

Add to Cart
Auto Tuning Variable Frequency Inverters Big Torque In Low
Frequency And Fast Response
1. VFD500 high performance variable frequency inverter product
function and features
1) Deceleration over excitation function. Accurate thermal
simulation platform software ensures the reliability of thermal
simulation.
2) VPowerful internal logic. Built-in up to 6 sets of delay
functions, a wide variety of input sources, the output can be used
as a variety of other built-in module inputs. Support some complex
algorithm.
3) Rich expansion function. Standard ModbusRTU communication
function, support for fieldbus such as Profibus-DP, CanOpen, etc.
Supports incremental encoders and resolvers, where incremental
encoders are compatible with differential encoders and open
collector encoders. Support for IO expansion.
2. Veikong VFD data sheet compare with other products
Other famous brand in China | Veikong | ||
Performance | Overload Capability | G Type: 150% of rated current:1 minute P Type: 120% of rated current: 1 minute 180% of rated current:10 seconds 200% of rated current:1 second | General purpose application:60S for 150% of the rated current Light load application:60S for 120% of the rated current Heavy load overload capability: 110% rated current for long-term stable operation 150% rated current for 1 minute 180% rated current 10s |
Control Mode | SVPWM, SVC | V/f control Sensorless flux vector control without PG card(SVC) Sensor speed flux vector control with PG card (VC) | |
Speed Control Range | Asynchronous motor 1:200(SVC) | 1:100 (V/f) 1:200( SVC) 1:1000 (VC) | |
Starting Torque | Asynchronous motor: 0.5Hz/150%(SVC) | 150%/0.5Hz(V/f) 180%/0.25Hz(SVC) 200%/0Hz(VC) | |
Torque control accuracy | ±0.2%(SVC) | SVC:within 5Hz10%,above 5Hz5% VC:3.0% | |
Frequency Range | Standard:0~400Hz;(380V Goodrive310 special inverters for medium-frequency:0~3200Hz) | 0.00~600.00Hz(V/f) 0.00~200.00Hz(SVC) 0.00~400.00Hz(VC) |
3. Veikong VFD500 series wide applications in different industries
4. Veikong product brochure and user manual download center
VEIKONG VFD500 high performance vector and torque ...
veikong catalog latest.pdf
5. Motor Wiring
◆ It is forbidden to short circuit or ground the inverter output
terminal, otherwise the internal components of the inverter will be
damaged.
◆ Avoid short circuit the output cables or with the inverter
enclosure, otherwise there exists the danger of electric shock.
◆ It is forbidden to connect the output terminal of the inverter to
the capacitor or LC/RC noise filter with phase lead, otherwise, the
internal components of the inverter may be damaged.
◆ When contactor is installed between the inverter and the motor,
it is forbidden to switch on/off the contactor during the running
of the inverter, otherwise, there will be large current flowing
into the inverter, triggering the inverter protection action.
◆ Length of cable between the inverter and motor If the cable
between the inverter and the motor is too long, the higher harmonic
leakage current of the output end will produce by adverse impact on
the inverter and the peripheral devices. It is suggested that when
the motor cable is longer than 100m, output AC reactor be
installed. Refer to the following table for the carrier frequency
setting