FM200 Automated Fire Extinguishing System No Residue For Telecommunication Room

Brand Name:Air Giant
Certification:UL(Urldorwri1er Laboratories Irlc);TPED;GB;DOT
Model Number:AG227SP-16.6;AG227SP-28.3;AG227SP-40;AG227SP-49;AG227SP-52;AG227SP-50;AG227SP-60;AG227SP-70;AG227SP-80;AG227SP-90;AG227SP-100;AG227SP-120;AG227SP-150;AG227SP-103;AG227SP-147;AG227SP-153;AG227SP-160;AG227SP-170
Minimum Order Quantity:1 set
Delivery Time:10-15 working days
Payment Terms:L/C, D/P, T/T, Western Union, Paypal, Credit card
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou China
Address: Factory 101, Building 2, No. 2, Shaxing Road, Lanhe Town, Nansha District, Guangzhou,China
Supplier`s last login times: within 12 hours
Product Details Company Profile
Product Details

UL Certification Automated Fire Extinguishing System With No Residue For The Telecommunication Room Of FM200

Description of UL FM200 Fire Suppression System

Heptafluoropropane (HFC-227ea) is a clean and safe fire extinguishing agent that can be used in fully submerged automatic fire extinguishing systems, replacing Halon 1301, and maintaining the excellent fire extinguishing performance of Halon fire extinguishing agent without causing any environmental problems


The safety of the heptafluoropropane (HFC-227ea) fire extinguishing system in total flooding applications is safer than Halon 1301, with a safe exposure concentration of 9% accepted by the US Environmental Protection Agency (EPA). Meanwhile, the ozone depletion value (ODP) of HFC-227ea is 0, non-conductive, clean, and residue free.



Attributes of UL GB series cylinders


Material

HP345

C: ≤0.20%

Mn: ≤1.50%

Si: ≤0.35%

P: ≤0.025%

S: ≤0.015%

Al((Acid solubility)): ≥0.015

Working pressure53 bar
Air tightness test pressure80 bar
Burst pressure0 °C ~ 50 °C
Operating temperature rangeRed polyester powder spraying
Surface PaintGB



Features of UL FM200 Fire Suppression System

  • Toxicity

In tests, the acute toxicity of HFC-227EA Agent was shown to be equivalent to that of Halon 1301. HFC-227EA Agent has been evaluated for cardiac sensitization through test protocols approved by the US EPA. The EPA’s SNAP Program classifies HFC-227EA Agent as acceptable for use as a total flooding agent in occupied spaces. Refer to the SNAP program rules for more information.

  • Cleanliness

HFC-227EA Agent is clean, leaves no residue, thereby eliminating costly after-fire clean-up, and keeping expensive “down-time” to a minimum. Most materials such as steel, stainless steel, aluminum, brass, and other metals as well as plastics ,rubber and electronic components are unaffected by exposure to FM-200 Agent.


Application of UL FM200 Fire Suppression System

  • Bank vault
  • Laboratory
  • Rare Book Library
  • Electronic data room
  • Telecom switching room
  • Studio
  • Communication Center
  • Transformer room and distribution room
  • Electrical control room
  • Auxiliary power room
  • Combustible liquid storage room
  • Computer room


Packages of UL FM200 Fire Suppression System
We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.

China FM200 Automated Fire Extinguishing System No Residue For Telecommunication Room supplier

FM200 Automated Fire Extinguishing System No Residue For Telecommunication Room

Inquiry Cart 0