OFC Fire Rated Power Cable , 8.7-15KV Single Core Power Cable IEC 60502

Brand Name:DONGJIAXIN
Certification:ISO
Model Number:YJV22 8.7/15KV
Minimum Order Quantity:Negotiable
Delivery Time:7-15 working days
Payment Terms:L/C, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: No.8 Huamei Road,Songgang Sub-District,Baoan District, SHENZHEN, Guangdong 518000, China
Supplier`s last login times: within 13 hours
Product Details Company Profile
Product Details

IEC 60502 Single Core Power Cable , 8.7/15 KV XLPE Insulated Power Cable Medium Voltage

1. Construction

ConductorPlain annealed copper wire,solid, Class 1,strand, Class 2,
meets to GB/T 3956, IEC 60228,BS 6360.
Conductor ScreenSemi-conductor (MV only)
InsulationXLPE
Insulation ScreenSemi-conductor (MV only)
Metallic ScreenCopper tape
FillerPP Yarn, or Paper
SeparatorBinding tape
Inner sheathExtruded PVC (MV only)
ArmouringSteel Tape Armoured (STA)
SheathPVC(LSZH)

2. Technical parameters

ross section of conductor(mm²)Conductor structureInsulation thickness(mm)sheath thickness(mm)Approx.cable diameter(mm)Max resistance of conductor at 20℃ (Ω/km)
3×3574.52.651.30.524
3×50104.52.753.80.387
3×70144.52.857.50.268
3×95194.53.062.00.193
3×120244.53.165.20.153
3×150304.53.268.30.124
3×185374.53.372.30.0991

3. Characteristics

  • Rated voltage: 1.8/3kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV
  • Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.
  • Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position
  • Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables
  • 15 x cable O.D for single-core armoured cables
  • 15 x cable O.D for multi-core non-armoured cables
  • 12 x cable O.D for multi-core armoured cables

4. Application

Medium voltage cables for distribution networks; also for connection to generation units and plant and process connection. For installation in ground,in water outdoors, indoors and in cable ducts for power stations, industry, and distribution networks. The water blocking tape avoids propagation inside the cable.


▼ Cable Drum Data:

CABLE DRUMSD1=Flange Diameter(mm)W=Useful Width (mm)D2=Barrel Diameter(mm)
1000700500
1100700550
1200700600
1400750710
1600900900
180011201000
240011501300

▼ Delivery Port :

Port of ShenzhenPort of Hongkong

Port of Guangzhou

▼ CNAS Labortory :

3S Safety Cable Advanced Institute of Technology with 7 laboratories, has been established in Finecredit Group,

including Electrical Performance Laboratory, Mechanical Performance Laboratory, Combustion Test Laboratory,

High Frequency Laboratory, etc. Equipped with over 50 advanced equipment and technologies.

China OFC Fire Rated Power Cable , 8.7-15KV Single Core Power Cable IEC 60502 supplier

OFC Fire Rated Power Cable , 8.7-15KV Single Core Power Cable IEC 60502

Inquiry Cart 0