Argon IG541 Inert Gas Fire Suppression System Electrical Automatic Start Mode -10°C To 50°C

Brand Name:Air Giant
Certification:CAL,CMA,CNAS,ILAC-MRA,CCC
Model Number:HMP20/80;HMP30/80;HMP20/140;HMP30140
Minimum Order Quantity:1 set
Delivery Time:10-15 working days
Payment Terms:L/C, D/P, T/T, Western Union, Paypal, Credit card
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou China
Address: Factory 101, Building 2, No. 2, Shaxing Road, Lanhe Town, Nansha District, Guangzhou,China
Supplier`s last login times: within 12 hours
Product Details Company Profile
Product Details

Argon IG541 Inert Gas Fire Suppression System Electrical Automatic Start Mode -10°C To 50°C

Product Description:

IG-541 fire extinguishing agent is a mixture of nitrogen, argon, and carbon dioxide in a specific mass ratio. Common ratios are as follows:


Nitrogen (N2): approximately 48.8% to 55.2% (some sources also show it to be about 50% or 52%)

Argon (Ar): approximately 37.2% to 42.8% (some sources also show it to be about 40% or 42%)

Carbon dioxide (CO2): approximately 7.6% to 8.4% (some sources also show it to be about 8%)


These gases are naturally present in the atmosphere and have abundant sources. They do not cause environmental pollution.

Features:

  1. Environmental Friendliness: IG-541 fire extinguishing agent does not deplete the ozone layer in the atmosphere (Ozone Depletion Potential ODP = 0), and it does not have an impact on the earth's "greenhouse effect," making it a green fire extinguishing agent.
  2. Safety: The extinguishing agent is non-toxic, colorless, odorless, non-corrosive, and non-conductive, neither supporting combustion nor reacting with most substances. In the range of the fire extinguishing design concentration (usually 37%-43%), short-term occupancy by personnel will not cause physiological effects.
  3. Efficiency: The fire extinguishing mechanism is a physical extinguishing method, by lowering the oxygen concentration in the protected area (from the normal air oxygen content of 21% to 12.5% or below), so that it cannot maintain combustion and achieve the purpose of extinguishing fires.
  4. Wide Applicability: It is mainly suitable for computer rooms, communication rooms, power distribution rooms, oil-immersed transformers, standby generators, libraries, archives, museums, and ticket, cultural relics and document storage rooms, etc., where people often work, and can be used to extinguish electrical fires, liquid fires or soluble solid fires, etc.

Technical Parameters:

No.SpecificationTechnical Parameter
1Working Pressure20MPa30MPa
2Device ModelHMP20/80HMP20/140HMP30/80HMP30/140
3Capacity80Ltr140Ltr80Ltr140Ltr
4Filling Capacity of Gas23.9kg42kg33.2kg58.2kg
5Outside Diameter of CylinderΦ279mmΦ406mmΦ267mmΦ356mm
6Height of Cylinder1710mm1460mm1870mm1925mm
7Spraying Time≤120s
8Filling Rate0.299kg/L0.300kg/L0.415kg/L0.201kg/L
9PowerDC24V/1.6A
10Nitrogen Pressure of Driving Device6.0±1.0Mpa(20℃)
11Condition of Reserving Room for Containertemperature: -20~50℃
12Max Working Pressure23.2MPa36.6MPa
13Min Working Pressure18MPa27MPa

Applications:

  1. Data centers and computer rooms: Data centers and computer rooms are key areas where large amounts of electronic equipment are stored, which are very sensitive to fire and can result in data loss and damage to equipment.
  2. Telecommunications and communication rooms: Similar to data centers, telecommunications and communication rooms also contain a large number of expensive electronic equipment and wiring, which are highly sensitive to fire.
  3. Electrical control rooms: Electrical control rooms usually contain a large number of electrical equipment and control systems, which can cause more serious consequences in a fire.
  4. Libraries and archives: Libraries and archives contain a large number of paper documents and archives, which are very sensitive to fire damage.
  5. Museums and art galleries: The artifacts and works of art displayed in museums and art galleries are often of high historical, cultural and artistic value. These items are extremely vulnerable in a fire, so a fire extinguishing system that is both efficient and harmless is needed.
  6. Financial data centers and vaults: Financial data centers and vaults hold large amounts of important data, documents, and valuables. These areas require a reliable fire suppression system to protect them from the threat of fire.
  7. Hospitals and medical facilities: Hospitals and medical facilities contain a large amount of medical equipment and medicines, which can be severely damaged in a fire. In addition, hospitals need to ensure that there is no harm to patients and medical staff during the fire fighting process.
  8. Energy facilities: such as oil-immersed transformer room, power distribution room and other energy facilities are also the suitable places for IG-541 fire extinguishing system. Once the equipment in these facilities catches fire, it may lead to serious fire accidents or even cause explosions.
  9. Precision instruments and laboratories: Precision instruments and laboratories store a large number of expensive experimental equipment and precision instruments. These devices are highly sensitive to fire and will cause huge economic losses in case of fire.
  10. Other places that need efficient fire protection: such as archives, bill repositories, cultural relics repositories, etc., these places also have high fire prevention requirements, and IG541 fire products are also applicable.

Packing and Shipping:

Packaging and Shipping for Inert Gas Fire Suppression System

Our Inert Gas Fire Suppression System is safely and securely packaged in our own custom designed crates in order to ensure that the system arrives in perfect condition. Our custom crates are designed to protect the system from all types of shipping impacts, such as vibration, shock, and extreme temperatures. All of our packaging materials are also optimized for air, land, and sea shipments, so you can be sure that your system will arrive safely no matter what type of shipping you use.

China Argon IG541 Inert Gas Fire Suppression System Electrical Automatic Start Mode -10°C To 50°C supplier

Argon IG541 Inert Gas Fire Suppression System Electrical Automatic Start Mode -10°C To 50°C

Inquiry Cart 0