Add to Cart
1: Synchronous and asynchronous motor open-loop/closed-loop vector
control, V/F control (with built-in PID).
2: Large torque output to ensure smooth motor start under heavy
load.
3: Powerful function, outstanding performance, suitable for most
general occasions.
4:Supports various types of PG cards.
5:Supports instant stop and instant start.
6:It is compact and easy for customers to install.
7: The voltage range is 220v,380v,415v,440v,460v, and the maximum
power is 450kw.
Item | T9000 series inverter |
Control mode | V/F control;Open loop vector control (without PG); Closed loop vector control (with PG) |
Maximum frequency | 0~600Hz |
Carrier frequency | 0.5kHz~16kHz The carrier frequency is automatically adjusted based on the load features. |
Input frequency resolution | Digital setting:0.01Hz Analog setting: Maximum frequency 0.025% |
Startup torque | G type: 0.5Hz/150%(SFVC) ; P type: 0.5Hz/100% |
Speed range | 1:100(SVC) |
Speed stability accuracy | ±0.5%(SVC) |
Overload capacity | G Type:60s for 150% of the rated current, 3s for 180% of the rated
current. P Type:60s for 120% of the rated current, 3s for 150% of the rated current. |
Torque boost | Auto boost or Customized boost 0.1%-30.0% |
V/F cure | Straight-line VF curve; Multi-point VF curve; N-power VF curve(1.2-power,1.4-power,1.6-power,1.8-power,square) |
V/F separation | 2 types: complete separation;half separation |
Ramp mode | Straight-line ramp ; Four groups of acceleration/deceleration time with the range of 0.00'6500.0s |
Simple PLC, Multiple preset speeds | It implements up to 16 speeds via the simple PLC function or combination of terminal states |
Auto voltage regulation | It can keep constant output voltage automatically when the mains voltage changes |
Rapid current limit | It helps to avoid frequent over current faults of the AC drive. |
Torque limit and control | It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be implemented in the FVC mode. |
Support for multiple PG card | Support for differential input PG card, resolver PG card ,rotating transformer PG card |
Rapid current limit | It helps to avoid frequent over current faults of the AC drive. |
Timing control | Timing range:0.0Min~6500.0Min |
Q1:What is your MOQ?
A: 1 pc
Q2:What's your terms of payment?
A:T/T 100% before delivery.
Q3:What's your delivery time?
A:Generally within 15 days after receiving full payment.
Q4:How can l get OEM/ODM order?
A:If your order quantity meets certain requirements, we are happy
to customize it for you. We have cooperation with more than forty
manufacturers.