Add to Cart
The inductive safety sensors are TÜV-certified in accordance with the EU Machinery Directive, Performance Level PLd, Category 2, and SIL2. They are used to safeguard machines and plant components, as well as for reliable position detection in this environment. With their OSSD interface for reliable, redundant shutdown of electronic outputs, they enable easy connection to a safety PLC or fail-safe control interfaces. They can also be operated as standard sensors. The sensors reliably detect standard metal objects in front of the sensor face without coding or similar; there is no blind zone. High characteristic safety values allow longer testing intervals than comparable solutions with a microcontroller. 2 sensors can be connected with 2-channel redundancy and allow PLe as a Category 3 solution.
Technical Data
General specifications | ||
Switching function | 2 x normally open (NO) | |
Output type | PNP | |
Rated operating distance | sn | 2 mm |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | sa | 0 ... 1.62 mm |
Actuating element | Reference target according EN IEC 60947-5-2 (FE360 - ST37K) 12 mm x 12 mm x 1 mm | |
Reduction factor rAl | 0.6 | |
Reduction factor rCu | 0.45 | |
Reduction factor r304 | 0.9 | |
Reduction factor rBrass | 0.6 | |
Output type | 4-wire | |
Nominal ratings | ||
Operating voltage | UB | 18 ... 30 V |
Rated operating voltage | Ue | 24 V |
Switching frequency | f | 0 ... 30 Hz |
Hysteresis | H | typ. 5% |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Overload resistance | yes | |
Voltage drop | Ud | ≤ 3 V at IL (sum of all outputs) max. 50 mA |
Rated insulation voltage | UBIS | 30 V |
Operating current | IL | 1 ... 30 mA per output |
Off-state current | Ir | 0 ... 0.5 mA |
No-load supply current | I0 | ≤ 15 mA |
Time delay before availability | tv | ≤ 300 ms |
Switching state indicator | LED, yellow | |
Error indicator | LED, red | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Performance level (PL) | PL d | |
Category | Cat. 2 | |
MTTFd | > 7500 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | min. 60 % | |
Assured release distance of a PDDB | Sar | 3 mm |
Connection