Differential Pressure Transmitter With Diffused Silicon Piezoresistive Dwyer Differential Pressure sensor

Brand Name:HT SENSOR
Certification:ISO9001
Model Number:BP93420D-II
Minimum Order Quantity:1
Delivery Time:5-8 workday
Payment Terms:L/C, D/P, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Baoji Shaanxi China
Address: Building 4, No.195, Gaoxin Avenue, Weibin District, Baoji City, Shaanxi Province, China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

Differential Pressure Transmitter With Diffused Silicon Piezoresistive Dwyer Differential Pressure Sensor

BP93420DII Differential Pressure Transmitter


Introduction of differential pressure transmitter:


The BP93420DII differential pressure transmitter employs a diffused silicon piezoresistive sensor. The pressure differential of gas and liquid is measured and outputted, which can be displayed. It is applicable to the measurement of pressure differential of various gases and liquids in pipelines within industries such as petroleum, chemical, electric power, hydrology, etc.


Product Features of differential pressure transmitter:

  1. The transmitter adopts stainless steel structure design, compact structure and easy installation.
  2. After strict temperature compensation and aging screening, to ensure stable and reliable performance.
  3. The electrical interface can be external or direct connection.​

Applications of differential pressure transmitter::

  • 1. Suitable for the differential pressure measurement of various gases or liquids in pipelines in petroleum, chemical, electric power, hydrology and other industries.
  • 2. Used in industrial field process control.
  • 3. Pipe and furnace differential pressure measurement.​ers

Performance Parameters of differential pressure transmitter:
Measurement Range0-10KPa……~2MPa
Pressure TypeDifferential Pressure
Single-side Overload≤3 times of the rated range
Static pressureThe minimum value between 5 times the rated range or 7 MPa
Accuracy @ 25℃±0.25% (Typical) ±0.5% (Maximum)
Repeatability±0.03% (Typ.) ±0.05%FS (Max.)
Hysteresis±0.03% (Typ.) ±0.05%FS (Max.)
Long-Term Stability±0.5%F.S/Year(≤200KPa) ±0.2%F.S/Year(>200KPa)
Zero Temperature Drift±0.01%FS/℃(>100KPa), ±0.02%FS/℃ (≤100Kpa)
Span Temperature Drift±0.01%FS/℃(>100KPa), ±0.02%FS/℃ (≤100Kpa)
Compensation Temperature0-50℃(0-10KPa, 0-20KPa) ,0-70℃ ,-10-70℃
Operating Temperature-30℃~80℃
Storage Temperature-40℃~100℃
Vibration10g,55Hz ~ 2kHz
Housing Material304,316L
Diaphragm Material316L
Insulation Resistance100MΩ 100VDC
Explosion-proof RatingIntrinsically safe and explosion-proof
Protection RatingIP65
Weight~0.45kg

Output SignalSupply VoltageOutput Type
4~20mA12~30VDC2/3/4 wire
0~10/20mA

3 wire

0/1~5V
0.5~4.5V5VDC


Ordering tips of differential pressure transmitter:

1. When selecting the product, please ensure that the test medium is compatible with the contact parts of the product (stainless steel 304 or 316L).
2. In order to ensure reliable operation, it is recommended to install three valve tubes between the measuring point and the transmitter to ensure that the pressure of the positive and negative pressure chamber of the transmitter is slow and uniform. If the overload of a single end is serious, the sensor will be damaged.
3. When installing, the pressure interfaces at both ends should be placed horizontally to minimize the impact of the installation position on the product.
4. In case of special requirements such as strong vibration, instantaneous shock, strong electromagnetic interference or radio frequency interference, please inform us and indicate in the order.

5.When ordering a transmitter with an LCD or LED display head, the power supply of the transmitter should not be lower than 20VDC.


Order Guide of differential pressure transmitter:
BP93420XXPressure Transmitter
CodeOutline Construction
DIIDifferential Pressure Transmitter
Measurement Range0-10KPa……~2MPa
CodePower Supply
D124VDC
D25VDC
D3Other
CodeOutput Signal
S14~20mADCS50~20mADC
S21~5VDCS60~10VDC
S30~5VDCS70.5~4.5VDC
S40~10mADC
CodePressure Connection
J1M20×1.5 Male
J2G1/2 Male
J3G1/4 Male
J41/2 NPT Male
J5Other
CodeElectrical Connection
B1Hirschmann
B2PG7 Plug
B3Sealed Cable Output
B4Other
CodePressure Type
DDifferential Pressure

FAQ:


Q1:Are you manufactrade company?

A1:We are manufactrader with more than 29 years of experience.


Q2:Customized Product

A2:We provide OEM and Custom-Design services.


Q3:Quality Quarantee

A3:Our products have a limited 12 to 18 months warranty from shipment date to the original purchaser.Hengtong will replace or repair defective products free of charge.This warranty does not apply to any units have been modified,misused,neglected.


Q4:Shipment&packing

A4:Products are generally shipped by international Express including UPS,FedEx,DHL and INT for freight prepaid,also can use your shipment account to collect,Standard export packing,including inspection certification.


Q5:Contact US

A5:We have an active and experienced sales team to serve you on technical question and business issue.Just leave us message or click the Online Service.

China Differential Pressure Transmitter With Diffused Silicon Piezoresistive Dwyer Differential Pressure sensor supplier

Differential Pressure Transmitter With Diffused Silicon Piezoresistive Dwyer Differential Pressure sensor

Inquiry Cart 0