JF-2004 Easy Use Portable Transformer Partial Discharge Detector

Brand Name:Delta
Certification:ISO9001
Model Number:JF-2004
Minimum Order Quantity:1 set Partial Discharge Detector
Delivery Time:Within 10 days after the order is confirmed
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Chongqing Chongqing China
Address: No.85 Zhong Shan Yi Road, Yu Zhong District, Chongqing, China. 400010
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

JF-2004 Easy Use Portable Transformer Partial Discharge Detector


Introduction:

The detector is used for the detection and evaluation of the insulation status of high-voltage switchgear, ring network cabinets, transformers, GIS, overhead lines, cable terminals, cable branch boxes, and other equipment.


It is widely used in the following fields:

  • Development and distribution enterprises
  • Railway system
  • Petrochemical power supply system
  • Aerospace testing field
  • Automatic testing field

Partial discharge intensity detection: By measuring the discharge signal within a power frequency period, the intensity of partial discharge is characterized according to the maximum value (dB) in the discharge pulse sequence.

Partial discharge frequency detection: The device measures the discharge signal within a power frequency period, extracts discharge pulses, and characterizes the frequency of partial discharges according to the number of discharge pulses.


Main Features:

  1. Configure different sensors to realize partial discharge detection of almost all electrical equipment;
  2. The humanized man-machine interface facilitates data management of different devices, including traceback of historical data change trends, and horizontal and vertical data analysis, and realizes 360 ° comprehensive diagnosis of the device under test;
  3. Built-in ultrasonic sensors and transient ground voltage (hereinafter referred to as TEV) sensors, which can be connected with special sensors such as transformers, GIS, overhead lines, and cables;
  4. Adopt a non-intrusive detection method, no power failure during the test, and maybe no high voltage source is applied, which is more convenient to use than a traditional pulsed partial discharge detector;
  5. The test bandwidth range is 30kHz ~ 2.0GHz, suitable for the detection principle of various frequency bands;

Parameters:

TEV measurementUHF measurement
Measuring range0-60 dBmVdetection frequency300-2000MHz
Resolution1dBmeasurement range0-60 dBmV
Accuracy±1dBaccuracy<1dBmV
Maximum pulse per cycle1400Sensor band300-2000MHz
Measurement frequency band3~100MHz
AA measurementAE measurement
Measuring range-6dBμV - 68dBμVMeasuring range-6dBμV - 68dBμV
Resolution1dBResolution1dB
Accuracy±1dBAccuracy±1dB
Sensor center frequency40 kHzFrequency range20~200 kHz
HFCT measurement
Sensor transmission impedance5mV/mA
Detection frequency1~30MHz
Sensitivity≤50pC
Hardware
ShellABS
Display4.0 inch RGB LCD screen
ControllerARM
Connector

USB interface (also charger input) 3.5mm stereo headphone jack

External ultrasonic sensor input wireless wifi Wireless synchronization benchmark

Earphoneminimum 8 ohm
SD cardstandard 16G
Built-in battery3.7V/1Ah lithium battery
Working timeabout 8 hours
ChargerAC 90-264V or DC 5V
Operating temperature-20 ~ 50℃
Humidity20-85% relative humidity
Weight0.4KG(host)