Add to Cart
Energy Saving Heater Air Conditioner Combo Wall Unit 60hz 220V 12000BTU
YC Panel Mini Split AC 60hz 220V R410a/R32 12000BTU Cooling Heating Energy Saving Wifi Control PCB 3 Year Warranty
The structure of the air conditioner includes: compressor, condenser, evaporator, four-way valve, one-way valve capillary assembly, etc.
The ventilation function is the latest technology used in wall-mounted air conditioners to ensure that there is fresh air in the home, prevent the occurrence of air-conditioning diseases, and make it more comfortable and reasonable to use.
In addition, quiet and energy-saving designs are also very important, allowing you to sleep peacefully until dawn. Some wall-mounted air conditioners have ultra-small outdoor units. If you plan to put the outdoor units on the balcony, this is also a good choice.
As for the heating and cooling type wall-mounted air conditioners, attention should be paid to choosing an air conditioner with a heating capacity greater than the cooling capacity to ensure the heating effect. If there is an electric auxiliary heating function, it can be guaranteed to be able to heat in an ultra-low temperature environment (minimum -10 degrees Celsius) (the temperature of the air outlet is above 40 degrees Celsius).
9000BTU | |||
Model No. | YTA-09CH | ||
KFR-25GW | |||
indoor 770(Φ7.94×1)+outdoor700(Φ7.94×1) | |||
Type | Heating Pump | ||
Control type | |||
Rated cooling capacity | Btu/h;W | 8048;2359 | |
Rated heating capacity | Btu/h;W | 8632;2530 | |
EER for cooling | Btu/h.w; W/W | 2.48 | |
COP for heating | W/W | 2.7 | |
Moisture removal | Liters/h | 0.78 | |
Pressure | High(DP) | MPa | 2.8 |
Low(SP) | MPa | 1.2 | |
Indoor noise level at cooling | High | dB(A) | 39 |
Med. | dB(A) | 34 | |
Low | dB(A) | 22 | |
Outdoor noise level | dB(A) | 49 | |
Power supply | |||
Voltage Range | V | 198~242 | |
Rated current | Cooling | A | 4.4 |
Heating | A | 4 | |
Rated input | Cooling | W | 947 |
Heating | W | 936 | |
Annual energy consumption | kwh (cooling) | ||
Max Current | Cooling | A | 7.09 |
Heating | A | N.A | |
Max Power input | Cooling | W | 1337 |
Heating | W | N.A | |
Refrigerant/Charge | Gram | R22 | |
Compressor | Type | Rotary | |
Model | 凌达QX-B160C130 | ||
LRA | A | / | |
MFG | GREE | ||
Indoor air circulation(Cooling/Heating) | m3/h | 430/430 | |
Indoor fan type | Cross flow | ||
Indoor fan speed H/M/L | Cooling | rpm | 1160/1060/900 |
Heating | rpm | 1160/1060/900 | |
Dry | rpm | 900 | |
Sleep | rpm | 900 | |
Indoor fan motor output | W | 8 | |
Outdoor fan type | Propeller | ||
Outdoor fan speed | rpm | 850 | |
Outdoor fan motor output | W | 30 | |
Connecting Pipe | Gas | mm | Φ9 |
Liquid | mm | Φ6 | |
Connecting Wiring | Size x Core number | 5*0.75 | |
Drainage Pipe | |||
Suitable area | m2 | 8~12 | |
Net dimensions (W x H x D) | Indoor | mm | 770x250x205 |
Outdoor | mm | 700x540x255 | |
Net weight | Indoor | kg | 9 |
Outdoor | kg | 30 | |
Packing dimensions (W x H x D) | Indoor | mm | 840*279*325 |
Outdoor | mm | 815*350*600 | |
Gross weight | Indoor | kg | 10 |
Outdoor | kg | 34/35 |
Dehumidification
The air conditioner is accompanied by dehumidification during the refrigeration process. The relative humidity of the environment that people feel comfortable should be around 40-60%. When the relative humidity is too high, such as above 90%, even if the temperature is within a comfortable range, people still feel bad.
Purifying air
The air contains a certain amount of harmful gases such as NH3, SO2, etc., as well as various odors such as sweat, body odor and bathroom odor.
Purification methods for air conditioners include: changing fresh air, filtering, and using activated carbon or photocatalyst to absorb and absorb.