CCT Visible Smoke Release Rate Testing Machine Cone Calorimeter

Introduction:

  • The CCT Visible Smoke Release Rate Testing Machine is designed and manufactured according to international standards and mainly for building products and electric cable testing.

  • The analysis cabinet of our CCT Visible Smoke Release Rate Testing Machine can be moved, it can be used for cone calorimeter test, and CCT Visible Smoke Release Rate Testing Machine can also be used in the large heat release rate test system such as Single Burning Item(SBI), cable burning test system, etc.


Features:

  • Integrated body and 19” analysis rack, 15” touch screen panel type PC for the whole control and automatic testing

  • Auto Split Shutter automatically opened to transmit radiation to the sample, Automatic Spark Igniter to facilitate measurement of ignition time.

  • Load Cell -mass measurements are conducted via a strain gauge load cell with an accuracy of 0.1g. Fitted with a quick electronic tare facility and mechanical stops to avoid movement damage, give stable results and long life.

  • Exhaust System - manufactured from stainless steel for long life. This comprises, hood, gas sampling ring probe, exhaust fan (with adjustable flow controls from 0-50g/s, at a resolution of at least 0.1g/s) and an orifice plate flow measurement (thermocouple and differential pressure transducer). Normal operation is at a nominal 24 l/s.

  • ABB Gas feed unit, Model SCC-S, including 1 gas path, condensate monitor, pump and flow controller with needle valve Peltier cooler and condensate pump. SCC-S can remove water automatically.

  • ABB EL3020-Uras26+ Magnos206, CO 0-1%, CO2 0-10%, automatic calibration of CO & CO2, does not require the use of mixture of CO&CO2 gas. O2 0-25%, Only once a month is used to calibrate the zero point with the nitrogen,

  • Smoke Obscuration - measured with a laser system, using photodiodes, and a 0.5 mW Helium Neon laser, with main and reference (compensating) photo detectors. Supplied with alignment cradle and 0.3, 0.8 neutral density filters for calibration.

  • Medtherm Heat Flux Meter - for setting the irradiance level at the surface of the specimens, the range from 0-100KW/m2.

  • Calibration Burner - to calibrate the rate of heat release measured by the apparatus using methane of 99.5% purity.

  • Methane MFC, to control the flow rate of Methane automatically.

  • OMRON PLC to control all movement such as Split Shutter, Spark Igniter etc.

  • Provide the Self circulation cooling water to cool heat flux meter, without External tap water.

  • DAQ(Data Acquisition) Program controllable with the touch screen panel PC

  • Provide 10units of PMMA samples for comparison testing.


Parameters:

No.Item NameCCT Visible Smoke Release Rate Testing Machine
1Dimension1800mm (W) x 900mm x (H) x 2600mm (D)
2Weight350kg
3Power supply220V, 10A, 50Hz,
4Ambient temperature10 ~ 35 Centigrade
5Working gasCompressed air
6Calibration gasCH4, N2, CO2/CO mixed gas

CCT Visible Smoke Release Rate Testing Machine Real Picture: