Add to Cart
Application | |||||||||
Measuring element | 1 x Pt 1000 + 1 x NTC; (thermically coupled, with backup function (temperature measuring even if one element fails)) | ||||||||
Media | liquids and gases | ||||||||
Pressure rating [bar] | 50 | ||||||||
Minimum installation depth [mm] | 25 | ||||||||
Electrical data | |||||||||
Operating voltage [V] | 18...32 DC; ("supply class 2" tocULus) | ||||||||
Current consumption | [mA] | 6; (24 V) | |||||||
Protection class | III | ||||||||
Reverse polarity protection | yes | ||||||||
Power-on delay time [s] 8 Integrated watchdog yes | |||||||||
Inputs / outputs | |||||||||
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||||||
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — TAD981-03 — 30.05.2017 | |||||||||
TAD981 | |||||||||
Temperature transmitter | |||||||||
TAD033KLES30-A-ZKG/US | |||||||||
Outputs | |||||||||
Total number of outputs | 2 | ||||||||
Output signal | switching signal; analogue signal; IO-Link; (configurable) | ||||||||
Electrical design | PNP/NPN | ||||||||
Number of digital outputs | 1 | ||||||||
Output function | normally open / normally closed / diagnostic signal; (parameterisable) | ||||||||
Max. voltage drop switching output DC | [V] | 2 | |||||||
Permanent current rating of switching output DC | [mA] | 150; (200 (...60°C); 250 (...40 °C)) | |||||||
Diagnostic output | diagnostic output for drift and fault monitoring | ||||||||
Number of analogue outputs | 1 | ||||||||
Analogue current output | [mA] | 4...20 | |||||||
Max. load | [Ω] | (Ub - 15 V) x 50 | |||||||
Short-circuit protection | yes | ||||||||
Type of short-circuit protection | pulsed | ||||||||
Overload | protection | yes | |||||||
Measuring/setting range | |||||||||
Measuring range | -25...160 °C | -13...320 °F | |||||||
Note on measuring range | scalable | ||||||||
Factory setting | 0...150 °C / 32...302 °F | ||||||||
Drift warning | 0.2...5 °C | 0.4...9 °F | |||||||
Drift alarm | 0.2...5 °C | 0.4...9 °F | |||||||
Insteps of | 0.05 °C | 0.1 °F | |||||||
Resolution | |||||||||
Resolution of analogue | [K] | 0.05 | |||||||
output | |||||||||
Accuracy / deviations | |||||||||
Precision analogue output | [K] | ± 0,2 (-10...130°C); ± 0,3 (130...140°C); ± 0,3 ± 0,1% MS
(-25...-10/140...160°C); (probe completely inserted into the measured medium up to the sealing chamfer) | |||||||
Temperature coefficient [% of the span / 10 K] | < ± 0,01; (in case of deviation from the reference condition 25 ± 5 °C) | ||||||||
Response times | |||||||||
Dynamic response T05 / T09 [s] | 3 / 6 | ||||||||
Software / programming | |||||||||
Parameter setting options | drift warning/drift alarm threshold; Fail-Safe; Display unit;
scaling of the analogue output; redundancy switching; performance diagnostic output; switching logic; normally open / normally closed | ||||||||
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — TAD981-03 — 30.05.2017 | |||||||||
TAD981 | |||||||||
Temperature transmitter | |||||||||
TAD033KLES30-A-ZKG/US | |||||||||
Interfaces | |||||||||
Communication interface | IO-Link | ||||||||
Transmission type | COM1 (4,8 kBaud) | ||||||||
IO-Link revision | 1.1 | ||||||||
SDCI standard | IEC 61131-9 CDV | ||||||||
IO-Link device ID | 323 d / 00 01 43 h | ||||||||
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||||||
SIO mode | yes | ||||||||
Required master port type | A | ||||||||
Process data analogue | 1 | ||||||||
Process data binary | 1 | ||||||||
Min. process cycle time [ms] | 18.8 | ||||||||
Operating conditions | |||||||||
Ambient temperature [°C] | -25...70 | ||||||||
Storage temperature [°C] -40...85 Protection IP 68; IP 69K | |||||||||
Tests / approvals | |||||||||
EMC | DIN EN 61000-6-2 | ||||||||
DIN EN 61000-6-3 | |||||||||
Shock resistance | DIN EN 68000-2-27 | 50 g (11 ms) | |||||||
Vibration resistance | DIN EN 60068-2-6 | 20 g (10...2000 Hz) | |||||||
MTTF [years] | 213 | ||||||||
Note on approval | Including free 5-point calibration certificate. | ||||||||
Mechanical data | |||||||||
Weight | [g] | 399 | |||||||
Materials | stainless steel (1.4404 / 316L); PEI; FKM | ||||||||
Materials (wetted parts) | stainless steel (1.4404 / 316L) | ||||||||
Process connection | threaded connection G 1 external thread Aseptoflex Vario | ||||||||
Surface characteristics Ra/Rz of the wetted parts | Ra: < 0.6 | ||||||||
Installation length EL [mm] | 33 | ||||||||
Remarks | |||||||||
Remarks | MS = set measuring span | ||||||||
Pack quantity | 1 pcs. | ||||||||
Electrical connection | |||||||||
Connector: 1 x M12; Contacts: gold-plated |