Add to Cart
CCA Indoor Wiring Unshielded (UTP) 305m Bare Copper Wire 23awg Standard Cat6 Lan cable
▌ Product description
It is applicable to several telecommunication engineering wiring,
indoor (outdoor) telephone communication cables for the connection
between communication systems and floor wiring systems, as well as
the connection between several communication outlets (information
sockets) and telecommunication equipment (such as telephone, fax,
etc.), and shielded cables are used in areas with serious
interference.
For the erection of trunk lines between floors of voice
communication system, it is recommended to use digital
communication cables of large logarithm, which can well meet the
needs of the communication system for the development of digital
transmission broadband communication (such as digital telephone) in
the future.
Multiple pairs of office communication cables are produced with
digital cable standard twisted pair pitch, which reduces the mutual
crosstalk interference between pairs, so as to reduce the crosstalk
attenuation and power loss of cables. It is used for the audio
connection between the main distribution frame in several SPC
switching offices and the users of the switching office, and can
also be used as the audio connection between other switching
equipment, and can support low-speed data transmission. The
connection includes digital telephone, fax, SPC exchange and other
digital equipment for communication. For the connection of branch
lines used for several telecommunication engineering wiring, 10
pairs, 20 pairs, 30 pairs, 50 pairs and 100 pairs are used for the
connection of trunk lines.
▌Construction
▌Standard / Certificate
▌Appliacation
The (indoor) cable is formed by twisted pair and star, which is used for the connection between the floor wiring rack of the telephone communication wiring system and the outlet of the user's telephone residence, as well as the connection between the program-controlled switch and the extension and the interconnection between other communication equipment, and for the telephone, fax, digital telephone and building visual intercom system of the user terminal. Shielded telephone communication cables are used in regional wiring systems with serious environmental interference. (outdoor) cables are mainly used to transmit analog signals with audio frequency of 150kHz and below and digital signals with audio frequency of 2048k bit / s and below.
▌Parameter
REACTION TO FIRE
CHARACTERISTIC | IEC STANDARD | EN STANDARD | CPR RATING |
Classification / EuroClass | - | EN 13501-6 | Cca s1a d1 a1 |
Single Cable Flame Rating | IEC 60332-1-2 | EN 60332-1-2 | Pass |
Smoke Emission | IEC 61034 | EN 61034 | Pass |
Acid Gas Emission | IEC 60754 | EN 60754 | Pass |
PRIMARY ELECTRICAL PARAMETERS
CHARACTERISTIC | SPECIFICATION | TYPICAL PERFORMANCE @ 20°C |
Conductor Loop Resistance | Max 19 Ω/100m | 16 Ω/100m |
Conductor Resistance Unbalance | Max 2% | 0.1% |
Insulation Resistance | >5GΩ.km | >50GΩ.km |
Dielectric Strength | 2500 Vdc/2secs | Pass |
SECONDARY ELECTRICAL PARAMETERS
CHARACTERISTIC | SPECIFICATION | TYPICAL PERFORMANCE @ 20°C |
Velocity of Propagation | <534nsec/100m @ 100MHz | 505nsec/100m @ 100MHz |
Delay Skew | Max 45nsec/100m @100MHz | 30nsec/100m @ 100MHz |
Mean Characteristic Impedance | 100Ω +/- 5Ω @ 100MHz | 100Ω ± 3Ω @ 100MHz |
Transverse Conversion Loss (TCL) | ≥50-10log(f)dB | 61dB @ 10MHz |
ELECTRICAL PERFORMANCE
Frequency (MHz) | 1 | 4 | 10 | 20 | 100 | 200 | 250 | |
Insertion Loss (dB/100m) max | Standard | 2.0 | 3.8 | 6.0 | 8.5 | 19.8 | 29.0 | 32.8 |
NEXT (dB) min | Standard | 74.3 | 65.3 | 59.3 | 54.8 | 44.3 | 39.8 | 38.3 |
PSNEXT (dB) min | Standard | 72.3 | 63.3 | 57.3 | 52.8 | 42.3 | 37.8 | 36.3 |
ACR-F (dB) min | Standard | 67.8 | 55.8 | 47.8 | 41.8 | 27.8 | 21.8 | 19.8 |
PSACR-F (dB) min | Standard | 64.8 | 52.8 | 44.8 | 38.8 | 24.8 | 18.8 | 16.8 |
Return Loss (dB) min | Standard | N/A | 23.0 | 25.0 | 25.0 | 20.1 | 18.0 | 17.3 |
INSTALLATION
Temperature (Installation) | 0°C to +50°C |
Temperature (Operation) | -20°C to +75°C |
Max Tensile Load (Installation) | 10kg |
Segregation Class | Class B |
Min Bend Radius (Installation) | 8 x Outer Diameter |
Min Bend Radius (Operation) | 4 x Outer Diameter |
Field Test NVP Value | 0.66 |
▌STANDARD PACKAGING SPECIFICATIONS – REELS
Part Number | Packaging Length (m) | Color | Nominal Cable Diameter (mm) | Nominal Cable Weight (kg/km) | Reel Size Flange Diameter x Width (mm) | Gross Weight (kg/Item) | Items Per Pallet |
C6U-Cca-500GN | 500 | Green† | 6.15 | 44.9 | 400 x 310 | 24.5 | 18 |
C6U-Cca-1000GN | 1000 | Green† | 6.15 | 44.9 | 465 x 390 | 47.9 | 6 |
▌STANDARD PACKAGING SPECIFICATIONS - BOXES
Part Number | Packaging Length (m) | Color | Nominal Cable Diameter (mm) | Nominal Cable Weight (kg/km) | Box Size L x W x H (mm) | Gross Weight (kg/Item) | Items Per Pallet |
C6U-Cca-Rlx-305GN | 305 | Green† | 6.15 | 44.9 | 435 x 265 x 405 | 14.4 | 21/14†† |
▌Panking
Cable weight | Gross weight | |||||||
9.3kg | 10kg | |||||||
Box size (CM) | Specifications | |||||||
21.5×35×35 | 305m/box |
▌Application scenario
Network TV | Desktop computer | Notebook computer | Printer |
Router | Set top box | Cabinet | Camera |
▌Frequently asked question (FAQ)
Q: Are you a cable and wire manufacturer?
— Yes, we are a professional wire and cable manufacturer.
Q: Can you offer a discount on cables?
— The price is negotiable according to the specification and
quantity.
Q: Can you offer FREE samples?
— Yes,FREE samples are available, you just take care of the freight
fee.
Q: What about your MOQ?
— Usually, our MOQ is 5000 Meters, but we’ d love to talk about
your MOQ.
Q: Do you accept customize cables?
— Yes, we are more than happy to make OEM and ODM for you.
Q: How long is the lead time?
— Usually it’s about 10-14 days.