SIL 3 HART Multiplexer P+F Sensors Slave KFD0-HMS-16

Brand Name:P+F
Certification:PF 07 CERT 1143 X
Model Number:KFD0-HMS-16
Minimum Order Quantity:1 piece
Delivery Time:on request
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Hong kong China
Address: Unit 1406B 14/F,The Belgian Bank Building, Nos. 721-725 Nathan Road, Mongkok, Kowloon,Hong kong.
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

Multiplexer Slave KFD0-HMS-16


16-channel, No external power required, HART field device input (revision 5 to 7), Used with HART Multiplexer Master KFD2-HMM-16, Up to SIL 3 acc. to IEC/EN 61508


Technical Data


Functional safety related parameters

Safety Integrity Level (SIL)

SIL 3

Supply

Connection

via 14-channel flat cable form master KFD2-HMM-16

HART signal channels (non-intrinsically safe)

Conformity

HART field device input (revision 5 to 7)

Connection

26-pin flat cable for analog connections
14-pin flat cable for master-slave connection between KFD2-HMM-16 and KFD0-HMS-16

Leakage current

< 3 µA at -20 ... 85 °C (-4 ... 185 °F)

Terminating resistor

external 230 ... 500 Ω standard (up to 1000 Ω possible)

Output voltage

≥ 400 mV ss (with the terminator resistance specified above)

Output resistance

100 Ω or smaller, capacitive coupling

Input impedance

according to HART specification

Input voltage range

0.08 ... 4 V ss ; typ. ± 5.2 V as local reference

Indicators/settings

Labeling

space for labeling at the front

Directive conformity

Electromagnetic compatibility



Directive 2014/30/EU

EN 61326-1:2013 (industrial locations)

Conformity

Degree of protection

IEC 60529:2001

Ambient conditions

Ambient temperature

-20 ... 65 °C (-4 ... 149 °F)

Mechanical specifications

Degree of protection

IP20

Mass

approx. 100 g

Dimensions

20 x 93 x 115 mm (0.8 x 3.7 x 4.5 inch) (W x H x D) , housing type B1


Height

93 mm


Width

20 mm


Depth

115 mm

Mounting

on 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

Certificate

PF 07 CERT 1143 X


Marking

II 3G Ex nA IIC T4 Gc

Directive conformity



Directive 2014/34/EU

EN 60079-0:2012+A11:2013 , EN 60079-15:2010


Related Models:


KCD2-SCD-EX1

KFU8-UFT

KCD2-STC-EX1.20

K-HM26-2M-261533

KFD2-SR2-Ex1.W.LB

NBB15-U1-E2

KFD2-SR2-2.W.SM

NBB1,5-5GM25-E2

KFD2-SR2-Ex2.W.SM

NBB1,5-5GM25-E2-V3

KFD2-SR2-Ex2.2S

NBB1,5-F79-E0

KFD2-SR2-2.2S

NBB1,5-F79-E2

KFA6-DWB-EX1.D

NBB15-U1-Z2

KFA6-SR2-Ex2.W

NBB5-18GM50-E2-V1

KFA6-SR-2.3L.FA

NBB15-30GM30-E2-V1

KFA6-ER-1.5

NBB15-30GM50-A2-V1

KFA6-ER-1.6

NBB15-30GM50-E2

KFA6-ER-1.W.LB

NBB15-30GM50-E2-M

KFA6-ER-2.W.LB

NBB15-30GM50-E2-V1

KFA6-ER-Ex1.W.LB

NBB15-30GM50-E2-V1-M

KFA6-SR-2.3L.FA

NBB8-18GM30-E2

KFA6-STR-1.24.4

NBB8-18GM30-E2-V1

KFD0-CS-Ex1.50P

NBB8-18GM60-A2-V1

KFD2-SH-Ex1.T.OP

NJ4-12GK-SN

KFD2-SL2-EX2.B

NJ5-18GK-N

KFD2-SR2-EX1.W

NJ5-18GK-N-150

KFD2-SR2-Ex2.W

NJ5-18GM-N

KFD2-STC5-1.2O

NJ8-18GK-N

KFD2-STC5-Ex1

RD0-FB-EX4

KFD2-STC5-Ex1.H

RD0-TI-Ex8.FF.*

HIC2031

Z787.F



China SIL 3 HART Multiplexer P+F Sensors Slave KFD0-HMS-16 supplier

SIL 3 HART Multiplexer P+F Sensors Slave KFD0-HMS-16

Inquiry Cart 0