Sheathed XLPE Insulated Cable , Cross Linked Polyethylene Cable 95mm 0.6kv

Brand Name:Green Song
Certification:IEC, ASTM,BS,NF,VDE,NZS,ANSI ,DIN JES,JEC(CSA).
Model Number:Low voltage
Minimum Order Quantity:500m
Delivery Time:As customer request
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Wuhan China
Address: Room 1 Floor 1 Wire and Cable Manufacturing Bare Wire Workshop 1 Wujin Industrial Park, Dongjing Street, Hannan District, Wuhan City
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

  • Sheathed XLPE Insulated Cable Cross Linked Polyethylene Cable 95mm 0.6kvc
  • Application

This product is suitable for power lines with rated voltage of 0.6 / 1kV and below, for power transmission, suitable for laying in hotels, stations, airports, high-rise buildings, chemical industry, petroleum platform, power station, subway, tunnel and other fixed laying places.

  • Cable Performance

The long-term allowable operating temperature of the cable shall not exceed 70℃, and the short-time working temperature shall not over 130℃.

The ambient temperature of the installation should not be lower than 0℃.

Minimum bending radius during cable installation: single-core cable not exceeding 15D (D is cable diameter), multi-core cable not exceeding 12D (D is cable diameter)

3. Cable Construction

3.1 Conductor adopts a compact fan or compact round structure, VV 32 is copper conductor and VLV 32 is aluminum conductor.

3.2 70℃ PVC insulation material is used for insulation, and the insulation thickness is shown in Table 1.


Table 1

Nominal section mm2Nominal insulation thickness mmNominal section mm2Nominal insulation thickness mm
1.5 2.50.81501.8
4 61.01852.0
10 161.02402.2
25 351.23002.4
50 701.44002.6
95 1201.6

3.3 Cable armored material: galvanized steel wire is used, and the single core cable used for AC system adopts non-magnetic armored material.

3.4 The sheath is made of 70℃ PVC sheath material.

3.5 Nominal diameter and weight


Table 2

specifications

Core * section

Nominal

outer diameter mm

Nominal Weight kg/kmSpecification Core*sectionOuter Diameter mmNominal weight kg/km
VV32VLV32VV32VLV32
1*1.510.82232092*1.513.8361343
1*2.511.22452252*2.514.6408378
1*412.12902602*417.2623575
1*612.63252832*618.3707635
1*1013.63953282*1020.3879757
1*1614.64813782*1622.81173980
1*2516.26224622*2526.015281220
1*3517.98656462*3527.717921368
1*5019.610557602*5033.025411967
1*7021.313128912*7037.033032475
1*9524.0178812042*9541.341322980
1*12025.4207513432*12045.351903739
1*15028.0246415572*15050.161964395
1*18530.1291617852*18554.373085058
1*24032.9360521092*24060.390496066
1*30036.9463727602*30065.9107957046
1*40040.5564132502*40074.2139779194
3*1.514.34003714*1.515.1446408
3*2.516.05675214*2.516.9634573
3*417.97026304*419.0798701
3*619.08087014*620.3930786
3*1021.310268444*1023.513291085
3*1624.1142611354*1625.916791291
3*2527.6189014294*2529.922671653
3*3529.5225716214*3532.027391891
3*5034.7312922684*5037.738692721
3*7038.5405028084*7042.049503294
3*9543.2515034234*9548.768264523
3*12047.9653743614*12052.380445142
3*15052.5776750654*15058.196776075
3*18557.7932459494*18563.7116607160
3*24064.21165671804*24070.4145588591
3*30070.21401583924*30079.01857811081
3*40079.618222110484*40087.22274013174
3*2.5+1*1.515.85014463*2.5+2*1.517.4668603
3*4+1*2.518.57576693*4+2*2.519.3823720
3*6+1*420.08977653*6+2*421.0996840
3*10+1*622.8125710383*10+2*624.013861132
3*16+1*1025.3159112403*16+2*1026.717781366
3*25+1*1628.9211715603*25+2*1630.623801725
3*35+1*1630.4246817353*35+2*1632.027231893
3*50+1*2536.1346924543*50+2*2538.739992830
3*70+1*3539.9447430203*70+2*3542.550303364
3*95+1*5044.8572437093*95+2*5049.569344633
3*120+1*7050.1737147813*120+2*7053.883875382
3*150+1*7054.6859954833*150+2*7057.395145985
3*185+1*9560.21046965193*185+2*9563.5117127186
3*240+1*12066.21307878783*240+2*12069.6145868660
3*300+1*15072.51560190773*300+2*15078.21842010995
3*400+1*18582.020191118913*400+2*18585.82237512950
4*2.5+1*1.517.76886175*1.516.8601563
4*4+1*2.519.78627505*2.517.9697630
4*6+1*421.310288605*420.2889779
4*10+1*624.5145511765*621.61046878
4*16+1*1027.3186314155*1025.115081218
4*25+1*1631.5252618155*1627.819291461
4*35+1*1634.7326123165*2532.426491900
4*50+1*2540.1431830165*3536.035112472
4*70+1*3544.5549636275*5041.646303195
3*95+1*5051.6757249825*7048.064214351
4*120+1*7055.8904857325*9553.782005321
4*150+1*7060.81064566285*12057.896956068
4*185+1*9566.61287978035*15063.9116887186
4*240+1*12073.41622295305*18569.7140288403
4*300+1*15082.420429120315*24079.01858211123
3*400+1*18590.524923142315*30086.52241413041
5*40096.12762915672

4. Main performance

4.1 The DC resistance of 20℃ conductor shall meet the requirements of Table 3.

Table 3

nominal cross mm21.52.5461016253550
20℃ conductor DC resistance is not over n (Ω / km)copper12.17.414.613.081.831.170.7270.5270.387
aluminium12.47.414.613.081.911.200.8680.641
nominal cross mm27095120150185240300400
20℃ conductor DC resistance is over (Ω / km)copper0.2680.1930.1530.1240.09910.07540.06010.0470
aluminium0.4430.3200.2530.2060.1640.1250.1000.0778

4.2 Finished cable shall be subjected to 3.5kV / 5min voltage test without breakdown.


China Sheathed XLPE Insulated Cable , Cross Linked Polyethylene Cable 95mm 0.6kv supplier

Sheathed XLPE Insulated Cable , Cross Linked Polyethylene Cable 95mm 0.6kv

Inquiry Cart 0