Nonpenetrating Trabeculectomy Glaucoma Drainage Implant OEM ODM

Brand Name:Universe
Certification:ISO13485
Model Number:FNPT
Minimum Order Quantity:100 pcs
Delivery Time:30 days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Zhengzhou Henan China
Address: Torch Building A, No. 8 Guohai Ave., Zhengzhou, Henan 450001, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Glaucoma Drainage Implant for Nonpenetrating trabeculectomy


Glaucoma Drainage Implant for nonpenetrating trabeculectomy is produced with Hydrophilic acrylate, which is nontoxic, has no immune response, has good biological compatibility, and cannot be absorbed by tissue. As materials of intraocular lens, it has been clinically applied in ophthalmology for more than ten years,

and is universally accepted as good intraocular implantation material by ophthalmology circle.

Structure and Working Mechanism of Glaucoma Drainage Implant


Glaucoma Drainage Implant for nonpenetrating trabeculectomy has two kinds: type FPT(for penetrating trabeculectomy) and type FNPT(for nonpenetrating trabeculectomy). The overall length of type FNPT is 4.5mm, and the width of slot is 0.7mm. The length of side of type FPT is 3.5mm.There are 4 holes on the Glaucoma Drainage Implant, which used for fixation on sclerotic bed and osmosis of aqueous humor. To implant the Glaucoma Drainage Implant into resected deep sclerotic bed to form a cavity which is called aqueous humor "pond" or "depressurizing room" the upper bottom of linguiform one is exposed to the outside of sclerotic valve, that is made for aqueous humor being drained from the "pond", "cavity" to the underside of conjunctiva, and promoting the formation of new aqueous humor channel, and thus to achieve the goal of reducing intraocular pressure.


Characteristics of Glaucoma Drainage Implant for nonpenetrating trabeculectomy

1. Raw material: Hydrophilic acrylate. .

2. Which has good biological compatibility, and cannot be absorbed by tissue. .

3. Prohibit the growth of fibrocyte, and prevent the formation of filter channel cicatricle. .

4. To impel the formation of new aqueous humor drainage channel. .

5. Distributary of aqueous humor is formed after the implantation of drainage device.

6. It is safe for long-term usage, and intraocular pressure can be effectively controlled. .

7. To increase the success rate and reliability of Glaucoma operation.


Glaucoma Drainage Implant for nonpenetrating trabeculectomy Indication

  1. Primary open angle glaucoma
  2. Partial secondary open angle glaucoma
  3. Primary pupillary block angle-closure glaucoma
  4. Residual glaucoma after peripheral iridectormy
  5. Nonpenetrating Trabeculectory for superior temporal quadrant open angle

China Nonpenetrating Trabeculectomy Glaucoma Drainage Implant OEM ODM supplier

Nonpenetrating Trabeculectomy Glaucoma Drainage Implant OEM ODM

Inquiry Cart 0