Cat6 Shielding 8 Core Ethernet Lan Cable For Communication

Brand Name:DONGJIAXIN
Certification:CE ROHS ISO9001
Model Number:Cat 6e
Minimum Order Quantity:Negotiable
Delivery Time:7-15 working days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: No.8 Huamei Road,Songgang Sub-District,Baoan District, SHENZHEN, Guangdong 518000, China
Supplier`s last login times: within 13 hours
Product Details Company Profile
Product Details

Cat 6 shielding communication cable 8 core pure copper conductor network cable of CE RoHS standard

Production Description:

1. Production Parameters:

Conductor material Pure copper, CCA
Conductor diameter Solid one: 0.5mm, 0.56mm, 0.57mm
Stranded one: 23AWG, 24 AWG,28AWG
Num of Conductor 4P
Insulation material PE , HDPE
Insulation diameter 0.9±0.02mm
Jacket material PVC, ROHS PVC, LSZH

Item

(n)

structure

(mm)

Insulation Thickness

(mm)

Approx overall dia.

(mm)

FTP Cat 6 4x0.50 0.98 7.3
FTP Cat 6 4x0.55 1.03 7.4
FTP Cat 6 4x0.57 1.05 7.4

2. Production Features

  • The transmission frequencies of the six types of cables are 1 MHz to 250MHz.
  • The PS-ACR of the six types of cabling systems at 200 MHz should have a large margin, which provides two times the bandwidth of the five types. The transmission performance of the six types of cables is much higher than that of the five types of standards, which is suitable for applications with transmission rates higher than 1 Gbps.
  • Six types of wire are made of 23AWG pure oxygen-free copper as conductor, which has the characteristics of oxidation resistance and long service life.

3. Company Certificates

ISO9001, ISO14001, OHSAS18001, CCC, CE, CB, RoHS, China TOP 100 Enterprises in Cables industry, Guangdong TOP 20 Enterprises in Cables industry and others.

4. Tabular data

Construction

Cat6 Shielding 8 Core Ethernet Lan Cable For Communication 1. Conductor material:

Solid bare copper

0.55mm

2. Insulation material: HDPE
3. sheath material: PVC sheath
4. Shield material AL/TC/AM
5. Cross Separator Environment protection PE
6. Drain wire TC
7. Rip cord: Nylon

Packaging

Approx.Weight Package Package Dimension(cm) Outer packing
16.3 kg 305 m per box 42 x 42 x 24 Carton box

5. Product Image

Cat6 Shielding 8 Core Ethernet Lan Cable For Communication

Cat6 Shielding 8 Core Ethernet Lan Cable For Communication

Cat6 Shielding 8 Core Ethernet Lan Cable For Communication

Product Package

Cat6 Shielding 8 Core Ethernet Lan Cable For Communication

Packging details

– Coil in foil 100m (as of 10 mm2)

– Coil in cardboard (100m) as required (up to 6 mm2)

–Electrical wire ready to delivery

–Reel / Drum (as of 35 mm2)

–Other package as required

Advantage:

Compressed Conductor easy for installation, UV - resistant , total protection for the cable

Standards&Certificates:

IEC 60502-1

Packing&Delivery:

Packaging details : Delivery :
Cat6 Shielding 8 Core Ethernet Lan Cable For Communication Cat6 Shielding 8 Core Ethernet Lan Cable For Communication Cat6 Shielding 8 Core Ethernet Lan Cable For Communication
Steel Wooden Drums Cable Drum In container shipped in 15 days after payment

▼ Cable Drum Data:

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Cat6 Shielding 8 Core Ethernet Lan Cable For Communication 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

▼ Delivery Port :

Cat6 Shielding 8 Core Ethernet Lan Cable For Communication Cat6 Shielding 8 Core Ethernet Lan Cable For Communication Cat6 Shielding 8 Core Ethernet Lan Cable For Communication
Port of Shenzhen Port of Hongkong Port of Guangzhou

▼ Technical parameters:

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 0.7 1.4 6.0 12.1
1×2.5 1 0.7 1.4 6.4 7.41
1×4 1 0.7 1.4 6.9 4.61
1×6 1 0.7 1.4 7.3 3.08
1×10 7 0.7 1.4 8.4 1.83
1×16 7 0.7 1.4 9.4 1.15
1×25 7 0.9 1.4 11.0 0.727
1×35 7 0.9 1.4 12.0 0.524
1×50 10 1.0 1.4 13.3 0.387
1×70 14 1.1 1.4 15.1 0.268
1×95 19 1.1 1.5 17.3 0.193
1×120 24 1.2 1.5 19.0 0.153
1×150 30 1.4 1.6 20.9 0.124
1×185 37 1.6 1.6 23.0 0.0991
1×240 48 1.7 1.7 25.7 0.0754
1×300 61 1.8 1.8 28.3 0.0601
1×400 61 2.0 1.9 31.6 0.0470
1×500 61 2.2 2.0 35.1 0.0366
1×630 61 2.4 2.2 42.1 0.0283

2. 2 Core&3 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 0.7 1.8 10.6 12.1
2×2.5 1 0.7 1.8 11.4 7.41
2×4 1 0.7 1.8 12.4 4.61
2×6 1 0.7 1.8 13.2 3.08
2×10 7 0.7 1.8 15.4 1.83
2×16 7 0.7 1.8 17.4 1.15
2×25 7 0.9 1.8 20.6 0.727
2×35 7 0.9 1.8 22.6 0.524
2×50 10 1.0 1.8 26.2 0.387
2×70 14 1.1 1.8 29.8 0.268
2×95 19 1.1 1.9 34.0 0.193
2×120 24 1.2 2.0 37.4 0.153
2×150 30 1.4 2.2 41.2 0.124
2×185 37 1.6 2.3 45.6 0.0991
2×240 48 1.7 2.5 51.0 0.0754
2×300 61 1.8 2.6 56.0 0.0601
2×400 61 2.0 2.9 62.6 0.0470
2×500 61 2.2 3.1 70.0 0.0366
2×630 61 2.4 3.3 83.6 0.0283
3×1.5 1 0.7 1.8 11.2 12.1
3×2.5 1 0.7 1.8 12.1 7.41
3×4 1 0.7 1.8 13.2 4.61
3×6 1 0.7 1.8 14.0 3.08
3×10 7 0.7 1.8 16.4 1.83
3×16 7 0.7 1.8 18.6 1.15
3×25 7 0.9 1.8 22.0 0.727
3×35 7 0.9 1.8 24.2 0.524
3×50 10 1.0 1.8 28.0 0.387
3×70 14 1.1 1.9 32.1 0.268
3×95 19 1.1 2.0 36.4 0.193
3×120 24 1.2 2.1 40.3 0.153
3×150 30 1.4 2.3 44.3 0.124
3×185 37 1.6 2.4 49.1 0.0991
3×240 48 1.7 2.6 54.9 0.0754
3×300 61 1.8 2.7 60.1 0.0601
3×400 61 2.0 3.0 67.4 0.0470
3×500 61 2.2 3.2 75.3 0.0366
3×630 61 2.4 3.5 90.0 0.0283

3. 4 Core&5 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 0.7 1.8 12.2 12.1
4×2.5 1 0.7 1.8 13.1 7.41
4×4 1 0.7 1.8 14.3 4.61
4×6 1 0.7 1.8 15.3 3.08
4×10 7 0.7 1.8 18.0 1.83
4×16 7 0.7 1.8 20.4 1.15
4×25 7 0.9 1.8 24.3 0.727
4×35 7 0.9 1.8 26.7 0.524
4×50 10 1.0 1.8 30.8 0.387
4×70 14 1.1 2.0 35.4 0.268
4×95 19 1.1 2.1 40.4 0.193
4×120 24 1.2 2.3 44.9 0.153
4×150 30 1.4 2.4 49.3 0.124
4×185 37 1.6 2.6 54.7 0.0991
4×240 48 1.7 2.8 61.0 0.0754
4×300 61 1.8 3.0 67.2 0.0601
4×400 61 2.0 3.3 75.3 0.0470
4×500 61 2.2 3.5 84.0 0.0366
4×630 61 2.4 3.8 100.5 0.0283
5×1.5 1 0.7 1.8 13.2 12.1
5×2.5 1 0.7 1.8 14.2 7.41
5×4 1 0.7 1.8 15.6 4.61
5×6 1 0.7 1.8 16.7 3.08
5×10 7 0.7 1.8 19.6 1.83
5×16 7 0.7 1.8 22.3 1.15
5×25 7 0.9 1.8 26.7 0.727
5×35 7 0.9 1.8 29.4 0.524
5×50 10 1.0 1.9 34.1 0.387
5×70 14 1.1 2.1 39.1 0.268
5×95 19 1.1 2.2 44.7 0.193
5×120 24 1.2 2.4 49.7 0.153
5×150 30 1.4 2.6 54.7 0.124
5×185 37 1.6 2.8 60.6 0.0991
5×240 48 1.7 3.0 67.7 0.0754
5×300 61 1.8 3.2 74.6 0.0601
5×400 61 2.0 3.5 83.4 0.0470
5×500 61 2.2 3.8 93.4 0.0366
5×630 61 2.4 4.1 111.7 0.0283

4. 3+1 Core & 3+2 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 0.7 1.8 12.9 7.41
3×4+1×2.5 1 0.7 1.8 14.0 4.61
3×6+1×4 1 0.7 1.8 15.1 3.08
3×10+1×6 7 0.7 1.8 17.3 1.83
3×16+1×10 7 0.7 1.8 19.8 1.15
3×25+1×16 7 0.9 1.8 23.3 0.727
3×35+1×16 7 0.9 1.8 25.1 0.524
3×50+1×25 10 1.0 1.8 29.4 0.387
3×70+1×35 14 1.1 1.9 33.5 0.268
3×95+1×50 19 1.1 2.1 38.1 0.193
3×120+1×70 24 1.2 2.2 42.5 0.153
3×150+1×70 30 1.4 2.3 45.8 0.124
3×185+1×95 37 1.6 2.5 51.2 0.0991
3×240+1×120 48 1.7 2.6 57.0 0.0754
3×300+1×150 61 1.8 2.8 62.6 0.0601
3×400+1×185 61 2.0 3.1 70.1 0.0470
3×500+1×240 61 2.2 3.3 78.3 0.0366
3×630+1×300 61 2.4 3.6 92.1 0.0283
3×2.5+2×1.5 1 0.7 1.8 13.8 7.41
3×4+2×2.5 1 0.7 1.8 15.1 4.61
3×6+2×4 1 0.7 1.8 16.2 3.08
3×10+2×6 7 0.7 1.8 18.5 1.83
3×16+2×10 7 0.7 1.8 21.3 1.15
3×25+2×16 7 0.9 1.8 24.9 0.727
3×35+2×16 7 0.9 1.8 26.6 0.524
3×50+2×25 10 1.0 1.8 31.4 0.387
3×70+2×35 14 1.1 2.0 35.6 0.268
3×95+2×50 19 1.1 2.1 40.4 0.193
3×120+2×70 24 1.2 2.3 45.5 0.153
3×150+2×70 30 1.4 2.4 48.5 0.124
3×185+2×95 37 1.6 2.5 54.2 0.0991
3×240+2×120 48 1.7 2.7 60.3 0.0754
3×300+2×150 61 1.8 2.9 66.5 0.0601
3×400+2×185 61 2.0 3.2 74.3 0.0470
3×500+2×240 61 2.2 3.5 83.1 0.0366
3×630+2×300 61 2.4 3.8 97.0 0.0283

5. 4+1 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×2.5+1×1.5 1 0.7 1.8 14.0 7.41
4×4+1×2.5 1 0.7 1.8 15.3 4.61
4×6+1×4 1 0.7 1.8 16.5 3.08
4×10+1×6 7 0.7 1.8 19.1 1.83
4×16+1×10 7 0.7 1.8 21.8 1.15
4×25+1×16 7 0.9 1.8 25.8 0.727
4×35+1×16 7 0.9 1.8 28.0 0.524
4×50+1×25 10 1.0 1.9 32.8 0.387
4×70+1×35 14 1.1 2.0 37.3 0.268
4×95+1×50 19 1.1 2.2 42.7 0.193
4×120+1×70 24 1.2 2.3 47.5 0.153
4×150+1×70 30 1.4 2.5 51.6 0.124
4×185+1×95 37 1.6 2.6 57.4 0.0991
4×240+1×120 48 1.7 2.9 64.1 0.0754
4×300+1×150 61 1.8 3.1 70.6 0.0601
4×400+1×185 61 2.0 3.4 78.9 0.0470
4×500+1×240 61 2.2 3.6 88.2 0.0366
4×630+1×300 61 2.4 3.9 104.3 0.0283

Company information:

30 years of experience in R & D, production and sales of wire and cable.

Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.

Annual revenue is about 500 million US dollars.

CNAS laboratory, more than 100 testing reports.

Products are widely used in real estate, municipal, industrial support, mobile communications etc

Cat6 Shielding 8 Core Ethernet Lan Cable For Communication

Cat6 Shielding 8 Core Ethernet Lan Cable For Communication


China Cat6 Shielding 8 Core Ethernet Lan Cable For Communication supplier

Cat6 Shielding 8 Core Ethernet Lan Cable For Communication

Inquiry Cart 0