VF008 PV System Protection DC Circuit Breaker IEC/EN 60947-2 Standard

Brand Name:HAROK
Model Number:VF008 DC
Minimum Order Quantity:3000
Standard:IEC/EN 60947-2, RoHS
Rated voltage:up to 1000V
Rated current:up to 63A
Contact Now

Add to Cart

Verified Supplier
Address: Liuhuang Road, Liushi Town, Yueqing City, Zhejiang Province
Supplier`s last login times: within 25 hours
Product Details Company Profile
Product Details

VF008 DC Circuit Breaker


1. General

1.1 Standard: IEC/EN 60947-2 ,RoHS;

1.2 Rated voltage up to 1000V, Rated current up to 63A;

1.3 Protection of circuits against overload currents;

1.4 Protection of circuits against short- circuit currents;

1.5 VF008 DC circuit-breakers are used in communication systems and PV DC systems.


2. Features

2.1 Excellent breaking capacity

2.2 Double connection function of lead wire and bus bar

2.3 Stored energy operation, fast closing, long service life

2.4 Convenient installation, disassembly

2.5 Contact on-off indication, higher security

2.6 Green environmental protection and energy saving


3. Operating conditions

3.1 Ambient temperature: -35℃ - + 70℃(Refer to 4.3)

3.2 The atmosphere condition: ≤95%

3.3 Pollution degree: ll

3.4 Altitude: ≤2000m(if exceed 2000m,Refer to 4.4)


4. Technical data

4.1 Classification

4.1.1 Rate Current In:

1A,2A,3A,4A,6A,10A,13A,16A,20A,25A,32A.40A,50A,63A

4.1.2 Number of poles: 1P, 2P, 4P

4.1.3 Tripping curves: C Type, (7-10)In

4.2 Parameters

4.2.1 Rated breaking capacity Icu

Rated current In (A)Number of polesRated voltage Ue (V)Rated breaking capacity Icu (A)
1-6312506000
25006000
410006000

4.2.2 Electrical and mechanical life

a. Electrical life: >1500

b. Mechanical life: >20,000

4.2.3 Rated impulse withstand voltage Uimp: 4KV

4.2.4 (28-32)℃ ambient temperature over-current protection features.

TestTest current

Initial

state

Time limit for tripping or not tripping

Expected

result

Remark
a1.05InCold statet≤1hNot tripping
b1.30InRight after test number at<1hTrippingThe current is rising within 5s
c7InCold statet≤0.2sNot tripping
d10InCold statet<0.1sTripping

Note: The terminology”Cold state”means that the test is performed at the base calibration temperature with no load prior to the test.


4.3 Temperature derating

Rated current (A)Temperature compensation coefficient under various operational temperature.
-35℃-30℃

-20℃


-10℃


0℃


10℃


20℃


30℃


40℃


50℃


60℃


70℃


11.31.261.231.191.151.111.0510.960.930.880.83
22.62.522.462.382.282.22.0821.921.861.761.66
33.93.783.693.573.423.33.1232.882.792.642.49
45.25.044.924.764.564.44.1643.843.763.523.32
67.87.567.387.146.846.66.2465.765.645.284.98
1013.212.712.51211.511.110.6109.69.38.98.4
1317.1616.5116.2515.614.9514.4313.781312.4812.0911.5710.92
1621.1220.482019.218.417.7616.961615.3614.8814.2413.44
2026.425.625242322.221.22019.218.617.816.8
25333231.253028.7527.7526.5252423.2522.2521
3242.5641.284038.7237.1235.5233.933230.7229.7628.1626.88
4053.251.2504846.444.842.44038.437.235.633.6
506765.56360.5585653504846.54441.5
6383.7981.980.0176.8673.7170.5666.786360.4858.955.4452.29

4.4 Altitude derating

Tripping typeRated current In (A)Current correction factorFor example
≤20002000~3000m≥3000m
C

1, 2, 3, 4, 6, 10,

13, 16, 20, 32, 40, 50, 63

10.90.8

Rated current of 10A products rated

current derating 2500m: 0.9×10=9A


4.5 Curves shown in Figure 1

4.6 Wiring: Apply to 25 mm wire connection terminals

Tightening torque 2.5N·m

Rated current In (A)

Copper wire nominal

cross sectional area(mm²)

1~61
101.5
13, 16, 202.5
254
326
40, 5010
6316

4.7 Each pole power consumption of the circuit breaker

Rated current In (A)

Copper wire nominal

cross sectional area(mm²)

1~61
101.5
13, 16, 202.5

4.8 DC application wiring diagram shown in Figure 2

Wiring diagram description:

1. 〇+Positive 〇-Negative

2. L+ Load positive L- Load negative

3. Prohibit power reversed

4. Rated voltage: 1P: 250V, 2P: 500V, 4P: 1000V

5. Strictly forbidden to remove the four poles products of sealing plug wiring operation.


5. Overall and mounting dimensions (mm)


China VF008 PV System Protection DC Circuit Breaker IEC/EN 60947-2 Standard supplier

VF008 PV System Protection DC Circuit Breaker IEC/EN 60947-2 Standard

Inquiry Cart 0