Add to Cart
Compact Hot Water Chiller with Cool Recovery , Air Cooled Split Unit
Model HLWI~ | 260C | 330C | 380C | 455C | 565C | 655C | 760C | 820C | 910C | ||||||||||
Heating Capacity | ×1000 kcal/h | 221.6 | 281.9 | 326.1 | 390.7 | 485.6 | 563.7 | 652.1 | 707.4 | 781.4 | |||||||||
KW | 257.7 | 327.8 | 379.2 | 454.4 | 564.7 | 655.6 | 758.4 | 822.7 | 908.8 | ||||||||||
Reclaimed Volume | x1000 Kacal/h | 149.9 | 193.9 | 224.2 | 267.2 | 329.3 | 387.8 | 448.5 | 485.3 | 534.3 | |||||||||
KW | 174.3 | 225.5 | 260.8 | 310.7 | 383 | 451 | 521.6 | 564.4 | 621.4 | ||||||||||
Capacity Control (%) | 0, 50, 75, 100 | 0, 25, 37.5, 50, 62.5, 75, 87.5, 100 | |||||||||||||||||
Number of Refrigeration Circuit | 1 | 2 | |||||||||||||||||
Power Supply | 380V/ 3ph/ 50Hz | ||||||||||||||||||
Protection Device | Phase reversion protection, Phase lack protection, Overload current protection, Leakage current protection, Low & High pressure protection, Hi temp. protection, Water flow protection. | ||||||||||||||||||
Total Input (KW) | 78.5 | 94.1 | 107.4 | 134.7 | 164.6 | 188.2 | 214.8 | 245.4 | 269.4 | ||||||||||
Compressor | Type | Semi-hermetic Screw Type | |||||||||||||||||
Power (KW) | 68.9 | 84.5 | 97.8 | 118.7 | 75.1x2 | 84.5X2 | 97.8X2 | 106.7X2 | 118.7X2 | ||||||||||
Fan | Type | Axial Flow | |||||||||||||||||
AirmFlow x1000m³/h | 124 | 115.2 | 115.2 | 160.8 | 172.8 | 230.4 | 230.4 | 321.6 | 321.6 | ||||||||||
Power (KW) | 1.2X8 | 1.2X8 | 1.2X8 | 2.0X8 | 1.2X12 | 1.2X16 | 1.2X16 | 2.0X16 | 2.0X16 | ||||||||||
Evaporator | Ripple Aluminum Fins around Cooper Pipe | ||||||||||||||||||
| Type | Shell and Tube Type | |||||||||||||||||
water side max pressure(MPa) | 1 | ||||||||||||||||||
Dia of Pipe(inch) | 3" | 3" | 4" | 4" | 5" | 3"X2 | 4"X2 | 4"X2 | 4"X2 | ||||||||||
Heat Water Flow (m³/h) | 44.3 | 56.4 | 65.2 | 78.1 | 97.1 | 112.7 | 130.4 | 141.5 | 156.3 | ||||||||||
Drop (kPa) | 53 | 52 | 52 | 50 | 47 | 49 | 50 | 50 | 50 | ||||||||||
Recoverer | Type | Shell and Tube Type | |||||||||||||||||
Water Side Max Pressure (MPa) | 1 | ||||||||||||||||||
Dia.of Pipe (inch) | 3" | 3" | 4" | 4" | 5" | 3"X2 | 4"X2 | 4"X2 | 4"X2 | ||||||||||
Chilled Water Flow(m3/h) | 30 | 38.8 | 44.8 | 53.4 | 65.9 | 77.6 | 89.7 | 97.1 | 106.9 | ||||||||||
Water Pressure Drop (kPa) | 32 | 34 | 45 | 50 | 35 | 38 | 42 | 54 | 54 | ||||||||||
| Type | R22 | |||||||||||||||||
Refrigerant Charge (kg) | 48 | 52 | 56 | 70 | 98 | 104 | 112 | 124 | 140 | ||||||||||
Running Noise dB(A) | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | ||||||||||
Total Weight (Kg) | 2650 | 2760 | 2880 | 3450 | 4950 | 5250 | 5740 | 6300 | 6890 | ||||||||||
Running Weight(Kg) | 3020 | 3140 | 3300 | 3900 | 5370 | 5980 | 6570 | 7160 | 7780 |
1. Designed working condition: DB temp./WB temperature 20℃/15℃; |
2. Hot water inlet/outlet temperature 50℃/55℃; |
Chilled water inlet/outlet temp. 12℃/7℃, Fouling factor: 0.088㎡.°C/KW. |
3. Ambient Temperature 5℃~43℃; |
Please contact manufacture when ambient temperature is lower than 5℃ |
4.Changes of Specification for lmprovement May Be made without Notice. |
Feature:
1 . Cooling Reclaimed Volume : 174.3KW- 621.4KW , Heating Capacity : 257.7 KW - 908.8 KW ;
2 . Compact structure, strong and durable , Compact structure, strong and durable ;
3 . , Hanbell, famous brand compressors are available ;
4 . High efficiency, low noise, low vibration ;
5 . The structure is portable, compact and easy to clean and maintain ;
6. Such air cooled water chiller has been widely used in the central air-conditioning system of hotels, office
buildings,hospitals,shopping malls and other large and medium-sized buildings.
7 . It can be widely used in hotel, office building, school, hospital, factory and other buildings.
8 . High precise control and reliable operation.