L-HPT Dynamic Pile Load Test Equipment High Strain / Low Strain ASTM D5882 Standard

Brand Name:SAMYON
Certification:ISO
Model Number:L-HPT
Minimum Order Quantity:1 set
Delivery Time:3-5days
Payment Terms:Western Union, MoneyGram, , T/T, D/P, D/A
Contact Now

Add to Cart

Active Member
Location: Beijing Beijing China
Address: Room A-109, No. 54, Shunren Road, Shunyi Dist,Beijing, China 101300
Supplier`s last login times: within 3 hours
Product Details Company Profile
Product Details

L-HPT High strain / Low strain dynamic pile tester


Application: Used for testing the pile loading capacity and the pile integrity and detecting the defect position by dynamic method


Standard:


ASTM D4945-00 “Standard Test Method for High Strain Dynamic Testing of Piles”

ASTM D5882 Standard Test Method for Low Strain Impact Integrity Testing of Deep Foundations


Parameters:


ItemNameHPT detailsLPT details
1Sampling frequency10 kHz, 20 kHz, 30 kHz and 40 kHz48kHz, 96 kHz,144 kHz
2Sampling points1024, 2048 and 40964096
3SoftwarePDAR and RCAPWAP, without key, so it can be installed to any computerLPTR, without key, so it can be installed to any computer
4AccelerometerPE, imported from America0.5~10000Hz, IP68, imported from America,
5Strain gaugeRange 2000
6Main host size225*172*62mm
7Main host weight2.0kg
8Screen8inch high brightness color touchscreen LCD, can be operated by hand or touch pen
9CableSpecial customized for field testing
10Connectoraviation plug and connectors are with high quality, compatible with American machine
11PowerLi battery 12.6V 5200mAh

Technical features for HPT testing:

1. HPT used for determine the pile bearing capacity and pile integrity.

2. It can be used for pile driving monitoring and the cast-in-place pile testing.

3. Sampling frequency is optional of 10 kHz, 20 kHz, 30 kHz and 40 kHz.

4. Sampling points are optional of 1024, 2048 and 4096. Maximum sampling time is up to 400 ms

5. Before testing, the two accelerometers and two strain transducers are self-checked automatically, determine whether the system is in normal state.

6. Automatically check the static strain deviation of the strain transducer during installation and adjust to zero before blow.

7. Test data exported through the external u-disk

8. During test every blow can be saved automatically

9. Storage capacity of more than ten thousands blows.

10. HPT data can save as *.X01 (used for PDA-W)

11. The main cable and connecting cable are compatible with the PDA.

12. Built-in lithium battery can be used more than 6 hours continuously.

13. PDAR program is for CASE method analysis.

14. RCAPWAP program is for match analysis automatically.


Technical features for LPT testing:

1. With the imported accelerometer from America with the high precision

2. 24bit high precision AD resolution

3. Sampling frequency 48kHz,96kHz,144kHz

4. Sampling points 4096

5. For the field data collection, it has average function for multi blows

6. It has auto statistical function for test piles quantity

7. The data can be exported by U disk

8. It has small wave analysis function

9. It can save the data by auto or manual method

10. It can do analysis for index amplification and small wave during testing

11. Built-in lithium battery can be used more than 6 hours continuously.


China L-HPT Dynamic Pile Load Test Equipment High Strain / Low Strain ASTM D5882 Standard supplier