There are two types of air-cooled chillers and water-cooled
chillers. The chillers are divided into low-temperature chillers
and normal-temperature chillers in terms of temperature control.
The normal temperature is generally controlled within the range of
0 degrees to 35 degrees. The temperature control of the cryogenic
machine is generally in the range of 0 degrees to minus 45 degrees.
chiller
In the refrigerant cycle system, the liquid refrigerant in the
evaporator absorbs the heat in the water and begins to evaporate.
Finally, a certain temperature difference is formed between the
refrigerant and the water. The liquid refrigerant is also
completely evaporated into a gaseous state and then sucked and
compressed by the compressor. The gaseous refrigerant releases heat
through the condenser, condenses into a liquid, and becomes a
low-temperature and low-pressure refrigerant after throttling
through the thermal expansion valve and enters the evaporator to
complete the refrigerant cycle process.
1. All pipeline insulation design to prevent local convection of
the body pipeline. The cooling temperature range is 5°C-35°C, and
the independent temperature controller is antifreeze protection.
2. Stainless steel heat preservation water tank.
3. Hydrophilic light-fin condenser, better heat transfer effect and
faster heat dissipation.
4. Both compressor and pump have overload protection.
5. It adopts large-capacity shell-and-tube evaporator, which has
good cooling effect and is suitable for high-temperature
environments.
6. The refrigerant is R22, which has good cooling effect.
7. Optional R407C environmentally friendly refrigerant, closer to
nature.
Product Name | Technical Parameters |
---|---|
Industrial Water Chiller | Evaporator: Shell And Tube/Plate Heat Exchanger Cooling Medium: Water/Glycol Controller: PLC/Microcomputer Noise Level: ≤65 dB(A) Cooling Capacity: 5-2000 KW Voltage: 220V/380V/440V/480V/600V Cooling Method: Air/Water/Evaporative Design Temperature: -20℃~+20℃ Condenser: Shell And Tube/Plate Heat Exchanger |
⒈The chiller can be used in the matching vacuum equipment. This
type of chiller also meets the needs of high-quality vacuum
equipment, such as molecular pumps, small vacuum coating machines,
etc.
2. The chiller is used in supporting medical laser equipment. The
unique water quality treatment characteristics of this type of
chiller make it an ideal choice for medical laser equipment and
supporting laboratory equipment. This series of chillers are also
widely used in atomic absorption spectrometers, fermentation
devices, reaction kettles, electrophoresis instruments, etc.
During the use of the chiller, you must pay attention: firstly,
liquid medium should be added to the tank before use, and then the
working power supply should be determined according to the model of
the machine. The power supply should be greater than or equal to
the total power of the instrument, and the power supply must have
good grounding. The chiller should be placed in a dry and
ventilated place, and then the side of the chiller should be 400mm
away from the obstacle. Finally, after using the chiller, all
switches should be turned off, and the power plug should be
connected. Liquid blotted dry.