16-100A Electromagnetic Circuit Breaker RCBO 6kA 230V 400V

Brand Name:YOKG
Certification:CE, KEMA
Model Number:PR8NM
Minimum Order Quantity:100PCS
Delivery Time:15days or Depends on ordering QTYS
Payment Terms:L/C, D/P, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Wenzhou Zhejiang China
Address: Sifang Industrial Park, Beibaixiang Town, YueQing Wenzhou Zhejiang Province China
Supplier`s last login times: within 34 hours
Product Details Company Profile
Product Details

Electromagnetic leakage protector PR8NM 6kA RCBO 16-100A circuit breaker


The Electromagnetic Circuit Breaker Have Following Advatages:

1. Control electric circuits

2. Protect people against indirect contacts and additional protection against direct contacts

3. Protect installations against fire hazard due to insulation faults

4. Residual current circuit breakers are used in housing, tertiary sector and industry

5. Support 35mm Din-rail installation


Tripping sensitivity:

♦ 30 mA--additional protection against direct contact

♦ 100mA--co-ordinated with the earth system according to the formula In<50/R, to provide protection against indirect contacts

♦ 300mA, protection against indirect contacts, as well we fire hazard


Specifications:

Poles2P,4P
Electrical Specification
Rated current (A) In16-100A
Rated working voltage (V) Ue2P:230, 4P:400
Rated insulated voltage (V) Ui500
Impulse withstand voltage (kV) Uimp6
Rated short circuit breaking capacity (kA) Inc/I△n6
Rated residual current (mA) I△n10,30,100,300
Rated residual making and breaking capacity (A) I△m1000
residual current working typeAC,AC+S, A, A+S
residual current protection typeElectromagnetic
Dielectric test voltage(kV)2.5
Service life Mechanical Standard value4000
(O-C) Electrical Standard value2000
Control And indication
Shunt release (SHT)NONE
Undervoltage release (UVT)NONE
Auxiliary contact(AUX)NONE
Contact position indicatorNONE
Fault indicationDEFAULT
Connection And Installation
Ambient temperature (with daily average ≤35℃)-5℃ ~ +40℃
Protection degree All sidesIP40
connection terminalIP20
Wire(m㎡)35
Busbar (m㎡)35
MountingCable/Busbar
Reference temperature for setting of thermal element30
Pollution degree2
Storage temperature(℃)-25℃ ~ +70℃
ConnectionTop
Dimensions(mm) a(2P/4P)36/72
b(2P/4P)84/84
c(2P/4P)79.5/79.5

Selection:

♦ Detectable wave form

♦ AC type

♦ A type

RCCB for which tripping ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowing rising, Symbol



Tripping time:

♦ Instantaneous: Instantaneous tripping can be ensured (without time-delay)

♦ Short time delay : Any tripping can be ensured at least 10ms

♦ Selective : Total discrimination with a nonselective RCD placed downstream are ensured.


Connection Diagram:



The diagram of distribution line:




China 16-100A Electromagnetic Circuit Breaker RCBO 6kA 230V 400V supplier

16-100A Electromagnetic Circuit Breaker RCBO 6kA 230V 400V

Inquiry Cart 0