KFZ-I Power Transformer Capacity, Load and No Load Loss Tester


Introduction:

  • Power transformers an important electrical equipment, and their safe and reliable operation is extremely important for power systems.
  • After the impact of a short-circuit current, the transformer winding deformation test is very important.
  • To short-circuit the low-voltage winding side of the transformer and apply a low voltage of the operating frequency (50Hz or 60Hz normally) to the high-voltage winding side of the transformer, the short-circuit impedance method measures the short-circuit impedance of the operating frequency.
  • The test result is mainly leakage reactance component, determined by the geometry of the winding.
  • The change of the transformer winding structure will cause changes in the transformer leakage reactance, resulting in transformer short circuit impedance numerical changes.
  • KFZ Power Transformer Excitation Current, Capacity, Load Loss Tester follows the national power industry standards DLT 1093-2008, and can be used for IEC60076-5-2006.
  • KFZ Power Transformer Excitation Current, Capacity, and Load Loss Tester can also be used for generator rotor AC impedance test, transformer load, and no load loss test.

Specifications:

  • Using six channels of AD chip of 16 bits;

  • With a 7-inch LCD touch screen which the brightness can be adjusted;

  • With a thermal printer the print thick can be adjusted;

  • It could store fifty groups of SCI data and thirty groups of GAI data, which could be read to the current screen or uploaded to the PC;

  • With PC software using which we could upload data, test, analyze data, print data, or create Word document;

  • Using USB2.0 to connect to the device;

  • Tester dimension: 49*31*25cm;

  • Weight: 8.0KG;

  • Power: AC220V±10%, (50 or 60)HZ ;

1Working powerInput voltage185Vac~250Vac
Allowable input voltage85Vac~264Vac
Frequency50/60Hz
Allowable frequency45Hz~65Hz
Input power40VA
2AC voltageRange10~650V
Resolution0.001V
Accuracy0.2%±0.001V
3AC CurrentRange0.5~60A
Resolution0.001A
Accuracy0.2%±0.001A
4FrequencyRange45Hz~65Hz
Resolution0.001Hz
Accuracy0.2%±0.001Hz
5PowerRange0~39kW
Resolution0.001kW
Accuracy<±0.5%
6Capacity test range10kV Dry type transformer30kVA~3150kVA
10kV Oil immersed transformer30kVA~3150kVA
35kV Oil immersed transformer50kVA~31500kVA
20kV Dry type transformer50kVA~2500kVA
35kV Dry type transformer50kVA~2000kVA
7EnvironmentOperating temperature-10℃~+50℃
Storage temperature-25℃~+70℃
Relative humidity5%~95%
8Dimension40cm*30cm*22cm
9Weight≈8kg (Excluding accessories)