Add to Cart
SUMMIT ANT OMS-830 voltage AC220V current analog voltage current
analog electronic intelligent load weighing control unit
Application:
Overload Controller is very useful for the protection of elevator
controlling machines and inverter It eliminates the Risk of over
Loading inside the Lift thereby avoiding accidents by giving
preventive control output to Main Control Unit, usually it is used
with combination with our all kinds of compression load cells and
convert to the complete set of elevator load weighing system.
Features:
Control Unit:OMS-830 | |||
Operation Voltage | AC220V | Sensor operation voltage | DC5V |
Nominal power | 4W | Signal Hold Voltage | AC/DC12-45V |
Input Channel (Load Cell ) | 2 | Measuring precision | 0.1% |
Relay Number | 6(overload,full,half, empty,rope loose,rope deviation) | Operation temperature | -45degree-+85degree |
Contact Load | 8A250VAC,5A 250VAC,5A 30VDC | Size | 90x77.5x59mm |
Display Type | 4 digits 0.56 inch LED | Weight | 218g |
Display mode | Weight/percentage | Shell material | ABS |
The load weighing control unit OMS-560 size:
Elevator load weiging control unit parameters data sheet
Model | OMS-560 | OMS-520 | OMS-820 | OMS-830 | OMS-860 |
Load cell number | 2 | 1 | 2 | 2 | 2 |
Overload | 2NO/1NC | 1NO/1NC | 1NO/1NC | 1NO/1NC | 1NO/1NC |
Full load | 1NO/NC | 1NO/NC | 1NO/NC | 1NO/NC | 1NO/NC |
Half load | / | 1NO/NC | 1NO/NC | 1NO/NC | 1NO/NC |
Light load | 1NO/NC | 1NO/NC | 1NO/NC | 1NO/NC | 1NO/NC |
Display mode | 4digits 0.56inch | ||||
Signal hold | 12-240V | ||||
Floor compensation | / | Y | / | / | / |
Voltage analog output | / | Y | Y | Y | / |
Current analog output | / | optional | optional | optional | / |
Canbus | / | / | / | / | Yes |
Operation voltage | AC/DC18-48V | AC/DC18-48V | AC/DC18-48V | AC220V | AC/DC220V |
Specialty | Optical& acoustic output | / | rope loose | rope loose, 15kg output | rope loose |
Instruction:We, SUMMIT, as a leading elevator components company in China, provide a simple yet powerful range of load weighing control instrumentation. They work with a wide range of load sensor produced by us and can be easily configured using our straightforward, step by step, set up procedure. Calibration is simple and can be achieved with no weight, known weight or full load weight and so on.