RFP Floor Insulation Material Critical Radiant Flux Tester

  • RFP Floor Insulation Material Critical Radiant Flux Tester is the cornerstone of the flooring materials reaction to fire tests in the Euroclass system.

  • RFP Floor Insulation Material Critical Radiant Flux Testermeasures the spread of flame of the sample, under thermal exposure, using a radiant heat ignition source. The thermal exposure is that of a fire growing in the room of origin that through a door opening, radiates onto the floorings in an adjacent room or corridor.

  • RFP Floor Insulation Material Critical Radiant Flux Tester can also be used for tests to standards ASTM E648 and DIN 4102; Part 14.


Standards:

  • ISO 9239-1: Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source;

  • ASTM E648- 17: Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source;


Application Field:

  • Building Materials;

  • Rail;

  • Automotive interior;

  • Others;


Features:

  • The resulting test chamber is insulated with calcium silicate insulation board and is provided with a temperature resistant observation window.

  • The stainless steel sample support assembly is mounted on a sliding platform to allow safe and easy loading of the test sample.

  • The radiant heat is applied by means of a gas-fuelled panel, inclined at 30º, and directed at a horizontally mounted floor covering system specimen.

  • The radiant panel generates a radiant energy flux distribution ranging from a nominal maximum of 10.9 kW/m2 to a minimum of 1.1 kW/m2.

  • Dummy calibration specimen with holder, calibrated heat flux meter and mounting.

  • The distance burned until flame-out is reached and converted, by calibration, into an equivalent critical radiant flux, in kW/m2.

  • Heat Flux Meter: Range 0 ~ 50 kw/m2; Surface emissivity: ε=0.95± 0.05

  • A smoke measuring system, according to DIN 50055, is mounted on a separate frame at the exhaust stack.

  • Control Rack for convenience in use, allowing observation of the apparatus and controls during equipment set-up and calibration.

  • Automatic ignition of the radiant panel and safety cut-out.

  • Automatic moving T type ignition burner

  • Stainless steel hood with smoke measurement ports.


Parameters:

No.

Item Name

ISO 9239-1 Building Material Flooring Radiant Panel Tester

1

Dimension

1900mm (W) x 750mm x (H) x 2120mm (D)

2

Weight

235kg

3

Power supply

230 volts Nominal 10 Amps

4

Ambient temperature

Operating 10oC to 35oC

5

Burning gas

Propane

6

Auxiliary gas

Air compressor gas



Flooring Radiant Panel Tester Real Picture: