Add to Cart
High Accuracy Liquid Turbine Flow Meter for Usage in Water, Diesel, Gasoline and other Fluid Measurement
I. Overview
VTF series liquid turbine flowmeters are specially designed for fluid measurement and control systems such as water, diesel and gasoline. They operate according to the turbine principle, which measures the speed at which the impeller rotates in the fluid flow and converts it into a pulse or 4-20mA signal.
2. Product features:
■ The sensor is a hard alloy bearing thrust type, which not only
guarantees accuracy but also improves wear resistance;
■ The structure is simple, firm and easy to disassemble and
assemble;
■ Wide measuring range, low flow rate at the lower limit;
■ Small pressure loss, good repeatability, high accuracy, and the
impeller has anti-corrosion function;
■ Have high anti-electromagnetic interference and anti-vibration
ability;
3. Working principle:
The fluid flows through the sensor housing. Because the blades of
the impeller have a certain angle with the flow direction, the
impulse of the fluid makes the blades have a rotational moment.
After overcoming the friction torque and fluid resistance, the
blades rotate. After the torque is balanced, the speed is stable.
Under certain conditions, The speed is proportional to the flow
rate. Because the blade is magnetically permeable, it is in the
magnetic field of the signal detector (composed of permanent
magnets and coils). The rotating blade cuts the magnetic lines of
force, periodically changing the magnetic flux of the coil, so that
both ends of the coil are changed. The electric pulse signal is
induced, and the signal is amplified and reshaped by the amplifier
to form a continuous rectangular pulse wave with a certain
amplitude, which can be transmitted to the display instrument
remotely to display the instantaneous flow rate and flow rate of
the fluid. Cumulative amount. Within a certain flow range, the
pulse frequency f is proportional to the instantaneous flow Q of
the fluid flowing through the sensor, and the flow equation is:
Q=3600×f/k
Where:
f——pulse frequency [Hz];
k——The meter coefficient of the sensor
Q——The instantaneous flow rate of fluid (under working condition)
[m3/h];
3600-conversion factor;
The meter coefficient of each sensor is filled in the verification
certificate by the manufacturer, and the k value is set in the
matching display instrument to display the instantaneous flow and
cumulative total;
4. Main technical performance:
■ Nominal diameter: DN4-DN200mm
■ Medium temperature: (-20-80)℃, (-20-120)℃, (-20-150)℃;
■ Environmental temperature: (-20-55)℃;
■ Accuracy grade: ±0.2%, ±0.5%, ±1%;
■ Output signal: voltage pulse, 4~20mA two-wire system;
■ Power supply: Sensor: +5V~+24VDC (external) Transmitter: +24VDC
(external), flow meter: 3.0V lithium battery (built-in)
■ Display mode: on-site display, high-definition liquid crystal
display simultaneously displays instantaneous flow (4 significant
digits) and cumulative flow (8 significant digits, with clearing
function). All valid data will be kept for 10 years after power
failure.
■ Body material: 304, 316L;
■ Impeller material: 2Cr13 (titanium-plated treatment, dual-phase
steel)
■ Bearing material: hard alloy;
■ Connection mode: thread, flange, flange clamp, sanitary clamp
interface;
■ Flange Standard: National Standard
■ Working pressure: 1.6~42MPa (10-42MPa high pressure needs to be
customized);
■ Protection level: IP65; explosion-proof level: ExdIICT6Gb;