VEIKONG VFD500-PV Single Phase Solar Pump Inverter for 220V and 380V Systems with PID Control

Brand Name:VEIKONG
Certification:CE
Model Number:VFD500-PV
Minimum Order Quantity:1
Delivery Time:3 days, depend on the order quantity
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China
Supplier`s last login times: within 20 hours
Product Details Company Profile
Product Details

Single phase three phase 220v to 240v solar pump inverter 2.2kW



VEIKONG VFD500-PV solar pump inverter Features:


1. Power from 220V (0.75 – 75KW) , 380V (0.75 – 160KW)

2. DC/AC Input Compatible, can support DC and AC Input at same time

3. Protection Functions: Over/Under voltage Over-current, Short Circuit, Phase Failure etc

4. Optimized MPPT Arithmetic Accuracy 99%

5. Multi-liquid-level Control, Dry run protection, Wake and Sleep function,,PID control

6. Auto-dormancy on weak light, auto-recovery working on strong light, no need for man-made operations

7. Auto switch over From Solar to Grid Supply with weak light

8. Support optional LCD display and GPRS module.


LCD and GPRS Pictures:


Electrical Specifications and Power degree


PV input
Maxiumum input DC voltage400V DC
Recommended MPPT voltage range250~350V DC
Recommended input Operation Voltage310V DC
Grid or backup generator input
Input voltageSingle phase 220V(-15%~30%)
Output Specification
Rated output voltage3PH 220V
Output frequency0~500.00Hz (default: 0~50.00Hz)
380V Solar Pumping Inverter
Input Specification
PV input
Maxiumum input DC voltage800V DC
Recommended MPPT voltage range450~650V DC
Recommended input Operation voltage540V DC
Grid or backup generator input
Input voltageThree phase 380V(-15%~30%)
Output specification
Rated ouput voltage3PH 380V
Output frequency0~500.00Hz (default: 0~50.00Hz)
Protection
Built-in ProtectionLighting Protection ,over-current, overvoltage, ouput phase lose, under-load, under-voltage, short circuit , overheating, water pump run dry etc.


Product Application

For 220V single phase motor connection

1: Single phase asynchronous motor wiring method (without starting capacitor):

Notice: U is connected to the common end of the starting winding and the working winding, V is connected to the starting winding, and W is connected to the working winding;


Single-phase asynchronous motor if the rotary steering is not correct, you can change the V and W wiring or set P22.13=1.


First solution: Set parameter P11.01=1 (Single phase motor type without capacitor) or second solution: set P00.11=31 if your motor frequency is 50 hz or set P00.11=32 if your motor frequency is 60HZ


For 220V single phase motor connection

2: Single-phase asynchronous motor wiring method (with capacitor)


Notice1: First solution: Connect motor cable to power terminal U and V and enter BSC mode to Set parameter P23.15=0(output phase loss shielding protection) or second solution: set macro P00.11=21 if your motor frequency is 50HZ or set P00.11=22 if your motor frequency is 60HZ


FAQ

1. How to achieve Automatic start after stop?
If it is controlled by keyboard no need to set any parameter. If you want to control by external switch
As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com
and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop
2. How to use a float in the water tank to stop the pump if the tank is full?
If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3
3. How to set minimum frequency ( for example) 30hz and maximum 50HZ
Set P47.05=30HZ and 47.06 to some time and 47.07 to some time. Please refer to details of P47.05-47.07
4. If pump is 60HZ frequency, how to set max frequency?
Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.
Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single
phase with capacitor ,set P00.11=22;If your motor is single phase without capacitor ,set P00.11=32
China VEIKONG VFD500-PV Single Phase Solar Pump Inverter for 220V and 380V Systems with PID Control supplier

VEIKONG VFD500-PV Single Phase Solar Pump Inverter for 220V and 380V Systems with PID Control

Inquiry Cart 0