Adopt 32-bit DSP (digital signal processor) hardware platform, advanced control algorithm, PG closed loop vector control and sensorless vector control, with both speed vector and torque vector control working methods. It can quickly limit impact current, and could be widely used in high-end manufacturing. This series with high control precision, fast response, superior low frequency characteristic, intelligent detection and protection, has a wide range of network function and friendly user habits, abundant peripheral bus expansion, terminal expansion, relay expansion, analog expansion etc.
Multiple control modes
Including sensorless flux vector control, closed loop vector control and optimized V/F control. It with both speed control and torque control.
Original self-learning function, speed tracking, CANOpen, Profinet, Modubus, free port protocol, local LED single display keyboard, double display keyboard, local LCD keyboard, remote control LCD keyboard
Intelligent protection and detection, with input / output phase loss protection, output phase short circuit protection, output to the ground protection, and abundant peripheral expansion function for bus, terminals, relays, and analog.
VFD500 parameter distribution list
Classification | Parameter group | Page |
Common parameters | 00:Basic function | Page 30 |
01:Frequency source selection | Page 32 | |
02:Start and stop | Page 37 | |
03:Ramp and S curve | Page 39 | |
04: Analog and pulse input | Page 41 | |
05:Analog and pulse output | Page 45 | |
06: Multi-function Digital input (DI) | Page 46 | |
07: Multi-function Digital output(DO) | Page 49 | |
08:Digital Output setting | Page 51 | |
Motor control | 10:Encoder type | Page 53 |
11:Motor1 parmeter | Page 54 | |
12:Motor1 VFcontrol parameter | Page 56 | |
13:Motor1 Vector controlparameter | Page 58 | |
14:Torque control | Page 59 | |
16:Energy saving control | Page 61 | |
Display and protection | 20:User-defined parameters | Page 62 |
21:Keypad and display | Page 63 | |
22:AC Drive configuration | Page 65 | |
23:Drive protection function setting | Page 67 | |
24:Motor protection parameter | Page 70 | |
25:Fault tracking parameter | Page 72 | |
26:Fault recording parameter | Page 72 | |
27:Monitoring parameter | Page 74 | |
Communication | 30:Modbus communication | Page 75 |
Application | 40:Process PID Function | Page 77 |
41:Sleep function | Page 81 | |
42:Simple PLC | Page 82 | |
43:Programmable delay unit | Page 84 | |
44:Comparator and logic unit/controller | Page 86 | |
45:Multifunction counter | Page 90 | |
Motor 2 | 60:Motor2 basic parameter | Page 91 |
61:Motor2 parameter | Page 91 | |
62:Motor2 VF control parameter | Page 92 | |
63:Motor2 vector control parameter | Page 92 |
Techincal Parameters:
Item | Specifiation | |
Input | Inuput Voltage | 1phase/3phase 220V:200V~240V 3 phase 380V-480V:380V~480V |
Allowed Voltage fluctuation range | -15%~10% | |
Input frequency | 50Hz / 60Hz,fluctuation less than 5% | |
Output | Output Voltage | 3phase:0~input voltage |
Overload capacity | General purpose application:60S for 150% of the rated current Light load application:60S for 120% of the rated current | |
Control | Control mode | V/f control Sensorless flux vector control without PG card(SVC) Sensor speed flux vector control with PG card (VC) |
Operating mode | Speed control,Torque control(SVC and VC) | |
Speed range | 1:100 (V/f) 1:200( SVC) 1:1000 (VC) | |
Speed control accuracy | ±0.5% (V/f) ±0.2% (SVC) ±0.02% (VC) | |
Speed response | 5Hz(V/f) 20Hz(SVC) 50Hz(VC) | |
frequency range | 0.00~600.00Hz(V/f) 0.00~200.00Hz(SVC) 0.00~400.00Hz(VC) |
VEIKONG VFD APPLICATION: