MEIAL 900Ton/M Automatic Anodizing Line Process Operation Type

Brand Name:MEI-AL
Model Number:APL-900T
Minimum Order Quantity:1set
Delivery Time:180-200days
Payment Terms:T/T
Place of Origin:CHINA
Contact Now

Add to Cart

Verified Supplier
Location: Foshan China
Address: No. 1, Changgang North Road, Changhongling Industrial Park, Shishan Town, Nanhai City, Foshan City
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

MEIAL 900Ton/M Automatic Anodizing Line Process Operation Type

一.Product Description

1. The anodizing production line strives to improve energy efficiency by implementing heat recovery system, optimizing process parameters, using energy-saving equipment and other energy-saving measures.
2. The anodizing line has developed a waste management strategy to deal with the by-products and waste generated during the anodizing process.

3. Anodizing production lines can be combined with automation and robotics to improve process efficiency and consistency.

二. Design Condition

1AlloyAluminium 6061 to 6063 or others
2Anodizing film thinkness10~ 12µm m
3Average coverage area350m²/T (ton)
4Max aluminium profile length6500mm
5Extrusion ratio2.5kg/m²
6Working hour/m300d/m x 20h/d = 600h/m
7Racking systemTwo fixtures /rack
8Racking operationManual
9Equipment Usage Rate0.9
10Power supplyAC 3phase 380v 50hz
11Control PowerAC220V 50Hz
12Water supply2kg/cm²·G
13Hot steam6kg/cm²·G
14Compressor air6kg/cm²·G

三.Process Tank

1Degreasing 【Free sulfuric acid 180±30 g/l】1 Tank
2Alkaline Etching【Free alkali 40-60g/l,Al3+ 30-120g/】2 Tanks
3NeutralizationFree sulfuric acid180±20g/l】1 Tank
4Anodising 【Free sulfuric acid 140-180g/l,Al3+≤20g/l】4 Tanks
5Colouring 【stannous sulfate 3-8g/l,Free sulfuric acid 15-25g/l,PH 0.8-1.2】2 Tanks
6Medium Temperature Sealing【PH 5-6.5,Nickel ion0.8-1.3g/l,Fluorion0.3-0.7 g/l】3 Tank

四.Treatment Process:

  1. Degreasing
    (1) 6jig(rack)/ tank x 1 tank
    =6jig(rack)
    (2) treatment time: 2-5min
  2. Alkaline Etching
    (1) 6jig(rack) / tank x 2 tank
    =12jig(rack)
    (2) treatment time: 3-15min
  3. Neutralization
    (1) 6jig(rack) / tank x 1 tank
    =6jig(rack)
    (2) treatment time: 1-5min
  4. Anodizing
    (1) 2 jig(rack)/tank x 4tanks = 8jig(rack)
    (2) Current density: 130A/m²
    (3) Process time: 30min
    (4) Unprocess time: 10min
    (5) Total time 30+10=40min

(6) Average anodizing layer : 0.3*1.3*30*0.77 =10.81um

  1. Colour 1

1) Clour process: Mix Salts

2) Quantity:2 jig(rack)/tank x 1tanks = 2jig(rack)

3) Current density: 70A

4) Process time: 2-8min


6. Sealing
1) Sealing menthod: Sealing at Medium or Normal Temperature
2)
Quantity:6jig(rack)/tank x 1 tank
3) Process time 10-15min


五. Design Parameter and Setting

1. Anodizing treatment area:
1) Each anodizing process tank need 40min ,where total jig(rack)/year:

( 2 rack x 4 tank x 60min/h) ÷40min x600 hour =7200jig(rack)

2) Design 50m²/jig(rack) . Where every tank is 100m²
3)
Area treatment/year : 7200jig(rack)x 50m² /jig =360000m²


2. Anodizing treatment weight:
Monthly output : 360000m²÷350m²/T*0.9=925T≧900T


3. Power consumption:
1) Anodising Tank:100m²/tank* 130A/ m²÷0.9=14444A/tank

Power Rectifier : 15000A =4unit
2) Clouring tank: 100㎡/tank×70A/m²÷0.9 = 7777A/tank

Colour Rectifier : 8000A =2unit


六. Process Chat

Discription for Un
1DeDegreasing
2RsRinsing
3HW RsHot Water Rinsing
4AEAlkaline Etching
5NeNeutralization
6AnAnodizing
7ClColoring
8SlSealing
9MUMaterial Unloading
10PcPacking


China MEIAL 900Ton/M Automatic Anodizing Line Process Operation Type supplier

MEIAL 900Ton/M Automatic Anodizing Line Process Operation Type

Inquiry Cart 0