FGM1190 Variable Area Flowmeter Glass Tube VA Flowmeter

Brand Name:ABB
Model Number:FGM1190
Accuracy:High
Communication Protocol:HART, PROFIBUS, FOUNDATION Fieldbus
Fluid:Gas, Liquid
Installation Type:In-line, Insertion
Contact Now

Add to Cart

Verified Supplier
Location: Suzhou China
Address: Room 101, Building 19, No. 4388 Dong Shan Avenue, Lin hu Town, Wu Zhong District, Suzhou, China zip 215106
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details

Glass tube variable area flowmeter FGM1190

The wide variety of float weights and meter tubes allows the glass tube flowmeter FGM1190 to be matched exactly to the required flow range. The three ribs, parallel to the center axis of the meter tube, guide the float over the entire flow range. This enables a high degree of reproducibility because the float is absolutely centered in the meter tube.


Overview

Designed for flowrate measurements in many industries including system manufacture, food, water treatment plants and chemical. Aggressive fluid applications are possible because the fluid wetted parts can be made from a wide variety of different materials.

  • Design type FGM1190-87
    – With threaded pipe connection in accordance with DIN 2950.
  • Design type FGM1190-97
    – With vertical internal thread connection or threaded connector in accordance with
    DIN 11851, DIN 405 part1 for the food and beverage industry.
  • Design type FGM1190-98
    – With flange connection in accordance with DIN and ASME.
  • Easy range change and cleaning-no removal from the line required.
  • Excellent visibility of flow rate over a linear scale.

Data

General specifications:

  • Application
    – Clean, low viscosity liquids and gases
  • Mounting
    – Vertically, in line
  • Connections
    – 1/4 in. to 2 in., threaded, DN 10 to DN 50 flanged, SC15 to SC50 hygienic (DIN11851), vertical
  • Flow ranges
    – Water flows: 0.002 to 17600 l/h
  • Flow turndown
    – Typically 10:1
  • Operating pressure
    – Up to 18 bar (261 lbf/in 2 g)
  • Operating temperature
    – Up to 180 °C (356 °F)
  • Nominal scale length
    – 100, 130 or 250 mm (4, 5 and 10 in.)
  • Accuracy
    – Class 1.6 to Class 6, depending on tube diameter and float type
  • Alarms
    – Inert gas switches, up to 2 off
  • Tube material
    – Borsilicat glass
  • Float material
    – Stainless steel, Glass, Sapphire, Carboly, PVC, Tantalum, HastelloyTM, Aluminium, PTFE
  • Fitting material
    – Stainless steel, PVC, PVDF

China FGM1190 Variable Area Flowmeter Glass Tube VA Flowmeter supplier

FGM1190 Variable Area Flowmeter Glass Tube VA Flowmeter

Inquiry Cart 0