PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated

Brand Name:Victory
Certification:CE,ROHS,ISO 9001
Model Number:K,N,E,J,T,B,R,S Types
Minimum Order Quantity:5
Delivery Time:5-21 days
Payment Terms:L/C, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Changzhou Jiangsu China
Address: NO.32 West Taihu Road, Xinbei District, Changzhou, Jiangsu
Supplier`s last login times: within 22 hours
Product Details Company Profile
Product Details

Thermocouple Extension Wire is a cable designed to extend thermocouple signals and can be used with a variety of thermocouple types, including Type K, Type N, Type E, Type J, Type T, Type B, Type R, and Type S . It provides reliable signal transmission and temperature measurement solutions and is commonly used in industrial control systems, laboratory testing and temperature monitoring applications. Thermocouple Extension Wire has good linear characteristics and anti-interference ability, can accurately transmit the weak voltage signal generated by the thermocouple, and maintain the stability and accuracy of the signal. Whether performing high-temperature furnace control, chemical process monitoring, or laboratory temperature measurement, Thermocouple Extension Wire provides reliable signal transmission to ensure the accuracy and reliability of temperature monitoring systems.


Thermocouple Wire

Code Wires component of the thermocouple
+Positive leg -Negative leg
N Ni-cr-si (NP) Ni-si-magnesium (NN)
K Ni-Cr (KP) Ni-Al(Si) (KN)
E Ni-Cr (EP) Cu-Ni<constantan> (EN)
J Iron (JP) Cu-Ni<constantan> (JN)
T Copper (TP) Cu-Ni<constantan> (TN)

​Standards

ASTM ANSI IEC DIN BS NF JIS GOST
(American Society for Testing and Materials) E 230 (American National Standard Institute) MC 96.1 (European Standard by the International Electrotechnical Commission 584)-1/2/3 (Deutsche Industrie Normen) EN 60584 -1/2 (British Standards) 4937.1041, EN 60584 - 1/2 (Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324 (Japanese Industrial Standards) C 1602 - C 1610 (Unification of the Russian Specifications) 3044

Thermocouple No. indexing Compensation wire type Usag Classification Measuring junction temperature / ℃ standard EMF value/μV Precision grade General grade
Tolerance μV Thermal EMF range μV Tolerance μV Thermal EMF range μV
SorR SC or RC G 100 646 ±30 616~676 ±60 586~706
H 100 646 - - ±60 586~706
200 1 1441 - - 1.381~1 501
K KX,KCA G -25 -968 ±40 -924~-1 012 ±80 -880~-1 056
or KCB 100 4 096 4 052~4 140 4 008~4 184
H -25 -968 ±40 -924~-1 012 ±88 -880~-1 056
100 4 096 4 052~4 140 4 008~4 184
200 8 138 8 094~8 182 8 050~8 226
N NX or NC G -25 -646 ±43 -603~-689 ±86 -560~-732
100 2 774 2 731~2 817 2 688~2 860
H -25 -646 ±43 -603~-690 ±86 -560~-732
100 2 774 2 731~2 817 2 688~2 860
200 5 913 5 870~5 956 5 827~5 999
E EX G -25 -1 432 ±81 -1 351~-1 513 ±138 -1 294~-1 570
100 6 319 6 238~ 6400 6 181~6 457
H -25 -1 432 ±81 -1 351~- 1513 ±138 -1 294~-1 570
100 6 319 6 238~6 400 6 181~6 457
200 13 421 13 340~13 502 13 283~13 559
J JX G -25 -1 239 ±62 -1 177~-1 301 ±123 -1 116~-1 362
100 5 269 5 207~5 331 5 146~5 392
H -25 -1 239 ±62 - 177~-1 301 ±123 -1 116~-1 362
100 5 269 5 207~5 331 5 146~5 392
200 10 779 10 717~10 841 10 656~10 902
T TX G -25 -940 ±30 -910~-970 ±60 -850~-1 000
100 4 279 4 249~4 309 4 189~4 339
H -25 -940 ±48 -892~-988 ±90 -850~-1 030
100 4 279 4231~4 327 4 189~4 369
200

Calibration of thermocouple
Model number of Compensation cable
Alloy wire name of Compensation cable
S or R
SC or RC
Cu-CuNi
K
KC
Cu-CuNi
KX
NiCr-NiSi
N
NC
Fe-CuNi
NX
NiCrSi-NiSiMg
E
EX
NiCr-CuNi
J
JX
Fe-CuNi
T
TX
Cu-CuNi
PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated

China PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated supplier

PTFE PFA FEP J K T Type Thermocouple Extension Cable Wire Copper Heating Insulated

Inquiry Cart 0