heatless/micro heat (LH) regenerative adsorption dryer technical parameters | ||||||
model | air treatment(m3/min) | Pipe diameter(mm) | Dimensions(length x width x height mm) | Heating power/power supply (micro heat) | Equipment weight (heatless Kg) | Equipment weight (micro heat Kg) |
BX0005 | 0.8 | DN15 | 600X350X1500 | 70 | ||
BX0010(LH) | 1.8 | DN20 | 650X450X1500 | 0.35/220 | 80 | 95 |
BX0020(LH) | 2.8 | DN20 | 700X450X1500 | 0.5/220 | 100 | 120 |
BX0030 (LH) | 3.8 | DN25 | 900X480X1600 | 0.75/220 | 130 | 140 |
BX0040(LH) | 5.5 | DN40 | 1000X650X1750 | 1.25/220 | 250 | 270 |
BX0060(LH) | 6.8 | DN40 | 1000X700X1800 | 1.5/220 | 280 | 300 |
BX0080(LH) | 8.8 | DN50 | 1100X700X1900 | 2.0/220 | 450 | 480 |
BX0100(LH) | 11.5 | DN50 | 1100X650X2050 | 2.5/220 | 500 | 530 |
BX0120(LH) | 14 | DN65 | 1200X850X2200 | 3.0/380 | 550 | 580 |
BX0150(LH) | 16 | DN65 | 1200X850X2200 | 3.75/380 | 580 | 620 |
BX0200(LH) | 22.8 | DN80 | 1400X1000X2350 | 5.0/380 | 860 | 900 |
BX0250(LH) | 28.5 | DN80 | 1400X1000X2500 | 6.25/380 | 1200 | 1250 |
BX0300(LH) | 35 | DN80 | 1750X1100X2500 | 7.5/380 | 1600 | 1700 |
BX0400(LH) | 45 | DN100 | 1700X1100X2600 | 10/380 | 1900 | 2000 |
BX0500(LH) | 55 | DN100 | 1900X1200X2800 | 12.5/380 | 2300 | 2500 |
BX0600(LH) | 65 | DN125 | 2000X1300X2800 | 15/380 | 2800 | 3000 |
BX0800(LH) | 85 | DN150 | 2200X1600X2900 | 20/380 | 3400 | 3800 |
BX1000(LH) | 105 | DN150 | 2600X1600X2960 | 25/380 | 4100 | 4500 |
BX1200(LH) | 120 | DN200 | 3200X1600X3000 | 30/380 | 4500 | 5000 |
BX1600(LH) | 160 | DN200 | 3800X1800X3000 | 40/380 | 6000 | 6500 |
BX2000 (LH) | 200 | DN250 | 4200X2000X3000 | 50/380 | 7500 | 8000 |
Note: BX0005-BX2000 models are twin-tower traditional structures; (LH) is a low-heat adsorption dryer |
2. Work flow of micro-thermal regeneration adsorption dryer
The micro-thermal regeneration adsorption dryer combines the
advantages of pressure swing adsorption and temperature swing
adsorption, that is, the moisture adsorbed by the adsorbent during
the adsorption process relies on the thermal diffusion and low
pressure of the regeneration gas (heated and dry air) during the
regeneration process. It can be completely eliminated through the
combined action of mechanisms.
Adsorption
The wet air enters the A drying cylinder from the lower pipe
diameter through the A1 valve.
It flows through the adsorbent layer from bottom to top, and the
dried air is discharged from the upper pipe system.
regeneration
A small amount of dry air (about 7%) passes through the upper duct
system to regenerate the air
After the regulating valve is decompressed, it enters the heater
for heating. This part of the hot air (called regeneration air)
enters the B drying cylinder. The adsorbent in the B cylinder is
analyzed and regenerated to restore the drying ability of the
adsorbent. The regeneration gas is discharged into the atmosphere
through the B2 valve and silencer of the lower piping system.
equalize pressure
After the adsorbent regeneration is completed, the B2 valve is
closed, and the B drying cylinder gradually
Gradually increase the pressure to online working pressure and
prepare to switch.
switch
The B1 valve of the lower pipe system is open, the A1 valve is
closed, and the A2 valve is open.
The two drying cylinders A and B are switched, cylinder B enters
adsorption, and cylinder A is depressurized and regenerated. The
working sequence, working time and heating temperature are
automatically controlled by the controller.