Add to Cart
Process Cooling Towers Industrial Cooling Tower High Efficient Square Open Water Chiller System For Building Customized
The comprehensive optimization design causes the YDFH cooling tower to allocate the water, the air flow field to be even, the overall performance achieves best.
Selects the high quality patented filler, the target type sprayer to allocate water, the cooling tower special-purpose use all seal up electrical motor, the width leaf blade special-purpose air blower and the optimization design belt transmission system; The shell uses the FRP compound materials, the color is bright, surface bright and clean, anti-aging, non-fading, causes the cooling tower service long time keep new.
Used the pour water filler with water collector, will drift control water loss in 0.1 percent below, the distribute water sink with cover to prevent contamination of the water cycle; it select wide blades, low-speed fan, to reduce the outlet of the dynamic pressure Loss of energy conservation effectively and environmental protection.
The speed reducer uses imported bearing, the air blower with wide leaf blade, low wind speed, enables the air blower noise to be under the active control; Uses the noise elimination flow divider, the sprayer distribute water and the unique design filler, will reduce the noise of spray water fall lowly.
After Solid Edge the CAD optimization design, the cooling tower maximum limit reduces the area; the tower body structure uses the hot dipping zinc steel skeleton and the FRP compound materials, reduced the tower body weight quantity.
This series cooling tower by the environment wet-bulb temperature τ=28°C, inlet water temperature t1=37°C, outlet water temperature t2=32°C for design operating mode. The noise measuring point is cooling tower equivalent diameter Dm place. And Dm=1.13 (LW) 0.5, are apart from the ground level is 1.5m Our company may carry on the custom design according to the customer request to the cooling tower. |
DFH-80 | DFH-100 | DFH-125 | DFH-150 | DFH-175 | DFH-200 | ||
Water capacity | t=28℃ m3/h | 80 | 100 | 125 | 150 | 175 | 200 |
t=27℃ m3/h | 93 | 119 | 147 | 175 | 205 | 237 | |
Refrigerating Ton(RT) | 115 | 145 | 185 | 225 | 260 | 295 | |
Cooling Efficient*103kcal/h | 400 | 500 | 625 | 750 | 875 | 1000 | |
Power System | Fan Diameter mm | φ1600 | φ1601 | φ1800 | φ2000 | φ2000 | φ2400 |
Power kw*Quantity | 2.2×1 | 3.0×1 | 4.0×1 | 5.5×1 | 5.5×1 | 7.5×1 | |
Dimension | Length | 1850 | 2060 | 2280 | 2580 | 2860 | 3290 |
Width | 3190 | 3190 | 3390 | 3590 | 3590 | 3970 | |
Height | 3420 | 3420 | 3860 | 3960 | 3960 | 4160 | |
Tower lift m | 3.8 | 3.8 | 4 | 4.2 | 4.2 | 4.5 | |
Weight | Dead weight kg | 810 | 855 | 970 | 1175 | 1279 | 1387 |
Operating weight kg | 2177 | 2286 | 2714 | 3088 | 3343 | 3805 | |
Noise dB(A) | 57 | 57 | 58 | 59 | 59 | 60 |
About Shuangyi