Product parameter
Temperature control range :-50°C to +110°C
Temperature measurement accuracy :0.1C
Temperature input :NTC(10K 0.5%)waterproof thermometer
Temperature output :1 10A relay
Return error accuracy :0.1°C
High temperature protection :0-110°C
Resolution:0.1°C when -9.9 to 99.9,1C otherwise
Input voltage :DC12V
Refresh frequency :0.5s
Power consumption: static current <35mA, suction current
<65mA
Display type:028"red/blue three-digit digital tube
Module size :49*40mm
Matters needing attention:
In order to avoid the danger of oversetting the temperature due to
misoperationby others, the thermostat has the upper limit function,
which limits the settingrange of the maximum temperature setting
point controlled by the thermostat. Press +- to switch to P2. Press
SET once to SET the upper limit. Press +- to SETthe temperature
that can be SET by the peak value. For example, if it is set to60,
the peak value of the temperature setting point can only be set to
60° C.To expand the range of the temperature setting point, you
need to adjust theupper limit
P3 Setting Lower Limit for Low Temperature:
In order to avoid ice blockage caused by misoperation of others, the thermostathas the function of setting the lower limit, which limits the setting range ofthe setting point of the low limit temperature controlled by the thermostat. Long press SET5 seconds to display PO press +- to switch to 3 press SET once toset the lower limit, press + 1 to set the temperature that can be set at thepeak. The minimum value is -50. After the setting is complete, press SET once toreturn and hold down SET or 10 seconds without key action. The controllerautomatically confirms that the setting is complete. For example, Set thetemperature setting point to 2
P4 Temperature correction :
When the measured temperature is different from the standard
temperature or theuser hardware has special needs, this function
can be used for correction. Thetemperature after correction = the
temperature before correction + the effectiverange of correction
is-7.0~7.0(unit C).Long press SET for 5 seconds to display PO,
press + everything to change to P4press SET once for correction,
press +- to SET the correction value, press SETonce to return after
completion, long press Set or 10 seconds without press
thecontroller to automatically confirm completion.