KFZ Load and No Load Loss Testing Transformer Test Equipment

Introduction:

  • KFZ Load and No Load Loss Testing Transformer Test Equipment can measure transformer capacity, type, no-load current, no-load loss, short circuit (load) loss, resistance voltage, etc.

  • KFZ Load and No Load Loss Testing Transformer Test Equipment is small in volume, light in weight, in high accuracy, with steady property, easy to operation can replace the traditional testers.

  • KFZ Load and No Load Loss Testing Transformer Test Equipment is displayed by LCD, operated by menu, with friendly interface, is the first choice for all customers.


Features:

  • KFZ Load and No Load Loss Testing Transformer Test Equipment can accurately measure capacity of distribution transformer , convenient and accurate;

  • Automatically check if the wire was correctly connected, and display vector diagram of three phase current, voltage when test three phase transformer;

  • KFZ Load and No Load Loss Testing Transformer Test Equipment can do loading test for substation transformer under 1000KVA; can do loading test with 1/3 of the rated current for substation transformer under 3150KVA (the device can convert to the loading losses parameters if the rated current under 1/3 of the rated current);

  • Polarity testing: single phase power transformer, three phase power transformer, CT, PT;

  • Vector group testing: three phase power transformer;

  • All the related test results are automatically corrected, such as: the waveform correction, temperature correction, non-rated voltage correction, calibration, and other non-rated current correction, so test result is more accurate.

  • Can preset 40 groups parameters of testes objects, and these parameters can be deleted or added at any time as needed, so it is easy for use.

  • With electronic clock, auto record the data, time, it is good for saving and managing the test results. With built-in printer;

  • Data (specimen setting, test results, measurement time) can be saved on power failure and can be reviewed, it can store 500 groups test results, can connect with computers to transmit data.

  • Allowance external connecting CT and PT to make extension measurement, can test the specimen with any parameters.

.

Parameters:

Current output

0 ~ 10A

Voltage measurement

0 ~ 10V

Test Capacity

10KV oil-immersed, dry-type transformers: 30KVA ~ 2500KVA

35KV oil-immersed transformers: 50KVA ~ 31500KVA

20KV dry type transformers: 50KVA ~ 2500KVA

35KV dry type transformers: 50KVA ~ 2000KVA

Voltage

0~450V (phase voltage), 0 ~ 800V (line voltage), auto-switch the measurement range

Current

0 ~ 100A, auto-switch the measurement range

Frequency

45Hz ~ 65Hz

Voltage Accuracy

20 ~ 100V, ± 0.2% FS; 100 ~ 450V, ± 0.2%

Current Accuracy

0.5 ~ 10A, ± 0.2% FS; 10 ~ 100A, ± 0.2%

Power Accuracy

± 0.5% (CosΦ> 0.1), ± 1.0% (0.02 <CosΦ <0.1)

Dielectric strength

The insulation resistance between voltage, current input terminal and the chassis≥100MΩ.

Between power supply input terminal and the shell can withstand 2KV (rms), for 1 minute

Dimension

400×300×170mm

Weight

6kg (not including test lines)

Working Temperature

-5°C~40°C

Working Humidity

<95%(25°C)

Altitude

<2500m

Power supply

220VAC±10%,45Hz~55Hz.