.7V,100V, 220V, 380V |
Adjustment Range | (0-120)%RG (RG is Range) |
Adjust Resolution | 0.01%RG, 0.1%RG, 1%RG, 10%RG |
Stability | 0.01%/2min (0.05cl), 0.02%/2mim(0.1cl) |
Distortion | 0.2% (resistance load) |
Max Output load | 20VA/phase |
Measurement Accuracy | %0.05%RG(0.05cl), %0.1%RG(0.1cl) |
AC Current output | |
Range | 0.05A 0.2A 1A 5A 20A 100A |
Adjust Range | (0-120)%RG (RG is Range) |
Adjust Resolution | 0.01%RG, 0.1%RG, 1%RG, 10%RG(optional) |
Stability | 0.01%/2min (0.05cl), 0.02%/2mim(0.1cl) |
Distortion | 0.2% (Non capacitive load) |
Max Output load | 100VA(100A range) |
Measurement Accuracy | %0.05%RG(0.05cl), %0.1%RG(0.1cl) |
Power output | |
Stability | 0.01%/2min(0.05cl), 0.02%/2min(0.1cl) |
Active, Reactive power accuracy | %0.05%RG |
Phase output | |
Output adjusting range | 0 ~ 359.99 |
Output adjusting power | 10°,1°,0.1°,0.01°optional |
Resolution | 0.01 |
Measurement accuracy | %0.05 |
Power factor output | |
Adjusting range | -1~0~+1 |
Measuring resolution | 0.0001 |
Measurement accuracy | %0.0005 |
Frequency output | |
Adjusting range | 45Hz – 70Hz |
Output adjusting resolution | 1Hz, 0.1Hz, 0.01Hz, 0.001Hz |
Resolution | 0.001Hz |
Accuracy | %0.002Hz |
Harmonic setting | |
Harmonic order | 2nd~63rd |
Harmonic amplitude | 0~40% |
Harmonic angle | 0 ~359.99 |
Harmonic set error | 2nd ~ 31st : %0.1%, 32nd~63rd: %0.2% |
Energy error measurement | |
Active energy basic error limit | %0.05%RD(voltage30V~380V,current0.02A~120A,PF 0.5) |
Reactive energy basic error limit | %0.1%RD(voltage30V~380V,current0.02A~120A,PF 0.5) |
Standard crystal | |
Frequency accuracy | %0.5ppm (leave factory@25 ) |
Frequency stability | %0.1ppm,-20 ~+70 |
Energy pulse input | |
Number of energy pulse input | 3 channels active, 3 channels reactive |
General parameters | |
Power supply | AC220V%15% or 110V%15% |
Frequency | 50Hz~60Hz |
Consumption | 60VA~1000VA |
Environment condition | 20 ~ 30 relative humidity |
Storage environment | -20 ~50 |
Size & Weight | 600mm(L) 400mm(W) 266mm(H), 48kg |
1.It can test various single and three phase electronic and
mechanical meters,
2.It can automatically or manually test 1ph or 3ph meters': basic
error, creeping teststarting test, standard deviation and etc,, the
testing plan can be fixed by customers;
3.It can execute the influence test includes: voltage influence,
frequency influence,harmonic influence, reverse phase sequence
influence, unbalance voltage influencetest;
4.Support DLT-645 communication protocol, and can execute some
tests formulti-functions energy meters;
5.More output terminals for more operations: RS232, RS485, extend
l/0, EthernetUSB, wifi and etc.;
6.Output 2~63 harmonics
7.8 inch touchscreen and friendly operation system,
8.It can test 3 pcs meters maX.