Oltc Automatic Transformer on Load Tap Changer Tester

Brand Name:Delta
Certification:ISO9001
Model Number:OLTC
Minimum Order Quantity:1 set Relay Tester
Delivery Time:10 days
Payment Terms:Western Union, T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Chongqing Chongqing China
Address: No.85 Zhong Shan Yi Road, Yu Zhong District, Chongqing, China. 400010
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

Oltc Automatic Transformer on Load Tap Changer Tester

Introduction:

OLTC Automatic Transformer On Load Tap Changer Tester can record switch operation waveform in overall process. The longest time is 6.4s.

OLTC Automatic Transformer On Load Tap Changer Tester can test various parameters such as transition waveform, transition time, transition resistance and three phase synchronization one time and analyze results automatically.

OLTC Automatic Transformer On Load Tap Changer Tester has power-off protection, over-voltage protection, perpetual clock and high-speed printing.

Features:

Test transformers of type Y0 Y Δ and display resistance value directly.

Automatically analyze waveform fault and mark the fault.

Automatically adjust resistance value and time range according to sampling data.

Transformer type Δ is able to display to synchronization status of three phase.

Be able to test with winding or without winding.

Four terminal connection mode and provide high accuracy of resistance measurement.

Continuous test to save time of power off.

Make word report.

800×480 colorized LCD with touch screen and high speed printer.

Store 1000 groups of data and also can be saved by USB flash disk.


Parameters:

meOLTC High Quality Electrical Testing on Load Tap Changer Tester Oltc
Three phase constant current source chargeThree phase constant current source charge
Maximum voltage of the port24V
Maximum range of transition resistance100Ω
Measuring range1A: 0.4Ω~20Ω 0.2A: 10Ω~100Ω
Record time of waveform300ms
Sample rate30k
Resolution of time0.1ms
Resolution of resistance0.1Ω
Accuracy of transition resistance±5% Reading±0.1Ω
Accuracy of transient time±0.5% Reading±0.2mS
Temperature-10-40°C
Humidity<85%RH

Oltc High Quality Electrical Testing on Load Tap Changer Tester Oltc Testing​Real Picture:




China Oltc Automatic Transformer on Load Tap Changer Tester supplier

Oltc Automatic Transformer on Load Tap Changer Tester

Inquiry Cart 0