LIRUISI SYSTEM Series Intelligent Micromodule System Room Special
Product introduction:
【LIRUISI-SYSTEM】 series integrated data center adopts modular design, integrates power supply and distribution system, air conditioning system, cabinet system, closed channel system, monitoring system and cabling system, and configures various environmental data sampling sensors, which are uniformly monitored and managed by the eSite cloud map monitoring system to achieve automatic control, intelligent operation and maintenance, and improve the reliability, availability and maintainability of the data center.
Scene application:
Core business equipment rooms such as large-scale data centers and campus data centers are suitable forGovernment, medical, education, finance, telecommunications and other leasing and self-use business.
Power segment range:
The maximum supporting power of a single cabinet is 10kW/cabinet.
【 LIRUISI-SYSTEM】 Technical parameters of intelligent micro-module data center system
Product Items | Main parameters | ||
system | Ruler (width * depth * height) | 3600*L*2600mm(L≤15000mm) | |
IT Rated Power/Cabinet | 3~10kW | ||
end | Automatic translation/manual translation/push-pull | ||
Smart Lighting | LED white light, intelligent control of human body sensing; Intelligent color ambient light, linked with the monitoring system; | ||
ban system | Support face/fingerprint/password/IC and other methods to choose from | ||
ambient temperature | 0-45℃ | ||
Protection class | IP20 | ||
altitude | 1000%, greater than 1000% according to standard derating | ||
Installation method | Direct cement floor installation/overhead floor installation | ||
cabinet | Size (width * depth * height) | 600/800*1200*2000mm | |
Available space | 42U | ||
Incoming mode | Support up/down entry line | ||
power distribution system | distribution cabinet | Input method | Single MCCB/Dual ATS |
grid system | 380/400/415Vac,50/60Hz | ||
Specifications | 63~400A | ||
Lightning protection | B/C grade optional | ||
type | Integrated UPS distribution cabinet/precision distribution cabinet/intelligent cable | ||
UPS | capacity | Built-in maximum 200kVA, external 200kVA or more | |
Input frequency range | 40-70Hz | ||
Output power factor | 1 | ||
battery | Built-in cabinet battery cabinet or external battery cabinet | ||
cooling system | Air conditioning capacity | 12.5~60kW | |
Cooling method | Cold row room | ||
refrigerant | R410A | ||
Monitoring system | Human Machine Interface | 21.5 Touch all-in-one machine | |
System function | WEB remote access/centralized monitoring of power, environment, video, restricted systems/northbound interfaces | ||
Monitoring accessories | Smoke sensor/temperature and humidity sensor/flood sensor/infrared sensor/video surveillance/forbidden system/fire linkage | ||
Alarm method | Email/SMS alarm (optional)/sound and light alarm (optional)/telephone voice (optional)/mobile APP (optional) |