Add to Cart
low temperature fruit medicine vacuum tray dryer drying equipment
Under normal pressure, pure water starts to boil at 100 C but undervacuum condition, as vapor pressure in the system is lower than thatof material surface, boiling point of water will be lower than 100 C For example, when surface pressure decrease to 0.07Mpa, purewater boil at 70 C So even operate under low temperature condition,such vacuum dryer have strong drying intensity.
1.It can get higher drying capacity at lower temperature and the
heatenergy can be used fully.2.lt is suitable for materials such as
heat sensitive and easyoxidizable material.
3.lt can dry raw materials that contain solvent and which needs to
berecovered.
4.Before drying, it can carry out disinfectant treatment. During
theperiod of drying, any impurity can not enter it.5.The dryer
belongs to static drying, materials will not be damaged.6.The
machine is a kind of batch type operation and can adjusttechnical
process at any time.
7.The inner top is designed arch structure, it can effectively
avoid thecondensed water drop back.
8.Vacuumize from 4 points to one point, can guarantee uniform
drying.
Model Name | YZG-600 | YZG-800 | YZG-1000 | YZG-1400A | FZG-10 | FZG-15 | FZG-20 |
Inter size of drying chamber(mm) | Φ600×976 | Φ800×1247 | Φ1000×1527 | Φ1400×2054 | 1500×1060 ×1220 | 1500×1400 ×1220 | 1500×1800 ×1220 |
Outer size of drying chamber(mm) | 1135×810 ×1024 | 1700×1045 ×1335 | 1693×1190 ×150 | 2386×1675 ×1920 | 1513×1924 ×1720 | 1513×1924 ×2060 | 1513×1924 ×2500 |
Layers of baking support | 4 | 4 | 6 | 8 | 5 | 8 | 12 |
Interval of baking(mm) | 82 | 82 | 102 | 102 | 122 | 122 | 122 |
Size of baking tray(mm) | 310×600 ×45 | 520×410 ×45 | 520×410 ×45 | 460×640 ×45 | 460×640 ×45 | 460×640 ×45 | 460×640 ×45 |
Quantity of baking tray | 4 | 8 | 12 | 32 | 20 | 32 | 48 |
working pressure inside the pipe of baking support(Mpa) | ≤0.784 | ≤0.784 | ≤0.784 | ≤0.784 | ≤0.784 | ≤0.784 | ≤0.784 |
Operation temperature of baking support, oC | 35-150 | 35-150 | 35-150 | 35-150 | 35-150 | 35-150 | 35-150 |
Degree of vacuum inside the chamber when operation (Mpa) | -0.09~0.096 | ||||||
Under the condition of -0.1Mpa and 110oC,evaporation rate of water(kg/m2.hr ) | 7.2 | 7.2 | 7.2 | 7.2 | 7.2 | 7.2 | 7.2 |
When condenser is used,Model,and power of vacuum pump(kw) | 2X-15A 2KW | 2X-30A 3KW | 2X-30A 3KW | 2X-70A 5.5KW | 2X-70A 5.5KW | 2X-70A 5.5KW | 2X-90A 2KW |
When condenser is not used,Model,and power of vacuum pump(kw) | SK-0.8 2.2KW | SK-2.7 4KW | SK-3 5.5KW | SK-6 11KW | SK-3 5.5KW | SK-6 11KW | SK-6 11KW |
Weight of drying chamber(kg ) | 250 | 600 | 800 | 1400 | 1400 | 2100 | 3200 |