RF Signal 52 Inch Ceiling Fan Motors BLDC 240V AC PWM Control

Brand Name:Zhaoli
Certification:CE, ROHS, REACH
Model Number:106-15
Minimum Order Quantity:1000
Delivery Time:25-45 days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Zhongshan Guangdong China
Address: No. 10, Fuju Street, Fusha Town, Zhongshan, Guangdong, China 528434
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

BLDC Ceiling Fan Motor For 46inch 52inch Ceiling Fan 240VAC PWM Control RF Signal


Model

Output

signal

Control type

PWM/ voltage

Bearing type

Ball/sleeve bearing

Rated voltage

VDC

Operating voltage

VDC

Rated current

A

Rated input power

W

Speed

RPM

Load

Ceiling fan

Life

hours

D9T92H2B-/PWMBall bearing127.0~13.222426042inch 3 blades30,000
D9T92H4B-/PWMBall bearing2416~26.40.819.223042inch 3 blades30,000
E9T92HBB-/PWMBall bearing240160~2700.23020048inch 3 blades30,000
EBTD0MBB01-FGPWMBall bearing240160~2700.233020052inch 3 blades30,000
EBTD0LAB01-FGPWMBall bearing12090~1500.353517056inch 3 blades30,000
EBTD0LBB01-FGPWMBall bearing240160~2700.254512060inch 3 blades30,000

  • Motor characteristics
Rated voltage240VAC 50/60HZ
Rated speed(on load) 56inch fan230+/-10 RPM
Rated power(on load)38W max
Working dutyS1
Insulation resistance10MΩmin. (500VDC)
Dielectric strength1500VAC/1min leakage current <=5mA
Speed controlPWM
Detecting method of motor speedFG signal

Motor controller (signal receiver)

Colorblack
PowerMotor 40W max
CharacterVector sine wave control
Function

- Through RF(433MHZ) to receive the transmitter signal and control accordingly.

- Motor on and off; Motor on load speed; Motor Running time; Motor rotation direction

Protection Function

- Soft start: When the controller is powered on, the motor will speed up slowly to the required data.

- Over-voltage and under-voltage protection: When the power input to the controller voltage is higher than 270VAC, or less than 70VAC, the controller will turn off the current.

- Over-heating protection: When the temperature is higher than 85℃, the motor is turned off or slow down the speed.

- Lock protection: When the motor suddenly stops due to the external resistance, the controller will turn off the motor current, and try to restart after a few seconds. If there is no resistance, the motor runs normally; if resistance do not disappear, motor will stop running temporarily and after a few cycles, the power would be cut off completely by the controller.

- Over-current protection: Due to external causes, if the motor current increases which exceeds set value, the controller will turn off the motor.

- Constant power protection:The maximum load power of the motor is not affected by the voltage value in the operating voltage range.When the load of the motor changes, the power of the motor remains unchanged.

- Open-phase protection: If there is no power supply to one of the phases, the motor will be stopped running by the controller.


Drawing:

Application: Ceiling fan


China RF Signal 52 Inch Ceiling Fan Motors BLDC 240V AC PWM Control supplier

RF Signal 52 Inch Ceiling Fan Motors BLDC 240V AC PWM Control

Inquiry Cart 0