Add to Cart
Special VFD high performance frequency inverter for servo motor
High performance
High reliability
User friendly
Product specification
Item | Specification | |
Input | Input voltage | 1phase/3phase 220V:200V-240V 3phase 400V:380V-480V |
Allowed Voltage fluctuation range | -15%~10% | |
Input frequency | 50Hz / 60Hz,fluctuation less than 5% | |
Input filter | SIZE C and above with built in DC reactor | |
Output | Output voltage | 3phase:0~input voltage |
Overload capacity | 150% rated output current for 60s;180% rated output current for 10s;200% rated output current for 2.0s | |
Control | Control mode | V/f control Sensorless vector control (SVC) Vector control with speed sensor (VC) |
Operating mode | Speed control,torque control(SVC ;VC),position servo | |
Speed range | 1:100(V/f) 1:200(SVC) 1:1000(VC) | |
Speed control accuracy | ±0.5%(V/f) ±0.2%(SVC) ±0.01%(VC) | |
Frequency range | 0.00~600.00Hz(standard) 0.0~2000.0Hz(higher standard) | |
Input frequency resolution | Digital input:0.01Hz or 0.01% Analog input:The maximum frequency is 0.025% | |
Startup torque | 150%/0.5Hz(V/f) 180%/0.25Hz(SVC) 180%/0Hz(VC) | |
Torque control accuracy | SVC:5Hz within 8%,5Hz above 5% VC:3.0% | |
Frequency giving ramp | Support linear and S curve acceleration and deceleration; 4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s | |
Position control | The position command supports internal position, pulse position input, CAN open position command, ethercat position command (VFD586). Support position full closed loop mode | |
DC bus voltage control | Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault; Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid skipping the voltage fault; | |
Carrier frequency | 1kHz~16kHz(Varies depending on the type) | |
Startup method | Direct start (can be superimposed DC brake); speed tracking start | |
Stop method | Deceleration stop (can be superimposed DC braking); free to stop | |
Special functions | Built-in delay unit, comparison unit and logic unit, etc., two groups of motor parameter switching, software switching output phase sequence, spindle orientation, online identification of motor parameters |
Item | Specification | |
Function | Keypad | The following three control panels can be configured: LED display(MTBOP1); Shuttle display(MTBOP2); LCD display(MTSOP1) |
Communication | SLOT2 expansion: MODBUS-RTU Communication; CAN open Communication; ProfiNet Communication; thercat communication | |
Encoder interface | Standard: Incremental encoder interface, differential or open collector signal input; differential maximum input 500KHz, open collector maximum input 100KHz; SLOT1 extension: Incremental encoder; Resolver; Sine-cosine encoder; Tamagawa Protocol Absolute Encoder | |
Input terminal | Standard: 7 digital input terminals and one of which supports high-speed pulse input up to 50kHz; 3 analog input terminals,1 support 0 ~ 10V voltage input and 2 support 0 ~ 10V voltage input or 0 ~ 20mA current input 1 motor temperature detection, support PT100, PT1000, KTY84-130 three kinds of thermistor input; SLOT2 extension: 1DI digital terminal input(VFD580-IOEX1) | |
Output terminal | Standard: 2 digital output terminals;1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output; 2 relay output terminals; 2 analog output terminals,1 support 0~10V voltage output,1 support 0~20mA current output or 0~10V voltage output; SLOT2 extension: 2 digital output terminals(VFD580-IOEX1) | |
Protection | Refer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function | |
Environment | Installation location | Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. |
Altitude | 0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m | |
Ambient temperature | -10°C~ +40°C, maximum 50°C (derated if the ambient temperature is between 40°C and 50°C) Rated output current decrease by 1.5% if temperature increase by 1°C | |
Humidity | Less than 95%RH, without condensing | |
Vibration | Less than 5.9 m/s2 (0.5 g) | |
Storage temperature | -20°C ~ +60°C | |
Other | Installation | Wall-mounted, floor-controlled cabinet, transmural |
Through-the-wall (requires optional accessories, see "7.2 Optional accessories for through-wall installation") | ||
Protection level | IP21 | |
Cooling method | Forced air cooling | |
Grid system | TT/TN/IT (VDR and EMC screws must be removed for disconnection to earth for IT grid systems) |
Product picture
FAQ
1. What voltage range can you support?
Single-phase 220v input, single-phase 220v output;
Single-phase 220v input, three-phase 220v output;
Three-phase 220v input, three-phase 220v output;
Single-phase 220v input, three-phase 380v output;
2. What is the standard of package?
Below 37kw, it's carton package; 45kw and above, it's wooden package.
3. Do you accept OEM business?
We accept OEM and ODM with your autherization.